Sagittal and transverse ankle angle coupling can influence prosthetic socket transverse plane moments

被引:0
|
作者
Klute, Glenn K. [1 ,2 ]
Mulcahy, Connor W. [1 ,2 ]
机构
[1] Ctr Limb Loss & Mobil, US Dept Vet Affairs, Seattle, WA 98108 USA
[2] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
来源
关键词
prosthesis; lower limb; amputation; residual limb; torsion adapter; transverse plane rotation adapter; SKIN PROBLEMS; TRANSTIBIAL AMPUTEE; STRAIGHT-LINE; SATISFACTION; WALKING; PAIN; GAIT; MASS; BIOMECHANICS; AMBULATION;
D O I
10.3389/fresc.2024.1354144
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Introduction The intact foot and ankle comprise a complex set of joints that allow rotation in multiple planes of motion. Some of these motions are coupled, meaning rotation in one plane induces motion in another. One such coupling is between the sagittal and transverse planes. For every step, plantar- and dorsi-flexion motion is coupled with external and internal rotation of the shank relative to the foot, respectively. There is no prosthetic foot available for prescription that mimics this natural coupling. The purpose of this study was to determine if a sagittal:transverse ankle angle coupling ratio exists that minimizes the peak transverse plane moment during prosthetic limb stance. Methods A novel, torsionally active prosthesis (TAP) was used to couple sagittal and transverse plane motions using a 60-watt motor. An embedded controller generated transverse plane rotation trajectories proportional to sagittal plane ankle angles corresponding to sagittal:transverse coupling ratios of 1:0 (rigid coupling analogous to the standard-of-care), 6:1, 4:1, 3:1, and 2:1. Individuals with unilateral transtibial amputation were block randomized to walk in a straight line and in both directions around a 2 m circle at their self-selected speed with the TAP set at randomized coupling ratios. The primary outcome was the peak transverse plane moment, normalized to body mass, during prosthetic limb stance. Secondary outcomes included gait biomechanic metrics and a measure of satisfaction. Results Eleven individuals with unilateral transtibial amputations participated in the study. The 6:1 coupling ratio resulted in reduced peak transverse plane moments in pairwise comparisons with 3:1 and 2:1 coupling ratios while walking in a straight line and with the prosthesis on the outside of the circle (p < .05). Coupling ratio had no effect on gait biomechanic metrics or satisfaction. Discussion The general pattern of results suggests a quadratic relationship between the peak transverse plane moment and coupling ratio with a minimum at the 6:1 coupling ratio. The coupling ratio did not appear to adversely affect propulsion or body support. Subjects indicated they found all coupling ratios to be comfortable. While a mechatronic prosthesis like the TAP may have limited commercial potential, our future work includes testing a robust, passive prosthetic foot with a fixed coupling ratio.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Transverse plane motion at the ankle joint
    Nester, CJ
    Findlow, AF
    Bowker, P
    Bowden, PD
    FOOT & ANKLE INTERNATIONAL, 2003, 24 (02) : 164 - 168
  • [2] The effect of transverse prosthetic alignment changes on socket reaction moments during gait in individuals with transtibial amputation
    Hashimoto, Hiroshi
    Kobayashi, Toshiki
    Gao, Fan
    Kataoka, Masataka
    Orendurff, Michael S.
    Okuda, Kuniharu
    GAIT & POSTURE, 2018, 65 : 8 - 14
  • [3] Influence of coronal and sagittal prosthetic foot alignment on socket reaction moments in transtibial prostheses during walking
    Hashimoto, Hiroshi
    Kobayashi, Toshiki
    Kataoka, Masataka
    Okuda, Kuniharu
    GAIT & POSTURE, 2021, 90 : 252 - 260
  • [4] Sagittal plane pelvis motion influences transverse plane motion of the femur: Kinematic coupling at the hip joint
    Bagwell, Jennifer J.
    Fukuda, Thiago Y.
    Powers, Christopher M.
    GAIT & POSTURE, 2016, 43 : 120 - 124
  • [5] A Mechanical Model of the Human Ankle in the Transverse Plane During Straight Walking: Implications for Prosthetic Design
    Glaister, Brian C.
    Schoen, Jason A.
    Orendurff, Michael S.
    Klute, Glenn K.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (03):
  • [6] Mechanical behavior of the human ankle in the transverse plane while turning
    Glaister, Brian C.
    Schoen, Jason A.
    Orendurff, Michael S.
    Klute, Glenn K.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2007, 15 (04) : 552 - 559
  • [7] Alignment in the transverse plane, but not sagittal or coronal plane, affects the risk of recurrent patella dislocation
    Takagi, Shigeru
    Sato, Takashi
    Watanabe, Satoshi
    Tanifuji, Osamu
    Mochizuki, Tomoharu
    Omori, Go
    Endo, Naoto
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (10) : 2891 - 2898
  • [8] Alignment in the transverse plane, but not sagittal or coronal plane, affects the risk of recurrent patella dislocation
    Shigeru Takagi
    Takashi Sato
    Satoshi Watanabe
    Osamu Tanifuji
    Tomoharu Mochizuki
    Go Omori
    Naoto Endo
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 2891 - 2898
  • [9] Sagittal plane position of the functional joint centre of prosthetic foot/ankle mechanisms
    Rusaw, David
    Ramstrand, Nerrolyn
    CLINICAL BIOMECHANICS, 2010, 25 (07) : 713 - 720
  • [10] Correction to: Alignment in the transverse plane, but not sagittal or coronal plane, affects the risk of recurrent patella dislocation
    Shigeru Takagi
    Takashi Sato
    Satoshi Watanabe
    Osamu Tanifuji
    Tomoharu Mochizuki
    Go Omori
    Naoto Endo
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 2219 - 2219