Optimizing the use-by date of reusable medical devices. Experience in a healthcare establishment

被引:0
|
作者
Vidor, Manon [1 ]
Raguenes, Christelle [1 ]
Astier, Helene [1 ]
Gbaguidi, Gilles [1 ]
Le Tohic, Sarah [1 ]
机构
[1] Hop Instruct Armees Laveran, Serv Pharm Hosp, 34 Blvd Laveran, F-13013 Marseille, France
来源
ANNALES PHARMACEUTIQUES FRANCAISES | 2024年 / 82卷 / 02期
关键词
Medical device; Hazard analysis and critical control point; Process evaluation;
D O I
10.1016/j.pharma.2023.12.007
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objectives. - Sterilized reusable medical devices have a use -by date, after which sterility is no longer guaranteed. There is currently no consensus on how this should be determined. The aim is to re-evaluate the expiry date of reusable medical devices, by means of a risk analysis and an assessment of the maintenance of the sterile state of reusable medical devices over time. Methods. - The risk analysis focused on the stages whose malfunction could compromise the sterility of reusable medical devices over time: packaging, transport and storage. Risk mapping was carried out in accordance with the methodology recommended by the French Health Authority. Based on standard NF EN ISO 11737, the assessment of the maintenance of the sterile state was checked on reusable medical devices after two, four and six months storage and on reusable medical devices that had expired more than a year previously. Results. - The risk analysis identified four failures and sixty-eight potential causes. The most sensitive stage was storage, which accounted for most of the critical and major causes. Improvement actions were proposed, such as the definition of a container maintenance plan. At the same time, 256 reusable medical devices were tested. The cultures remained sterile for all the containers, for folded products tested at 6 months and more and for the sachets tested at 2 and 4 months and at more than one year of storage. Conclusions. - The DLU has been extended to 4 months for sachets, 6 months for folded products and maintained at six months for containers. (c) 2023 Academie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:292 / 305
页数:14
相关论文
共 26 条
  • [1] Guideline for the establishment of use-by date and best-before date in foods
    Maitani, T
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2005, 46 (03): : J198 - J202
  • [2] REPROCESSING OF SINGLE USE MEDICAL DEVICES. INITIAL EXPERIENCE
    Melo, J.
    Ferreira, A.
    BRITISH JOURNAL OF SURGERY, 2016, 103 : 7 - 7
  • [3] Effectiveness of autoclaving in sterilizing reusable medical devices in healthcare facilities
    Panta, Gopal
    Richardson, Ann K.
    Shaw, Ian C.
    JOURNAL OF INFECTION IN DEVELOPING COUNTRIES, 2019, 13 (10): : 858 - 864
  • [4] Optimizing Fail-Safe Use of Complex Medical Devices
    Hercules, Patricia
    Shabot, M. Michael
    Ryan, Teresa
    Ratcliff, Susan
    AACN ADVANCED CRITICAL CARE, 2019, 30 (01) : 25 - 39
  • [5] Medical Management of Patients with the HeartMate II Left Ventricular Assist Devices. A Single Center Experience
    Burdorf, Adam E.
    Um, John
    Raichlin, Eugenia
    Rome, Eric
    Darrah, Jason
    Varnado, Sara
    Lowes, Brian
    JOURNAL OF CARDIAC FAILURE, 2015, 21 (08) : S122 - S123
  • [6] Off-Label Use of Drugs and Devices: Role of Medical Professionals in the Establishment of Parameters for Their Use
    Long, Donlin
    Watts, Clark
    NEUROSURGERY, 2013, 72 (06) : 1014 - 1020
  • [7] Improper handling of reusable medical devices post-use in inpatient units: Implications for reprocessing
    Veiga Tipple, Anaclara Ferreira
    de Freitas, Lucimara Rodrigues
    Umbelina Spagnoli, Jeenna Louhanna
    Cunha Neves, Heliny Carneiro
    Melo, Dulcelene de Sousa
    Costa, Dayane de Melo
    INFECTION DISEASE & HEALTH, 2021, 26 (01) : 81 - 83
  • [8] THE USE OF MERCURY-BASED MEDICAL DEVICES ACROSS CROATIAN HEALTHCARE FACILITIES
    Holcer, Natasa Janev
    Maricevic, Marija
    Miocic-Juran, Anamarija
    ARHIV ZA HIGIJENU RADA I TOKSIKOLOGIJU-ARCHIVES OF INDUSTRIAL HYGIENE AND TOXICOLOGY, 2012, 63 (01): : 41 - 47
  • [10] An evaluation of the feasibility of an implantable biological galvanic cell for use as a power source for electrically operated implantable medical devices.
    Abbey, KR
    JOURNAL OF INVESTIGATIVE MEDICINE, 1999, 47 (02) : 14A - 14A