Modulation strategy for single-phase high-frequency isolated direct AC-AC converter to eliminate voltage spike

被引:0
|
作者
Wu F. [1 ]
Bu H. [1 ]
Zhang R. [1 ]
机构
[1] School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin
基金
中国国家自然科学基金;
关键词
Direct AC-AC conversion; Electric converters; Isolated; Modulation strategy; Voltage spike;
D O I
10.16081/j.epae.202009007
中图分类号
学科分类号
摘要
Conventional modulation strategies for high-frequency isolated direct AC-AC converters generate voltage spikes, which may cause significant safety hazards. The essential reason that traditional phase-shift modulation strategy generates voltage spike is analyzed, i.e. the smooth transition from transformer current to output side inductor current can't be guaranteed. On this basis, a novel modulation strategy is proposed, in which the primary side uses pulse width modulation control and the secondary side uses power frequency synchronous control. In each switching cycle, the transformer current is equal to the output side inductor current before the transition from the freewheeling state to the power transmission state, so as to avoid the sudden change of current and completely eliminate the voltage spike. The detailed experimental results demonstrate the correctness and feasibility of the proposed modulation strategy. © 2020, Electric Power Automation Equipment Press. All right reserved.
引用
收藏
页码:169 / 174
页数:5
相关论文
共 18 条
  • [1] LIU Chuang, QI Ruipeng, LIU Haijun, Et al., Method of de-creasing intermediate DC-link capacitors for three-phase cascaded power electronics transformers, Electric Power Automation Equipment, 37, 11, pp. 46-53, (2017)
  • [2] WANG Hui, TAN Xingguo, LI Qingmin, Et al., Development and applicability analysis of intelligent solid state transformer, 2011 4th International Conference on Electric Utility Dere-gulation and Restructuring and Power Technologies(DRPT), pp. 1150-1154, (2011)
  • [3] MANJREKAR M D, KIEFERNDORF R, VENKATARAMANAN G., Power electronic transformers for utility applications, 2000 IEEE Industry Applications Conference, pp. 2496-2502, (2000)
  • [4] JI Zhendong, SUN Yichao, JIN Cheng, Et al., Multi DC voltages balancing control method for cascaded solid state transformer with delta configuration, Electric Power Automation Equipment, 38, 9, pp. 54-61, (2018)
  • [5] HUBER J E, KOLAR J W., Solid-state transformers: on the origins and evolution of key concepts, IEEE Industrial Electronics Magazine, 10, 3, pp. 19-28, (2016)
  • [6] HUANG Kun, HAO Sipeng, SONG Gang, Et al., Layered optimization of AC/DC hybrid microgrid with three-port power electronic transformer, Electric Power Automation Equipment, 40, 3, pp. 37-43, (2020)
  • [7] BIFARETTI S, ZANCHETTA P, WATSON A, Et al., Advanced power electronic conversion and control system for universal and flexible power management, IEEE Transactions on Smart Grid, 2, 2, pp. 231-243, (2011)
  • [8] WANG Zhe, LI Yaohua, LI Zixin, Et al., Design method of capacitance value of three-phase cascaded H-bridge power electronic transformer, Electric Power Automation Equipment, 40, 1, pp. 219-224, (2020)
  • [9] LAI Rixin, WANG Fei, BURGOS R, Et al., A systematic topology evaluation methodology for high-density three-phase PWM AC-AC converters, IEEE Transactions on Power Electronics, 23, 6, pp. 512-517, (2008)