Research on Electromagnetic Interference of AC Transmission Line to Adjacent Buried Pipeline Under Transient States

被引:0
|
作者
Huang W. [1 ]
Zhou S. [2 ]
Sun C. [1 ]
Mo B. [2 ]
Han M. [2 ]
Kang J. [2 ]
Luo Y. [1 ]
Wu S. [1 ]
Jing H. [2 ]
机构
[1] School of Electrical Engineering, Xi'an Jiaotong University, Xi'an
[2] Electric Power Research Institute, State Grid Qinghai Electric Power Company, Xining
关键词
AC transmission line; Buried pipeline; Electromagnetic interference; Grounding fault; Lightning; Pipeline-to-soil potential; Protection;
D O I
10.13334/j.0258-8013.pcsee.200924
中图分类号
学科分类号
摘要
The transient impact of AC transmission line on pipeline is summarized, which is divided into line switching and fault states, while the latter, depending on the circuit structure, includes line grounding and breaking, lightning strike on the tower without back flashover and back flashover. The transient inductive and conductive coupling between power line and adjacent oil/gas pipeline were analyzed in this paper. The corresponding equivalent circuits of these transient states were established. The electromagnetic interference of Haixi-Tala 750 kV AC transmission line on the adjacent buried natural gas pipeline of the Wulan section was studied. The induced voltage of the pipeline is relative lower during power line switching. The maximum pipeline-to-soil potentials are 4.3kV and 12.9kV respectively during single-phase grounding and line break fault, and the peak voltages reaches 18.4kV and 37.2kV respectively with a lightning strike on the tower and back flashover. The inductive interference from fault phase current partially counteracts the conductive coupling of the grounding current when back flashover occurs. Solid state decouplers are taken as the protection of the pipeline, then the electromagnetic interference is reduced and its propagation is suppressed. The results can provide technical support and reference for the design of common corridor of transmission lines and buried pipelines. © 2021 Chin. Soc. for Elec. Eng.
引用
收藏
页码:275 / 285
页数:10
相关论文
共 31 条
  • [1] DAN D M, GEORGIS C C, LEVENTE C., AC interference on pipelines due to double circuit power lines: a detail study, Electric Power Systems Research, 103, pp. 1-8, (2013)
  • [2] LI Yexu, AC interference: an important problem faced by utilities in public corridors with power lines, (2005)
  • [3] GEORGIS C C, DIMITRIS P L, PETROS S D., A hybrid method for calculating the inductive interference caused by faulted power lines to nearby buried pipelines, IEEE Transactions on Power Delivery, 2, pp. 1465-1472, (2005)
  • [4] BONDS R W., The effect of overhead ac power lines paralleling ductile iron pipelines, (1999)
  • [5] KOUTEYNIKOFF P., Results of an international survey of the rules limiting interference coupled into metallic pipelines by high voltage power systems, Electra, 110, pp. 55-66, (1987)
  • [6] KOPSIDAS K, COTTON I., Induced voltages on long aerial and buried pipelines due to transmission line transients, IEEE Transactions on Power Delivery, 23, 3, pp. 1535-1543, (2008)
  • [7] CHRISTOFORIDIS G C, LABRIDIS D P., A hybrid method for calculating the inductive interference caused by faulted power lines to nearby buried pipelines, IEEE Transactions on Power Delivery, 20, 2, pp. 1465-1473, (2005)
  • [8] COTTON I, KOPSIDAS K, ZHANG Y., Comparison of transient and power frequency-induced voltages on a pipeline parallel to an overhead transmission line, IEEE Transactions on Power Delivery, 22, 3, pp. 1706-1714, (2007)
  • [9] LICHTENSTEIN J., AC and lightning hazards on pipe lines, Materials Perform, 31, 12, pp. 19-21, (1992)
  • [10] SOUTHEY R D, RUAN W, DAWALIBI F P, Et al., Estimating AC mitigation requirements for pipelines installed in high voltage ac corridors: Fault conditions, NACE International Conference Corrosion, pp. 1-12, (2003)