An analytical method for laterally loaded large-diameter steel pipe piles based on load-transfer curves

被引:0
|
作者
Zhai E. [1 ,2 ]
Shi S. [1 ]
Hu Z. [3 ]
Xu C. [1 ]
机构
[1] Key Laboratory of Urban Security and Disaster Engineering, Beijing University of Technology, Beijing
[2] Goldwind Science and Technology Co., Ltd., Beijing
[3] China Three Gorges Corporation Co., Ltd., Beijing
基金
中国国家自然科学基金;
关键词
Finite element method; Large-diameter steel pipe piles; Load-transfer curves; Offshore windpower; P-y method; Pile foundation; Soil-added-resistance force;
D O I
10.13722/j.cnki.jrme.2018.0943
中图分类号
学科分类号
摘要
Offshore turbines are often supported on large-diameter steel pipe monopoles. There is a significant effect of soil-added-resistance force caused by the rotation of the pile section of laterally loaded large-diameter steel pipe piles. The impact of the soil-added-resistance force on pile lateral capacity should be taken into account. A modified Winkler foundation beam model was proposed to model the lateral bearing loads of large-diameter steel pipe piles, in which the soil and the pile are respectively modeled by nonlinear springs and C1 beam elements considering the shear deformation. Assuming that the secant stiffness of the soil load transfer curves inside a pile element is linear, finite element formulas were deduced to develop a coupling method which can take into account the soil-added-resistance force caused by the rotation of the pile section, and a corresponding program was written. Two case studies were performed to verify the coupling method developed in this paper, and their computed results were compared with those obtained by the p-y method only considering the lateral nonlinear springs' effect. The results show that the coupling method can better predict the laterally loaded characteristics of the large-diameter steel pipe pile. The closer the deformation of the large-diameter steel monopile is to the rigid rotation, the more obvious the soil-added-resistance force caused by the rotation of the pile section. On the contrary, the soil-added-resistance force can be ignored while the deformation of the large-diameter steel pipe pile is close to the flexible deformation. © 2019, Science Press. All right reserved.
引用
收藏
页码:365 / 375
页数:10
相关论文
共 29 条
  • [1] Zhang J., Fowai I., Sun K., A glance at offshore wind turbine foundation structures, Brodogradnja, 67, 2, pp. 101-113, (2016)
  • [2] Selvadural A.P.S., Elastic Analysis of Soil-Foundation Interaction, (1981)
  • [3] Mcclelland B., Focht J.A., Soil modulus for laterally loaded piles, Transactions of the American Society of Civil Engineers, 123, 1, pp. 1049-1063, (1958)
  • [4] Reese L.C., Cox W.R., Koop F.D., Analysis of laterally loaded piles in sand, Proceedings of 6th Annual Offshore Technology Conference, pp. 473-483, (1974)
  • [5] O'Neil M.W., Murchison J.M., An Evaluation of p-y Relationships in Sand, (1983)
  • [6] Murchison J.M., O'Neill M.W., Evaluation of py relationships in cohesionless soils, Analysis and Design of Pile Foundations, pp. 174-191, (1984)
  • [7] Georgiadis M., Anagnostopoulos C., Saflekou S., Centrifugal testing of laterally loaded piles in sand, Canadian Geotechnical Journal, 29, 2, pp. 208-216, (1992)
  • [8] Wang G., Yang M., Nonlinear analysis of laterally loaded piles in sand, Rock and Soil Mechanics, 32, pp. 261-267, (2011)
  • [9] Matlock H., Correlation for design of laterally loaded piles in soft clay, Offshore Technology in Civil Engineering, pp. 77-94, (1970)
  • [10] Reese L.C., Welch R.C., Lateral loading of deep foundations in stiff clay, Journal of Geotechnical and Geoenvironmental Engineering, 101, 7, pp. 633-649, (1975)