Influence of Forearm Postures on Hand-Wrist Gesture Recognition With Forearm Deformation Measurements
被引:0
|
作者:
论文数: 引用数:
h-index:
机构:
Cho, Sung-Gwi
[1
]
Zaffir, Muhammad Akmal Bin Mohammed
论文数: 0引用数: 0
h-index: 0
机构:
Nara Inst Sci & Technol, Grad Sch Sci & Technol, Div Informat Sci, Ikoma, Nara 6300192, JapanTokyo Denki Univ, Sch Sci & Engn, Div Elect Engn, Saitama 3500394, Japan
Zaffir, Muhammad Akmal Bin Mohammed
[2
]
Yoshikawa, Masahiro
论文数: 0引用数: 0
h-index: 0
机构:
Osaka Inst Technol, Grad Sch Robot & Design, Osaka 5308568, JapanTokyo Denki Univ, Sch Sci & Engn, Div Elect Engn, Saitama 3500394, Japan
Yoshikawa, Masahiro
[3
]
Takamatsu, Jun
论文数: 0引用数: 0
h-index: 0
机构:
Microsoft Corp, Appl Robot Res, Redmond, WA 98052 USATokyo Denki Univ, Sch Sci & Engn, Div Elect Engn, Saitama 3500394, Japan
Takamatsu, Jun
[4
]
论文数: 引用数:
h-index:
机构:
Wada, Takahiro
[2
]
机构:
[1] Tokyo Denki Univ, Sch Sci & Engn, Div Elect Engn, Saitama 3500394, Japan
[2] Nara Inst Sci & Technol, Grad Sch Sci & Technol, Div Informat Sci, Ikoma, Nara 6300192, Japan
[3] Osaka Inst Technol, Grad Sch Robot & Design, Osaka 5308568, Japan
[4] Microsoft Corp, Appl Robot Res, Redmond, WA 98052 USA
来源:
IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS
|
2024年
/
6卷
/
02期
关键词:
Hand-wrist gesture recognition;
forearm deformation;
forearm postures;
distance sensor array;
support vector machine;
FORCE MYOGRAPHY;
ELECTROMYOGRAPHY;
PRONATION;
ELBOW;
MMG;
D O I:
10.1109/TMRB.2024.3377364
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
In hand-wrist gesture recognition based on biosignal, the negative influence of forearm posture variation on recognition accuracy is a common problem. Although the elbow/forearm-rotation angle influence has been investigated in several previous studies, the combined influence of these angles is still unclear. Therefore, we investigated the influence of forearm postures (both elbow and forearm rotation angles) by comparing the accuracies under various data configurations in which the posture combinations used for training the recognition model were different. We collected forearm deformation as biosignal for seven hand-wrist gestures under nine different forearm postures (combinations of three elbow and forearm rotation angles). The accuracy comparison results showed that the forearm rotation angle strongly affected recognition compared with the elbow angle, and the complex combination of elbow and forearm rotation angles had a stronger influence. The results of this study suggest that data collection can be made efficient by considering variations in the forearm postures. If time is available for data collection, it is effective to focus on the interpolation of forearm deformation to the untrained forearm postures based on those of the trained posture. If the time for data collection is limited, it is preferable to focus on variations in forearm rotation angle.
机构:
West China Hosp Sichuan Univ, Natl Clin Res Ctr Geriatr, Chengdu, Sichuan, Peoples R China
Sichuan Univ, Medx Ctr Mfg, Chengdu, Sichuan, Peoples R ChinaWest China Hosp Sichuan Univ, Natl Clin Res Ctr Geriatr, Chengdu, Sichuan, Peoples R China
He, Jiayuan
Jiang, Ning
论文数: 0引用数: 0
h-index: 0
机构:
West China Hosp Sichuan Univ, Natl Clin Res Ctr Geriatr, Chengdu, Sichuan, Peoples R China
Sichuan Univ, Medx Ctr Mfg, Chengdu, Sichuan, Peoples R ChinaWest China Hosp Sichuan Univ, Natl Clin Res Ctr Geriatr, Chengdu, Sichuan, Peoples R China
机构:
Emory Univ, Dept Orthopaed Surg, Div Upper Extrem Surg, 59 Execut Pk South, Atlanta, GA 30329 USAEmory Univ, Dept Orthopaed Surg, Div Upper Extrem Surg, 59 Execut Pk South, Atlanta, GA 30329 USA
Wagner, Eric R.
Gottschalk, Michael B.
论文数: 0引用数: 0
h-index: 0
机构:
Emory Univ, Dept Orthopaed Surg, Div Upper Extrem Surg, 59 Execut Pk South, Atlanta, GA 30329 USAEmory Univ, Dept Orthopaed Surg, Div Upper Extrem Surg, 59 Execut Pk South, Atlanta, GA 30329 USA
机构:
Univ Colorado, Anschutz Med Ctr, Dept Surg, Div Plast & Reconstruct Surg, 12631 East 17th Ave,C309 Room 6414, Aurora, CO 80045 USA
Univ Colorado, Anschutz Med Ctr, Dept Orthoped, 12631 East 17th Ave,C309 Room 6414, Aurora, CO 80045 USAUniv Colorado, Anschutz Med Ctr, Dept Surg, Div Plast & Reconstruct Surg, 12631 East 17th Ave,C309 Room 6414, Aurora, CO 80045 USA
机构:
Mayo Clin, Dept Orthoped Surg, Div Hand & Microsurg, Jacksonville, FL 32224 USAMayo Clin, Dept Orthoped Surg, Div Hand & Microsurg, Jacksonville, FL 32224 USA