Quality of different obturation techniques to fill perforating internal root resorption: a micro-computed tomographic study

被引:0
|
作者
Sadat, Shaimaa Mohamed Abu El [1 ]
Chew, Hooi Pin [2 ,3 ]
Fok, Alex [2 ]
Elashiry, Mohamed Mohamed [4 ,5 ]
Elshenawy, Ahmed M. [6 ,7 ]
Saber, Shehabeldin [7 ,8 ]
机构
[1] Ain Shams Univ, Fac Dent, Dept Oral & Maxillofacial Radiol, Cairo, Egypt
[2] Univ Minnesota, Minnesota Dent Res Ctr Biomat & Biomech, Minneapolis, MN USA
[3] Univ Minnesota, Div Operat Dent, Minneapolis, MN USA
[4] Augusta Univ, Dent Coll Georgia, Dept Endodont, Augusta, GA USA
[5] Ain Shams Univ, Fac Dent, Dept Endodont, Cairo, Egypt
[6] British Univ Egypt, Fac Dent, Dept Orthodont, Cairo, Egypt
[7] British Univ Egypt, Fac Dent, Hlth Res Ctr Excellence, Dent Sci Res Grp, Cairo, Egypt
[8] British Univ Egypt, Fac Dent, Dept Endodont, 81-11-11 El Rehab, Cairo 11841, Egypt
来源
BMC ORAL HEALTH | 2024年 / 24卷 / 01期
关键词
Internal Root Resorption; Root canal perforation; Root canal Obturation; GuttaFlow-2; NeoSealer Flo; Micro-CT; GUTTA-PERCHA; ABILITY; TEETH;
D O I
10.1186/s12903-024-04518-w
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundThis study aimed to assess the quality of various obturation techniques to fill perforation caused by internal root resorption using Micro-computed Tomography.MethodsCone-beam computed tomography images of a maxillary central incisor tooth with perforating internal resorptive defect were used to create a 3D printed model of the affected tooth. The replicas were divided into four groups based on the obturation technique used. The techniques included Group 1: a polydimethylsiloxane-based sealer (GuttaFlow-2) with gutta-percha. Group 2: same as Group 1 except for using a pre-mixed Bioceramic-based sealer (NeoSEALER Flo). Group 3: the defect was filled entirely using the NeoSealer Flo Bioceramic-based sealer. Group 4: the samples were obturated using the warm vertical compaction technique with a resin-based sealer (ADSeal). The resin models were then scanned a micro-computed scanner to evaluate the percentage of voids in each group.ResultsThe results showed that NeoSEALER Flo groups had significantly the highest volume of voids while GuttaFlow-2 and warm vertical compaction groups had the lowest void volume.ConclusionsGuttaFlow-2 and warm vertical compaction techniques performed best in filling the internal resorptive defect.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Obturation quality of calcium silicate-based cements placed with different techniques in teeth with perforating internal root resorption: a micro-computed tomographic study
    Eren, Selen Kucukkaya
    Aksel, Hacer
    Ors, Sevinc Askerbeyli
    Serper, Ahmet
    Kocak, Yaprak
    Ocak, Mert
    Celik, Hakan Hamdi
    [J]. CLINICAL ORAL INVESTIGATIONS, 2019, 23 (02) : 805 - 811
  • [2] Obturation quality of calcium silicate-based cements placed with different techniques in teeth with perforating internal root resorption: a micro-computed tomographic study
    Selen Küçükkaya Eren
    Hacer Aksel
    Sevinc Askerbeyli Örs
    Ahmet Serper
    Yaprak Koçak
    Mert Ocak
    Hakan Hamdi Çelik
    [J]. Clinical Oral Investigations, 2019, 23 : 805 - 811
  • [3] Effect of Post Space Preparation on Apical Obturation Quality of Teeth Obturated with Different Techniques: A Micro-computed Tomographic Study
    Eren, Selen Kucukkaya
    Ors, Sevinc Askerbeyli
    Yilmaz, Zeliha
    [J]. JOURNAL OF ENDODONTICS, 2017, 43 (07) : 1152 - 1156
  • [4] Evaluation of Root Canal Obturation Quality in Deciduous Molars with Different Obturation Materials: An In Vitro Micro-Computed Tomography Study
    Orhan, Ayse, I
    Tatli, Esra C.
    [J]. BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [5] Micro-computed Tomographic Evaluation of the Quality of Root Canal Fillings in Mandibular Molars after Obturation for 54 Months
    Liu, He
    Lai, Wendy Wing Man
    Hieawy, Ahmed
    Gao, Yuan
    von Bergmann, HsingChi
    Haapasalo, Markus
    Tay, Franklin R.
    Shen, Ya
    [J]. JOURNAL OF ENDODONTICS, 2021, 47 (11) : 1783 - 1789
  • [6] Evaluation of Different Techniques and Materials for Filling in 3-dimensional Printed Teeth Replicas with Perforating Internal Resorption by Means of Micro-Computed Tomography
    Torres-Carrilo, Angelo J. S.
    Assis, Helena C.
    Salazar-Gamarra, Rodrigo E.
    Teodosio, Leonardo Moreira
    Silva-Sousa, Alice C.
    Mazzi-Chaves, Jardel F.
    Ferreira-Soares, Priscila B.
    Sousa-Neto, Manoel D.
    Lopes-Olhe, Fabiane C.
    [J]. JOURNAL OF ENDODONTICS, 2024, 50 (02) : 205 - 212
  • [7] A micro-computed tomographic analysis of obturation quality and retreatability of an epoxy resin-based sealer
    Abiad, Roula S.
    Neelakantan, Prasanna
    Buscema, Ivan
    Ali, Islam A.
    Conte, Gianluca
    La Rosa, Giusy R. M.
    Generali, Luigi
    Cicciu, Marco
    Pedulla, Eugenio
    [J]. MINERVA DENTAL AND ORAL SCIENCE, 2022, 71 (03) : 131 - 138
  • [8] Micro-computed tomographic assessment of quality of obturation in the apical third with continuous wave vertical compaction and single match taper sized cone obturation techniques
    Alshehri, Mohammed
    Alamri, Hadi M.
    Alshwaimi, Emad
    Kujan, Omar
    [J]. SCANNING, 2016, 38 (04) : 352 - 356
  • [9] The isthmuses of the mesial root of mandibular molars: a micro-computed tomographic study
    Mannocci, F
    Peru, M
    Sherriff, M
    Cook, R
    Ford, TRP
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (08) : 558 - 563
  • [10] Micro-computed tomographic evaluation of single-cone obturation with three sealers
    Zare, Sahar
    Shen, Ivy
    Zhu, Qiang
    Ahn, Chul
    Primus, Carolyn
    Komabayashi, Takashi
    [J]. RESTORATIVE DENTISTRY AND ENDODONTICS, 2021, 46 (02):