Existing and Emerging Technologies for Therapeutic Monitoring of Lithium

被引:0
|
作者
Pedraza-Sanabria, Santiago [1 ]
Dodd, Seetal [2 ,3 ,4 ,8 ]
Giraldo-Cadavid, Luis Fernando [4 ,5 ]
Whittingham, Karen [1 ]
Bustos, Rosa-Helena [6 ,7 ]
机构
[1] Univ El Bosque, Dept Psychiat, Bogota, Colombia
[2] Deakin Univ, IMPACT Inst Mental & Phys Hlth & Clin Translat, Sch Med, Geelong, Australia
[3] Univ Melbourne, Ctr Youth Mental Hlth, Parkville, Australia
[4] Univ La Sabana, Fac Med, Chia, Colombia
[5] Fdn Neumol Colombiana, Intervent Pulmonol, Bogota, Colombia
[6] Univ La Sabana, Fac Med, Dept Clin Pharmacol, Evidence Based Therapeut Grp, Campus del Puente del Comun, Chia, Colombia
[7] Clin Univ La Sabana, Chia, Colombia
[8] Univ Hosp Geelong, IMPACT, POB 281, Geelong, Vic 3220, Australia
关键词
lithium; lithium monitoring; therapeutic drug monitoring; point-of-care systems; MICROCHIP CAPILLARY-ELECTROPHORESIS; SERUM; ELECTRODE; SYSTEM;
D O I
10.1097/JCP.0000000000001835
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background/Purpose: Lithium is an effective psychoactive drug. It has a narrow therapeutic margin, with subtherapeutic levels or intoxication commonly occurring. Therapeutic drug monitoring (TDM) of lithium has several barriers. This scoping review aims to describe and analyze existing and emerging technologies for lithium TDM and to describe the lithium quantification parameters (precision, accuracy, detection limit) attributed to each technology. Method: PubMed, Scopus, Web of Science, and Google Scholar were searched. Studies that described lithium quantification and complied with PRISMA-ScR guidelines were included. Articles selection was conducted by 2 researchers. Good precision was defined if its relative standard deviation <3%; acceptable, from 3% to 5%; and low, >5%. Accuracy was considered good if the error <5%; acceptable, 5%1 to 0%; and low if it was >10%. Results: Of the 2008 articles found, 22 met the inclusion criteria. Of these, 14 studies concerned laboratory devices, in which precision was found to be low in one third of cases, and half had good precision. Accuracy of one third was good, another third was low, and the remaining third did not report accuracy. The other 8 studies concerned portable devices, in which precision was low in more than 60% of the cases and good in 25% of the studies. Accuracy was low in 50% of the cases, and good in just over a third. Limits of detection included the therapeutic range of lithium in all studies. Conclusions: Among emerging technologies for lithium TDM, precision and accuracy remain a challenge, particularly for portable devices.
引用
收藏
页码:291 / 296
页数:6
相关论文
共 50 条
  • [1] EMBRACING EXISTING AND EMERGING TECHNOLOGIES
    不详
    [J]. CHEMICAL ENGINEERING, 2013, 120 (06) : 18 - 18
  • [2] Emerging therapeutic drug monitoring technologies: considerations and opportunities in precision medicine
    Liang, Winnie S.
    Beaulieu-Jones, Brett
    Smalley, Susan
    Snyder, Michael
    Goetz, Laura H.
    Schork, Nicholas J.
    [J]. FRONTIERS IN PHARMACOLOGY, 2024, 15
  • [3] A Classification of Existing and Emerging Hydrogen Storage Technologies
    Bosch, Niamh
    Bianchi, Alessio Belmondo
    Torbaghan, Shahab Shariat
    [J]. 2023 IEEE BELGRADE POWERTECH, 2023,
  • [4] Applications of existing and emerging construction safety technologies
    Maali, Omar
    Ko, Chien-Ho
    Nguyen, Phuong H. D.
    [J]. AUTOMATION IN CONSTRUCTION, 2024, 158
  • [5] Existing and Emerging Technologies for Tumor Genomic Profiling
    MacConaill, Laura E.
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2013, 31 (15) : 1815 - 1824
  • [6] Emerging Technologies in Patient Monitoring
    Muehlsteff, Jens
    Ayoola, Idowu
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 : 430 - 430
  • [7] Keeping up with existing and emerging technologies: An introduction to PDAs
    Cassey, Margaret Z.
    [J]. NURSING ECONOMICS, 2007, 25 (02): : 121 - +
  • [8] Emerging monitoring technologies in kidney transplantation
    Abdulla Ehlayel
    K’joy J. A. Simms
    Isa F. Ashoor
    [J]. Pediatric Nephrology, 2021, 36 : 3077 - 3087
  • [9] Emerging monitoring technologies in kidney transplantation
    Ehlayel, Abdulla
    Simms, K'joy J. A.
    Ashoor, Isa F.
    [J]. PEDIATRIC NEPHROLOGY, 2021, 36 (10) : 3077 - 3087
  • [10] Impact of emerging sustainable aircraft technologies on the existing operating ecosystem
    Babuder, Diego
    Lapko, Yulia
    Trucco, Paolo
    Taghavi, Ray
    [J]. JOURNAL OF AIR TRANSPORT MANAGEMENT, 2024, 115