Low-cost sensor-based investigation of CO2 and volatile organic compounds in classrooms: Exploring dynamics, ventilation effects and perceived air quality relations

被引:1
|
作者
Sorensen, Sara Bjerre [1 ]
Kristensen, Kasper [1 ]
机构
[1] Aarhus Univ, Dept Biol & Chem Engn, Aarhus, Denmark
关键词
Indoor air quality (IAQ); GC-MS; Schools; Total volatile organic compound (TVOC); Citizen science; CARBON-DIOXIDE; EXCHANGE-RATE; INDOOR; EXPOSURE; SCHOOLS; HEALTH; FORMALDEHYDE; PERFORMANCE; SYMPTOMS; OZONE;
D O I
10.1016/j.buildenv.2024.111369
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Poor classroom air quality (CAQ) can have negative impacts on student health, well-being and performance. Although CO2 concentrations are the proxy most often applied when assessing classroom ventilation and air quality, volatile organic compounds (VOCs) are important contributors to classroom air pollution. However, little is known about the sources and dynamics of VOCs in classrooms and its relation to classroom occupancy, ventilation and perceived air quality. In this study, CAQ was investigated in 75 Danish classrooms throughout November 2021 using low-cost sensors for continuous measurements of occupancy, CO2- and total volatile organic compound (TVOC) concentrations in conjunction with thermal desorption gas chromatography mass spectrometry (TD-GC-MS) analysis of organic compounds. Measurements show significant increases in TVOC concentrations during school hours as well as a day-to-day increase in the morning TVOC levels from insufficient ventilation from preceding days. A weak (r = 0.21) but significant (p < 0.01) correlation was found between classroom CO2 and TVOC. However, unlike the CO2 concentrations, TVOC concentrations were affected by episodic emissions from classroom activities. Ventilation type was identified as a key factor influencing both CO2- and TVOC levels. Although mechanically ventilated classrooms experienced significantly lower CO2- and TVOC levels compared to naturally ventilated classrooms, all classrooms exceeded guideline values of 1000 ppm CO2 with 70% of the classrooms exceeding this more than half of the occupied time. In contrast to CO2, a positive correlation was identified between the median TVOC concentrations during occupancy and the reported perceived CAQ.
引用
收藏
页数:12
相关论文
共 17 条
  • [1] Evaluation of sensor-based low-cost devices for Indoor Air Quality (IAQ) measurement
    Schuldt, T.
    Schmidt, F.
    [J]. GEFAHRSTOFFE REINHALTUNG DER LUFT, 2019, 79 (1-2): : 7 - 12
  • [2] New cellulose based ionic compounds as low-cost sorbents for CO2 capture
    Bernard, Franciele L.
    Rodrigues, Daniela. M.
    Polesso, Barbara B.
    Donato, Augusto J.
    Seferin, Marcus
    Chaban, Vitaly V.
    Dalla Vecchia, Felipe
    Einloft, Sandra
    [J]. FUEL PROCESSING TECHNOLOGY, 2016, 149 : 131 - 138
  • [3] VENTILATION CONTROL BASED ON THE CO2 AND AEROSOL CONCENTRATION AND THE PERCEIVED AIR QUALITY MEASUREMENTS - A CASE STUDY
    Polednik, Bernard
    Dudzinska, Marzenna
    [J]. ARCHIVES OF ENVIRONMENTAL PROTECTION, 2010, 36 (04) : 67 - 80
  • [4] The BErkeley Atmospheric CO2 Observation Network: field calibration and evaluation of low-cost air quality sensors
    Kim, Jinsol
    Shusterman, Alexis A.
    Lieschke, Kaitlyn J.
    Newman, Catherine
    Cohen, Ronald C.
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2018, 11 (04) : 1937 - 1946
  • [5] Lignin-Based Platform as a Potential Low-Cost Sorbent for the Direct Air Capture of CO2
    Carrier, Jake
    Lai, Cheng-Yu
    Radu, Daniela
    [J]. ACS ENVIRONMENTAL AU, 2024, 4 (04): : 196 - 203
  • [6] Indoor Air Quality Monitoring (IAQ): A Low-Cost Alternative to CO2 Monitoring in Comparison to an Industry Standard Device
    Thomas, Darshana
    Mistry, Bhumika
    Snow, Steven
    Schraefel, M. C.
    [J]. INTELLIGENT COMPUTING, VOL 1, 2019, 858 : 1010 - 1027
  • [7] Field calibration of a cluster of low-cost commercially available sensors for air quality monitoring. Part B: NO, CO and CO2
    Spinelle, Laurent
    Gerboles, Michel
    Villani, Maria Gabriella
    Aleixandre, Manuel
    Bonavitacola, Fausto
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 238 : 706 - 715
  • [8] Calibration of CO, NO2, and O3 Using Airify: A Low-Cost Sensor Cluster for Air Quality Monitoring
    Ionascu, Marian-Emanuel
    Castell, Nuria
    Boncalo, Oana
    Schneider, Philipp
    Darie, Marius
    Marcu, Marius
    [J]. SENSORS, 2021, 21 (23)
  • [9] Air quality in schools -: Classroom levels of carbon Dioxide(CO2), volatile organic compounds (VOC), aldehydes, endotoxins and cat allergen
    Fromme, H.
    Heitmann, D.
    Dietrich, S.
    Schierl, R.
    Koerner, W.
    Kiranoglu, M.
    Zapf, A.
    Twardella, D.
    [J]. GESUNDHEITSWESEN, 2008, 70 (02) : 88 - 97
  • [10] A low-cost in-situ CO2 sensor based on a membrane and NDIR for long-term measurement in seawater
    Meng Li
    Baolu Du
    Jinjia Guo
    Zhihao Zhang
    Zeyu Lu
    Rong’er Zheng
    [J]. Journal of Oceanology and Limnology, 2022, 40 : 986 - 998