Evaluation of the effect of self-assembling peptide and fluoride varnish, alone or in combination with laser irradiation, on artificial enamel caries: a SEM/EDS and Micro-CT study

被引:1
|
作者
Asik, Asli [1 ]
Oncag, Oezant [2 ]
机构
[1] Izmir Tinaztepe Univ, Fac Dent, Dept Pediat Dent, Izmir, Turkiye
[2] Ege Univ, Fac Dent, Dept Pediat Dent, Erzene Mah Ankara Cad 172-109, Izmir, Turkiye
关键词
Self-assembling peptide P11-4; Enamel biomineralization; Dental laser; Micro-computed tomography; Scanning electron microscopy; Energy dispersive x-ray spectroscopy; ACID RESISTANCE; DENTAL ENAMEL; IN-VITRO; BIOMIMETIC REMINERALIZATION; ERYAG LASER; LESIONS; INHIBITION; P-11-4;
D O I
10.1007/s00784-024-05901-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective The aim of this study was to investigate the effect of remineralization agents such as fluoride varnish and P-11-4, alone and in combination with Er: YAG laser, on in-vitro hard tissue repair in artificial enamel lesions. Materials and methods A total of sixty enamel surfaces of 4 x 5 mm in size were created on both the buccal and lingual sides of thirty extracted wisdom teeth. Remineralization agents were applied to the specimens that were grouped as follows: Group 1, control; Group 2, fluoride varnish (FV); Group 3, P-11-4; Group 4, laser; Group 5, laser + FV; and Group 6, laser + P-11-4. The fluorescence level was determined with DiagnoDent. The enamel mineral density, area and volume, and caries lesion area and volume were determined with micro-computed tomography (mu CT), surface features were evaluated using scanning electron microscopy (SEM), and elemental analysis was performed using energy dispersive x-ray spectroscopy (EDS) . Results For specimens treated only with self-assembling peptide P-11-4, the caries lesion area (mm(2)) values were 38.19 and 21.62, and the caries lesion volume (mm(3)) values were 6.27 and 2.99, respectively for pre- and post-treatment. In combination usage of self-assembling peptide P-11-4 and laser, the caries lesion area (mm(2)) values were 38.39 and 16.91, and the caries lesion volume (mm(3)) values were 11.15 and 3.64, respectively for pre- and post-treatment. In the application of the P-11-4 alone and in combination with laser, there was a statistically significant decrease in DiagnoDent values, an increase in enamel volume(mm(3)),enamel area(mm(2)) and mineral density(g/cm(3)) values and a decrease in caries lesion volume(mm(3)) and area(mm(2)) obtained by mu CT, and an increase in %Ca and %F values obtained by SEM/EDS analysis (p < 0.05). It was discovered that the samples treated with P-11-4 had a considerably higher rise in the Ca/P ratio than the samples treated with FV (p < 0.05). The calcium content increased significantly more when P-11-4 application was combined with laser irradiation (p < 0.05). Conclusions The combined use of self-assembling peptide P-11-4 and laser accelerated the remineralization process and increased the remineralization capacity.
引用
收藏
页数:11
相关论文
共 6 条
  • [1] Combined Effect of a Bioinspired Self-Assembling Peptide and Fluoride Varnish on Remineralisation of Artificial Early Enamel Caries Lesion: An in vitro Study
    Chen, Kerry
    Li, Kai Chun
    Ekambaram, Manikandan
    Zhang, Ya
    Fu, Yipeng
    Mei, May Lei
    CARIES RESEARCH, 2024, 58 (03) : 173 - 183
  • [2] Comparative evaluation of fluoride varnishes, self-assembling peptide-based remineralization agent, and enamel matrix protein derivative on artificial enamel remineralization in vitro
    Lena Sezici, Yagmur
    Yetkiner, Enver
    Aykut Yetkiner, Arzu
    Eden, Ece
    Attin, Rengin
    PROGRESS IN ORTHODONTICS, 2021, 22 (01)
  • [3] Comparative evaluation of fluoride varnishes, self-assembling peptide-based remineralization agent, and enamel matrix protein derivative on artificial enamel remineralization in vitro
    Yağmur Lena Sezici
    Enver Yetkiner
    Arzu Aykut Yetkiner
    Ece Eden
    Rengin Attin
    Progress in Orthodontics, 22
  • [4] Comparative analysis of the effect of self-assembling peptide P11-4 on enamel erosion: a confocal laser scanning microscopy study
    Yilmaz Sen, Buse
    Akcay, Merve
    CLINICAL ORAL INVESTIGATIONS, 2024, 29 (01)
  • [5] Comparative Evaluation between Self-Assembling Peptide P11-4 and ACP CPP in Enamel Remineralization Post Er:YAG Laser Irradiation - A Confocal Laser Scanning Microscopic Study
    Bhargavi, H.
    Naik, Savitha B.
    Kumar, N. Kiran
    Merwade, Seema
    Brigit, Biji
    Bhumralkar, Shriya Sunil
    Kadam, Ashwini Suresh
    Preetham, H. S.
    CONTEMPORARY CLINICAL DENTISTRY, 2025, 16 (01) : 3 - 9
  • [6] Effect of Erbium, Chromium-doped: Yttrium, Scandium, Gallium and Garnet Laser Tooth Preparation on Gap Formation of Universal Adhesive Bonded to Enamel and Dentin: A Micro-CT and SEM Study
    AlQussier, Anfal
    Awliya, Wedad
    JOURNAL OF LASERS IN MEDICAL SCIENCES, 2022, 13