Axial compression behavior of prefabricated T-section thin concrete encased steel short columns

被引:1
|
作者
Meng, Kun [1 ]
Chen, Xuesen [1 ]
Liu, Xue Chun [1 ]
Zhang, Dong Jie [2 ]
Zhang, Ai Lin [1 ]
Ren, Yang Zhi [1 ]
Xu, Bin [3 ]
Yin, Zheng [3 ]
机构
[1] Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prestr, Beijing 100124, Peoples R China
[2] Beijing Inst Technol, Zhuhai 519088, Peoples R China
[3] China Railway Construct Grp Co Ltd, Beijing 100131, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
T-section column; Concrete encased steel; Axial compression resistance; Confined concrete; Axial stiffness; L-SHAPED COLUMNS; SEISMIC PERFORMANCE; MECHANICAL PROPERTY; CAPACITY; MODEL;
D O I
10.1016/j.jobe.2023.108108
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A T-section thin concrete encased steel (T-TCES) column is proposed for the residual buildings, avoiding the convex corners in rooms. The required concrete cover thickness for concrete encased steel members specified in the existing codes is quite large, which is the key problem and to be solved in the proposed column by reducing the concrete covers, facilitating the transportation and installation. To evaluate the mechanical performances of the proposed columns, especially the local stability of the internal T-section steel with the obviously reduced concrete covers, tests of nine short column specimens were conducted under axial monotonic loading. Also, the finite element (FE) analysis was conducted and validated. The effect of the proportion of steel sectional area, concrete strength, stirrup spacing and the concrete encasement thickness outside the flange on the failure modes, load-displacement responses, load-strain responses and characteristic loads were obtained. According to the test and FE analysis results, the peak load can be improve by increasing concrete strength or the proportion of steel sectional area or decreasing the stirrup spacing. The T-TCES columns with low-grade concrete or small stirrup spacing or high proportion of steel sectional area have a better composite action between the internal steel and concrete. Increasing the thickness of the concrete encasement outside the flange can prevent the T-TCES column from cracking. The concrete encasement and reinforcement bars can restrain the internal steel buckling, and improve the steel strength of the composite column compared with the steel column. The calculation methods for the peak and design resistances of the T-TCES column were proposed and proved to show satisfactory accuracy. The simplified model of the load- displacement responses and the calculation methods of the axial stiffness are proposed and validated against the test results.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Axial compression behavior of prefabricated L-section thin concrete encased steel short columns
    Liu, Xue-Chun
    Meng, Kun
    Chen, Xuesen
    Zhang, Jing
    Cui, Yue
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 208
  • [2] Axial compression behavior of a prefabricated F4T-section thin concrete encased steel short columns with different stirrup types
    Jin, Bowen
    Liu, Xuechun
    Chen, Xuesen
    Zhang, Dongjie
    Zhang, Jing
    Li, Zhaoqi
    STRUCTURES, 2024, 65
  • [3] Axial compression behavior of prefabricated cruciform-section thin-concrete-encased steel short column
    Liu, Xue Chun
    Liu, Yu Kun
    Chen, Xuesen
    Li, Chuan Hao
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 217
  • [4] Behavior of prefabricated cruciform thin concrete cover encased steel column under axial compression
    Liu, Xue-Chun
    Meng, Kun
    Chen, Xuesen
    Zhang, Dong-Jie
    Kong, De-Shang
    Ren, Yang-Zhi
    Zhang, Jing
    Cui, Yue
    STRUCTURES, 2024, 66
  • [5] Axial compression behavior of concrete-encased cellular steel columns
    Anuntasena, Worakarn
    Lenwari, Akhrawat
    Thepchatri, Thaksin
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 172
  • [6] Experimental study on axial compression performance of T-section concrete filled steel and FRP tubular composite columns
    Shen G.
    Qi Y.
    Lu J.
    Shen Z.
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2022, 39 (07): : 3395 - 3410
  • [7] Strength and post-yield behavior of T-section steel encased by structural concrete
    Nzabonimpa, J. D.
    Hong, Won-Kee
    Kim, Jisoon
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2018, 27 (05):
  • [8] Axial compressive behavior of prefabricated T4-shaped thin concrete cover encased steel column
    Liu, Xue-Chun
    Meng, Kun
    Chen, Xuesen
    Zhang, Dong-Jie
    Ren, Yang-Zhi
    Xu, Bin
    Yin, Zheng
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 219
  • [9] Study on behavior of partially prefabricated steel reinforced concrete stub columns under axial compression
    Yang, Yong
    Chen, Yang
    Feng, Shiqiang
    ENGINEERING STRUCTURES, 2019, 199
  • [10] Mechanical Behavior of Steel-encased Concrete Filled Prefabricated FRP Tubes Short Column under Axial Compression Based on ABAQUS
    Zhang, Haixia
    Cao, Pengpeng
    Yao, Jing
    Feng, Chen
    ADVANCES IN CIVIL ENGINEERING II, PTS 1-4, 2013, 256-259 : 749 - 753