Assessment of intraocular foreign body using high resolution 3D ultrasound imaging

被引:1
|
作者
Minhaz, Ahmed Tahseen [1 ]
Orge, Faruk H. [2 ,5 ]
Wilson, David L. [1 ,4 ]
Bayat, Mahdi [3 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Ophthalmol & Visual Sci, Cleveland, OH USA
[3] Case Western Reserve Univ, Dept Elect Comp & Syst Engn, Cleveland, OH USA
[4] Case Western Reserve Univ, Dept Radiol, Cleveland, OH USA
[5] Univ Hosp, Dept Pediat Ophthalmol & Adult Strabismus, Cleveland, OH USA
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
BODIES;
D O I
10.1038/s41598-024-62362-y
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Ocular trauma often involves intraocular foreign bodies (IOFBs) that pose challenges in accurate diagnosis due to their size, shape, and material composition. In this study, we proposed a novel whole-eye 3D ophthalmic ultrasound B-scan (3D-UBS) system for automating image acquisition and improved 3D visualization, thereby improving sensitivity for detecting IOFBs. 3D-UBS utilizes 14 MHz Clarius L20 probe, a motorized translation stage, and a surgical microscope for precise placement and movement. The system's 3D point spread function (PSF) is 0.377 x 0.550 x 0.894 mm3 characterized by the full-width at half-maximum intensity values in the axial, lateral and elevation directions. Digital phantom and ex vivo ocular models were prepared using four types of IOFBs (i.e., plastic, wood, metal, and glass). Ex vivo models were imaged with both 3D-UBS and clinical computed tomography (CT). Image preprocessing was performed on 3D-UBS images to remove uneven illumination and speckle noise. Multiplanar reformatting in 3D-UBS provides optimal plane selection after acquisition, reducing the need for a trained ultrasonographer. 3D-UBS outperforms CT in contrast for wood and plastic, with mean contrast improvement of 2.43 and 1.84 times, respectively. 3D-UBS was able to identify wood and plastic IOFBs larger than 250 mu m and 300 in diameter, respectively. CT, with its wider PSF, was only able to detect wood and plastic IOFBs larger than 600 and 550 mu m, respectively. Although contrast was higher in CT for metal and glass IOFBs, 3D-UBS provided sufficient contrast to identify those. 3D-UBS provides an easy-to-use, non-expert imaging approach for identifying small IOFBs of different materials and related ocular injuries at the point of care.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Assessment of ocular injuries using high-resolution 3D ultrasound
    Minhaz, Ahmed Tahseen
    Orge, Faruk H.
    Wilson, David L.
    Bayat, Mahdi
    [J]. MEDICAL IMAGING 2024: ULTRASONIC IMAGING AND TOMOGRAPHY, 2024, 12932
  • [2] 3D imaging of teeth using high frequency ultrasound
    Hughes, David A.
    Button, Tim W.
    Cochran, Sandy
    Elgoyhen, Jocelyn
    Girkin, John M.
    Hughes, Hana
    Longbottom, Christopher
    Meggs, Carl
    Poland, Simon
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 327 - +
  • [3] 3D ultrasound biomicroscopy (3D-UBM) imaging of the eye for unique 3D assessment of ciliary body
    Minhaz, Ahmed Tahseen
    Wu, Hao
    Helms, Richard W.
    Sevgi, Duriye Damla
    Kim, Alvin
    Kwak, Sunwoo
    Orge, Faruk H.
    Wilson, David L.
    [J]. MEDICAL IMAGING 2020: ULTRASONIC IMAGING AND TOMOGRAPHY, 2020, 11319
  • [4] Resolution assessment of a 3D Ultrasound Computer Tomograph using Ellipsoidal Backprojection
    Scliwarzenberg, G. F.
    Stotzka, R.
    Zapf, A.
    Genimeke, H.
    Ruiter, N. V.
    [J]. 2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 1979 - 1982
  • [5] Detection of intraocular foreign body with ultrasound
    Goksu, E.
    Nokay, A. E.
    Sayrac, A. V.
    Kartal, M.
    Kilic, T.
    [J]. HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2014, 21 (02) : 88 - 91
  • [6] Elevation Resolution Enhancement Oriented 3D Ultrasound Imaging
    Fan, Kai
    Cai, Yunye
    Shen, Enxiang
    Wang, Yuxin
    Yuan, Jie
    Tao, Chao
    Liu, Xiaojun
    [J]. ULTRASONIC IMAGING, 2024, 46 (4-5) : 220 - 232
  • [7] A method for 3D measurement with high resolution using ultrasound spherical waves
    Matani, A
    Nambu, M
    Kondo, A
    Oshiro, O
    Chihara, K
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (5B): : 3255 - 3259
  • [8] 3D In Vitro Ultrasound Super-Resolution Imaging using a Clinical System
    Christensen-Jeffries, Kirsten
    Harput, Sevan
    Brown, Jemma
    Zhang, Ge
    Zhu, Jiaqi
    Tang, Meng-Xing
    Dunsby, Christopher
    Eckersley, Robert
    [J]. 2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [9] High-resolution 3D MR imaging of aging ciliary body and lens
    Strenk, SA
    Jacob, J
    Strenk, LM
    Alvarez, T
    Semmlow, JL
    DeMarco, JK
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4567 - 4567
  • [10] Ovarian assessment using deep learning based 3D ultrasound super resolution
    Gupta, Saumya
    Suryanarayana, Venkata K.
    Kudavelly, Srinivas Rao
    Ramaraju, G. A.
    [J]. MEDICAL IMAGING 2021: COMPUTER-AIDED DIAGNOSIS, 2021, 11597