Uniform circular multiphase modulation correlation radiometer and its sensitivity analysis

被引:0
|
作者
Chen R. [1 ]
Luo J. [1 ]
Hu A. [1 ]
Miao J. [1 ]
机构
[1] School of Electronic Information Engineering, Beihang University, Beijing
基金
中国国家自然科学基金;
关键词
correlation radiometer; least squares fitting; multiphase modulation; radiometry; sensitivity;
D O I
10.13700/j.bh.1001-5965.2021.0560
中图分类号
学科分类号
摘要
A correlation radiometer structure with uniform multiphase modulation around the circumference is proposed in order to address the issue of decreased measurement accuracy caused by the operational amplifier’s offset drift and gain fluctuation in correlation radiometers. The measurement result is processed using the least square fitting method, which removes the influence of the operational amplifier’s offset drift on the measurement deviation. Based on the structure of the correlation radiometer and the noise statistical model, the expression of the temperature sensitivity of the uniform circular multiphase modulation correlation radiometer is computed, and the relationship between the system sensitivity and phase modulation order, gain fluctuation and phase shift error is analyzed. The analysis shows that with the increase of the modulation order, the influence of gain fluctuation and phase modulation error on the sensitivity becomes smaller, and the sensitivity of the uniform circular multiphase modulation correlation radiometer tends to the sensitivity of the ideal correlation radiometer. © 2023 Beijing University of Aeronautics and Astronautics (BUAA). All rights reserved.
引用
收藏
页码:1857 / 1863
页数:6
相关论文
共 16 条
  • [1] ORABI F T, MOORE R K., Microwave remote sensing and radiometry, pp. 115-119, (1988)
  • [2] TIURI M E., Radio telescope receivers, Radio Astronomy, 7, pp. 452-457, (1986)
  • [3] TIURI M E., Radio astronomy receivers, IEEE Transactions on Military Electronics, 8, 3, pp. 264-272, (1964)
  • [4] LI Y M, JIANG M, YU R, Et al., System design of microwave radiometer of HY-2A satellite, Strategic Study of CAE, 15, 7, pp. 39-43, (2013)
  • [5] CHANDRA R, ZHOW H Y, BALASINGHAM I, Et al., On the opportunities and challenges in microwave medical sensing and imaging, IEEE Transactions on Bio-Medical Engineering, 62, 7, pp. 1667-1682, (2015)
  • [6] NANZER J A., Microwave and millimeter-wave remote sensing for security applications, pp. 156-162, (2015)
  • [7] MIAO J G, ZHENG C, HU A Y, Et al., Real-time passive millimeter wave imaging technology, Journal of Microwaves, 29, 1, pp. 100-112, (2013)
  • [8] HERSMAN M S, POE G A., Sensitivity of the total power radiometer with periodic absolute calibration, IEEE Transactions on Microwave Theory and Techniques, 29, 1, pp. 32-40, (1981)
  • [9] FARIS J J., Sensitivity of a correlation radiometer, Journal of Research of the National Bureau of Standards, Section C:Engineering and Instrumentation, 71C, 2, (1967)
  • [10] GUI L Q, ZHANG Z Y, GUO W., Review of studies of microwave radiometer sensitivity improvements, Telemetry & Telecontrol, 25, 6, pp. 1-5, (2004)