摘要
Introduction: The medical use of ionizing radiation contributes the largest amount of man-made radiation exposure and ranks second to natural background radiation. Adhering to the standard radiation protection measures minimizes radiation dose to patients, staff, and other public members. Aim: This study aimed to evaluate radiation protection measures in radiological facilities in the Kano metropolis, Nigeria. Materials and Methods: This was a cross-sectional study conducted in the Kano metropolis, Nigeria, between February 2021 and May 2021. A structured questionnaire was formulated. The measuring tool was validated by expert and experienced colleagues. The reliability of the measuring tool was tested using a pilot study, and Cronbach's alpha reliability coefficient was found to be 0.815. A total of 101 respondents were recruited. These were the radiographers working in the functional radiological facilities. The obtained data were analyzed using SPSS software version 23.0, and P <0.05 was considered statistically significant. Results: X-ray room design was sufficient in the majority of radiological facilities 67 (66.7%). Insufficient availability of personnel protective devices in 47 (46.9%) respondents was observed. The majority, 24 (23.9%) of the respondents, indicated poor utilization of personnel protective devices. There was insufficient registration and records of radiation safety measures 26 (26.0%). Only 48 (47.5%) respondents indicated the availability of a QA committee in their facility. Fifty-two (51.5%) of the respondents reported that they have medical physicists/engineers available to provide support within their department, while only 25 (25.7%) had radiation safety officers in their facilities. There was a weak negative correlation between lead aprons and lead rubber gloves with the level of staff training, respectively (r = -0.254, P = 0.010; r = -0.214, P = 0.031). Conclusion: There was sufficient X-ray room design in the Kano metropolis. An insufficient availability of personal protective devices, poor utilization, registration, and records of radiation safety measures was observed. There were inadequate QA committee and QC test in the majority of the radiological facilities. A weak negative correlation was observed between the use of lead aprons and lead rubber gloves with the level of staff training.
引用
收藏
页码:118 / 124
页数:7
相关论文
共 50 条
  • [1] Air Pollution and Environmental Implications in Kano Metropolis Nigeria
    Abdullahi, Hashim
    Sinniah, Gobi Krishna
    Siong, Ho Chin
    Wei, Li Rui
    2ND INTERNATIONAL CONFERENCE ON AIR POLLUTION AND ENVIRONMENTAL ENGINEERING, 2020, 450
  • [2] Assessment of tannery industrial effluents from kano metropolis, kano state, Nigeria
    Department of Chemistry, University of Maiduguri, Faculty of Science, P.M.B. 1069, Maiduguri Borno State, Nigeria
    J. Appl. Sci., 2007, 19 (2788-2793):
  • [3] The current status of ultrasound practice in Kano metropolis, Nigeria
    Sidi, Mohammed
    Sani, Ghali Makoda
    Ya'u, Anas
    Zira, Joseph Dlama
    Loshugno, Shem Samuel
    Luntsi, Geofrey
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):
  • [4] The current status of ultrasound practice in Kano metropolis, Nigeria
    Mohammed Sidi
    Ghali Makoda Sani
    Anas Ya’u
    Joseph Dlama Zira
    Shem Samuel Loshugno
    Geofrey Luntsi
    Egyptian Journal of Radiology and Nuclear Medicine, 52
  • [5] Assessing gaseous pollutants and air quality in some areas of Kano metropolis, Kano, Nigeria
    Garba, M. D.
    Yunusa, M. S.
    ENVIRONMENTAL IMPACT III, 2016, 203 : 125 - 134
  • [6] Public health implications of sewage ponds in Kano metropolis, Nigeria
    Mukhtar, M. D.
    Indabawa, I. I.
    Imam, T. S.
    JOURNAL OF FOOD AGRICULTURE & ENVIRONMENT, 2010, 8 (02): : 25 - 31
  • [7] Occupational exposure to metals among blacksmiths in Kano Metropolis, Nigeria
    Abdullahi, Ibrahim Lawal
    Sani, Ali
    Jibril, Bilkisu Aminu
    ENVIRONMENTAL HEALTH ENGINEERING AND MANAGEMENT JOURNAL, 2020, 7 (02): : 135 - 141
  • [8] A Strategy For Sustainable Mananagement Of Municipal Solid Waste In Kano Metropolis, Nigeria
    Nabegu, Aliyu Baba
    ENVIRONMENTAL ENGINEERING, PTS 1-4, 2014, 864-867 : 1968 - 1975
  • [9] In search of missing links: urbanisation and climate change in Kano Metropolis, Nigeria
    Mohammed, Murtala Uba
    Hassan, Nura Ibrahim
    Badamasi, Murtala Muhammad
    INTERNATIONAL JOURNAL OF URBAN SUSTAINABLE DEVELOPMENT, 2019, 11 (03) : 309 - 318
  • [10] Impact of smoking on nasal mucociliary clearance time in Kano metropolis, Nigeria
    Mahmud, Ahmad
    Salisu, Abubakar
    Kolo, Emmanuel
    Hasheem, Muhammad
    Bello-Muhammad, Nafisatu
    Tukur, Ahmad
    Nuhu, Yasir
    Jalo, Rabiu
    WORLD JOURNAL OF OTORHINOLARYNGOLOGY-HEAD & NECK SURGERY, 2023, 9 (01): : 53 - 58