Accuracy assessment of fringe projection profilometry and digital image correlation techniques for three-dimensional shape measurements

被引:0
|
作者
Nguyen, Hieu [1 ,2 ]
Liang, Jiali [3 ]
Wang, Yuzeng [4 ]
Wang, Zhaoyang [2 ]
机构
[1] Neuroimaging Research Branch, National Institute on Drug Abuse, National Institutes of Health, Baltimore,MD,21224, United States
[2] Department of Mechanical Engineering, Catholic University of America, Washington,DC,20064, United States
[3] Department of Astronomy, University of Maryland, College Park,MD,20742, United States
[4] School of Mechanical Engineering, Jinan University, Jinan,250022, China
来源
JPhys Photonics | 2021年 / 3卷 / 01期
关键词
Image acquisition - Image reconstruction - Profilometry - Strain measurement;
D O I
暂无
中图分类号
学科分类号
摘要
With ever-increasing demand for three-dimensional (3D) imaging and shape measurements in a variety of fields, measurement accuracy has become of vital importance to numerous scientific and engineering applications. This paper presents an experimental investigation into the accuracy comparison of two prevalent 3D imaging and shape measurement methods: fringe projection profilometry (FPP) and 3D digital image correlation (3D-DIC) techniques. A detailed description of their principles reveals their inherent similarities and fundamental differences. A measurement system composed of both techniques is employed in the study, and a test target with speckle checkerboard patterns on its surface is adopted to allow simultaneous FPP and 3D-DIC measurements. The evaluation puts emphasis on how the geometric angles between key hardware components affect the 3D measurement accuracy. Experiments show that the depth and height measurements of both techniques can reach sub-micron accuracy, and the relative accuracy of the 3D shape or position measurements can reach 1/600 000. © 2021 The Author(s). Published by IOP Publishing Ltd
引用
收藏
相关论文
共 50 条
  • [1] Accuracy assessment of fringe projection profilometry and digital image correlation techniques for three-dimensional shape measurements
    Hieu Nguyen
    Liang, Jiali
    Wang, Yuzeng
    Wang, Zhaoyang
    JOURNAL OF PHYSICS-PHOTONICS, 2021, 3 (01):
  • [2] Three-Dimensional Shape and Deformation Measurements Based on Fringe Projection Profilometry and Fluorescent Digital Image Correlation via a 3 Charge Coupled Device Camera
    Sun, Wei
    Xu, Zhongda
    Li, Xin
    Chen, Zhenning
    Tang, Xinqiao
    SENSORS, 2023, 23 (15)
  • [3] Refractive fringe projection profilometry for three-dimensional shape measurement
    Chen, Chao
    Li, Zhaonan
    Lu, Wenzhen
    Wang, Yuzhu
    OPTICS LETTERS, 2023, 48 (17) : 4689 - 4692
  • [4] Integration of fringe projection and two-dimensional digital image correlation for three-dimensional displacements measurements
    Felipe-Sese, Luis
    Lopez-Alba, Elias
    Siegmann, Philip
    Diaz, Francisco A.
    OPTICAL ENGINEERING, 2016, 55 (12)
  • [5] Three-dimensional shape measurement with an arbitrarily arranged fringe projection profilometry system
    Du, Hua
    Wang, Zhaoyang
    OPTICS LETTERS, 2007, 32 (16) : 2438 - 2440
  • [6] Fringe Projection Profilometry for Three-Dimensional Measurement of Aerospace Blades
    Chen, Ze
    Zhu, Mulun
    Sun, Chuanzhi
    Liu, Yongmeng
    Tan, Jiubin
    SYMMETRY-BASEL, 2024, 16 (03):
  • [7] Superimposed fringe projection for three-dimensional shape acquisition by image analysis
    Sasso, Marco
    Chiappini, Gianluca
    Palmieri, Giacomo
    Amodio, Dario
    APPLIED OPTICS, 2009, 48 (13) : 2410 - 2420
  • [8] Fringe projection profilometry for the 3D shape measurement of objects with three-dimensional movements
    Duan, Chengpu
    Zhang, Yiwei
    Xi, Jiangtao
    Tong, Jun
    Yu, Yanguang
    Guo, Qinghua
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS VI, 2019, 11189
  • [9] Three-dimensional surface inspection for semiconductor components with fringe projection profilometry
    Deng, Fuqin
    Ding, Yi
    Peng, Kai
    Xi, Jiangtao
    Yin, Yongkai
    Zhu, Ziqi
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS IV, 2016, 10023
  • [10] Comparison of the accuracy of digital stereophotogrammetry and projection moire profilometry for three-dimensional imaging of the face
    Artopoulos, A.
    Buytaert, J. A. N.
    Dirckx, J. J. J.
    Coward, T. J.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 43 (05) : 654 - 662