An Imaging-Compatible Oral Retractor System for Transoral Robotic Surgery

被引:0
|
作者
Shi, Yuan [1 ]
Wu, Xiaotian [1 ]
Paydarfar, Joseph A. [1 ,2 ,3 ]
Halter, Ryan J. [1 ,3 ]
机构
[1] Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA
[2] Dartmouth Hitchcock Med Ctr, Dept Surg, Sect Otolaryngol Audiol & Maxillofacial Surg, Lebanon, NH USA
[3] Dartmouth Coll, Geisel Sch Med, Hanover, NH USA
关键词
Oral retractor; Transoral robotic surgery; Intraoperative imaging; Image guidance; da Vinci surgical systems; 3D printing; OUTCOMES;
D O I
10.1007/s10439-024-03536-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aimed to develop and validate a Computed Tomography (CT)/Magnetic Resonance Imaging (MRI)-compatible polymer oral retractor system to enable intraoperative image guidance for transoral robotic surgery (TORS). The retractor was designed based on standard-of-care metallic retractors and 3D (three-dimensional) printed with carbon fiber composite and nylon. The system was comprehensively evaluated in bench-top and cadaveric experiments in terms of its ability to enable intraoperative CT/MR images during TORS, functionality including surgical exposure and working volume, usability, compatibility with da Vinci surgical systems, feasibility for disinfection or sterilization, and robustness over an extended period of time. The polymer retractor system enabled the acquisition of high-resolution and artifact-free intraoperative CT/MR images during TORS. With an inter-incisive distance of 42.55 mm and a working volume of 200.09 cm(3), it provided surgical exposure comparable to standard-of-care metallic retractors. The system proved intuitive and compatible with da Vinci S, Xi, and Single Port systems, enabling successful mock surgical tasks performed by surgeons and residents. The retractor components could be effectively disinfected or sterilized for clinical use without significant compromise in material strength, with STERRAD considered the optimal method. Throughout a 2 h mock procedure, the retractor system showed minimal displacements (<1.5 mm) due to surrounding tissue deformation, with insignificant device deformation. The 3D-printed polymer retractor system successfully enabled artifact-free intraoperative CT/MR imaging in TORS for the first time and demonstrated feasibility for clinical use. This breakthrough opens the door to surgical navigation with intraoperative image guidance in TORS, offering the potential to significantly improve surgical outcomes and patients' quality of life.
引用
收藏
页码:2473 / 2484
页数:12
相关论文
共 50 条
  • [1] Imaging-compatible oral retractor system for use in image-guided transoral robotic surgery
    Shi, Yuan
    Wu, Xiaotian
    Paydarfar, Joseph A.
    Halter, Ryan J.
    [J]. MEDICAL IMAGING 2021: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11598
  • [2] Laryngeal Advanced Retractor System: A New Retractor for Transoral Robotic Surgery
    Remacle, Marc
    Matar, Nayla
    Lawson, Georges
    Bachy, Vincent
    [J]. OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2011, 145 (04) : 694 - 696
  • [3] Stormram 3 A Magnetic Resonance Imaging-Compatible Robotic System for Breast Biopsy
    Groenhuis, Vincent
    Veltman, Jeroen
    Siepel, Francoise J.
    Stramigioli, Stefano
    [J]. IEEE ROBOTICS & AUTOMATION MAGAZINE, 2017, 24 (02) : 34 - 41
  • [4] First use of a new retractor in transoral robotic surgery (TORS)
    Hasskamp, P.
    Lang, S.
    Holtmann, L.
    Stuck, B. A.
    Mattheis, S.
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (07) : 1913 - 1917
  • [5] First use of a new retractor in transoral robotic surgery (TORS)
    P. Hasskamp
    S. Lang
    L. Holtmann
    B. A. Stuck
    S. Mattheis
    [J]. European Archives of Oto-Rhino-Laryngology, 2016, 273 : 1913 - 1917
  • [6] Preoperative predictors of difficult hypopharyngeal exposure by retractor for transoral robotic surgery
    Fujiwara, Kazunori
    Koyama, Satoshi
    Donishi, Ryouhei
    Fukuhara, Takahiro
    Miyake, Naritomo
    Takeuchi, Hiromi
    [J]. INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2019, 24 (01) : 53 - 59
  • [7] Preoperative predictors of difficult hypopharyngeal exposure by retractor for transoral robotic surgery
    Kazunori Fujiwara
    Satoshi Koyama
    Ryouhei Donishi
    Takahiro Fukuhara
    Naritomo Miyake
    Hiromi Takeuchi
    [J]. International Journal of Clinical Oncology, 2019, 24 : 53 - 59
  • [8] Effect of Magnetic Resonance Imaging on the Motion Accuracy of Magnetic Resonance Imaging-compatible Focused Ultrasound Robotic System
    Antoniou, Anastasia
    Evripidou, Nikolas
    Chrysanthou, Antreas
    Georgiou, Leonidas
    Ioannides, Cleanthis
    Spanoudes, Kyriakos
    Damianou, Christakis
    [J]. JOURNAL OF MEDICAL PHYSICS, 2024, 49 (02) : 203 - 212
  • [9] Use of the self-retaining Alexis ring retractor in transoral robotic surgery
    Perenyei, Miklos
    Dobbs, Thomas D.
    Fraser, Lisa R.
    Winter, Stuart C.
    [J]. HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2017, 39 (10): : 2132 - 2134
  • [10] MR Imaging-Compatible Electrode System for an Electroencephalography Epilepsy Monitoring Unit
    Mirsattari, S. M.
    Tapsell, L. M.
    Ives, J. R.
    Lee, D. H.