Comparison of pull-out capacities of robotically and manually drilled and set fasteners

被引:0
|
作者
Ortner, Maximilian [1 ]
Schwenn, Michael [2 ]
Kromoser, Benjamin [1 ]
机构
[1] Univ Nat Resources & Life Sci, Inst Green Civil Engn, Peter Jordan Str 82, A-1190 Vienna, Austria
[2] Univ Nat Resources & Life Sci, Inst Struct Engn, Peter Jordan Str 82, A-1190 Vienna, Austria
关键词
Automation; Concrete; Construction; Drilling; Robotics; Fasteners; Automation in construction; TEST BENCH; TECHNOLOGIES; AUTOMATION; GEOMETRY;
D O I
10.1016/j.autcon.2024.105365
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The performance of post-installed fasteners in concrete can be affected by the chosen drilling and setting techniques. In the context of the development of a drilling robot for construction site implementation the impact of an automated setting process on the pull-out loads of fastening systems was evaluated. This article investigates the effect of two different fixing systems, drop-in expansion and chemical anchors, on the pull-out behaviour of manual and robotic drilling and installation. While for chemical anchors, the results indicate that robotic installation leads to similar pull-out forces with smaller deviation, expansion anchors in robotically drilled holes show slightly lower pull-out loads than those in manually drilled holes. Furthermore, a more uniform pull-out behaviour was observed for chemical anchors when set by the robot. In conclusion it can be shown that robotically set fasteners achieve a comparable performance, presenting a feasible automation approach for the construction industry.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] PULL-OUT CAPACITIES OF SOIL ANCHORS
    BRIASSOULIS, D
    CURTIS, JO
    TRANSACTIONS OF THE ASAE, 1984, 27 (01): : 153 - 158
  • [2] PULL-OUT CAPACITIES OF SOIL ANCHORS.
    Briassoulis, D.
    Curtis, J.O.
    Transactions of the American Society of Agricultural Engineers, 1984, 27 (01): : 153 - 158
  • [3] Tests of the resistance to pull-out fasteners from top sandwich panel
    Ignatowicz, Rajmund Leszek
    Gierczak, Jan
    JOURNAL OF BUILDING ENGINEERING, 2021, 35
  • [4] Installation and pull-out capacities of drag-in plate anchors
    Elkhatib, S
    Lonnie, B
    Randolph, MF
    PROCEEDINGS OF THE TWELFTH (2002) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 2, 2002, : 648 - 654
  • [5] COMPARISON OF MATERIALS FOR STAPLE PULL-OUT TESTS
    THOMAS, AMC
    PYNSENT, PB
    MCCOMBE, PF
    JOURNAL OF TESTING AND EVALUATION, 1992, 20 (03) : 233 - 236
  • [6] Numerical study of pull-out capacities of dynamically embedded plate anchors
    Wang, D.
    O'Loughlin, C. D.
    CANADIAN GEOTECHNICAL JOURNAL, 2014, 51 (11) : 1263 - 1272
  • [7] PULL-OUT OF STEEL FASTENERS FROM A LAMINATED COMPOSITE SUBJECTED TO EXTERNAL-PRESSURE
    PARRY, TV
    WILSON, JM
    LECK, DC
    COMPOSITES SCIENCE AND TECHNOLOGY, 1987, 28 (04) : 279 - 290
  • [8] Comparison of Crack Propagation Analyses in a Pull-Out Test
    Gontarz, Jakub
    Podgorski, Jerzy
    Siegmund, Michal
    COMPUTER METHODS IN MECHANICS (CMM2017), 2018, 1922
  • [9] Pull-out load capacity of thin composite dowels as fasteners for reinforced concrete wall panels
    Penkert, Fabian
    Pahn, Matthias
    BETON- UND STAHLBETONBAU, 2022, 117 (08) : 600 - 612
  • [10] Pull-out capacities of screw connections in thin steel battens exposed to bushfire conditions
    Athmarajah, Gopikrishna
    Mahendran, Mahen
    Ariyanayagam, Anthony
    THIN-WALLED STRUCTURES, 2024, 197