Combining use of natural ventilation, external shading, cool roof and thermal mass to improve indoor thermal environment: Field measurements and simulation study

被引:1
|
作者
Li, Yongcai [1 ]
Tao, Xiaohan [1 ]
Zhang, Yaqin [2 ]
Li, Wuyan [3 ]
机构
[1] Chongqing Univ, Sch Civil Engn, Chongqing 40045, Peoples R China
[2] Gen Res Inst Architecture & Planning Design Co Ltd, Chongqing 400045, Peoples R China
[3] Kunming Univ Sci & Technol, Fac Civil Engn & Mech, Yunnan Key Lab Disaster Reduct Civil Engn, Kunming 650500, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Natural ventilation; Thermal mass; Cool roof; External shading; Indoor air temperature; SOLAR CHIMNEY; DAYLIGHTING PERFORMANCE; RESIDENTIAL BUILDINGS; ENERGY; IMPACT; CLIMATE; AIR; OPTIMIZATION; WARM;
D O I
10.1016/j.jobe.2024.108904
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Thermal mass, natural ventilation, external shading and cool roof are commonly regarded as passive cooling measures. Combined use of these passive cooling measures could achieve a more comfortable indoor environment, and further reduce the building energy demand. The aim of this paper was to assess the short and long-term performances of individual and combination passive measures in a cooling -dominated region of China experimentally and numerically. The field measurement revealed that natural ventilation, external shading and cool roof can reduce the internal wall and indoor air temperatures. The mean air temperatures in the test chamber were 1.3, 2.0, and 1.1 degrees C lower than that in reference chamber. The combined use of natural ventilation, external shading and cool roof can maintain the daily indoor air temperature within the range of 26.2 and 28.1 degrees C. The mean air temperature in the test chamber was reduced by 2.8 degrees C. Long-term simulation results confirmed that applying combination mode of natural ventilation, cool roof and external shading, the indoor temperature, varying from 21.9 to 28.1 degrees C, is greatly improved compared with the case operated natural ventilation only, particularly during peak temperature hours. The effect of specific heat capacity on indoor air temperature is complex. Increasing the specific heat is not always beneficial to indoor thermal environment. Further, the greater the heat transfer coefficient leads to the higher indoor air temperature through entire summer. The maximum indoor air temperature is reduced by 2.6 degrees C when the heat transfer coefficient changes from 1.0 to 0.1 W/m2 center dot K.
引用
下载
收藏
页数:19
相关论文
共 8 条
  • [1] Comparative Study of Numerical Simulation of Indoor Thermal Environment in the Pattern of Personalized Ventilation and Stratum Ventilation
    Liu, Taishun
    Liu, Zeqin
    Li, Ge
    Zuo, Zhenjun
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 785 - 791
  • [2] Will cool roofs improve the thermal performance of our built environment? A study assessing roof systems in Bahrain
    Radhi, Hassan
    Sharpies, Stephen
    Taleb, Hanan
    Fahmy, Mohammad
    ENERGY AND BUILDINGS, 2017, 135 : 324 - 337
  • [3] Exploring the impact of opening ratio on indoor thermal environment: A study on natural ventilation design
    Shimonosono, Kei
    Sasaki, Yuji
    Kohri, Kimiko
    JAPAN ARCHITECTURAL REVIEW, 2023, 6 (01)
  • [4] Study on indoor thermal environment of office space controlled by cooling panel system using field measurement and the numerical simulation
    Kim, T
    Kato, S
    Murakami, S
    Rho, J
    BUILDING AND ENVIRONMENT, 2005, 40 (03) : 301 - 310
  • [5] Passive cooling and natural ventilation by the windcatcher (Badgir): An experimental and simulation study of indoor air quality, thermal comfort and passive cooling power
    Nejat, Payam
    Ferwati, M. Salim
    Calautit, John
    Ghahramani, Ali
    Sheikhshahrokhdehkordi, Mohammadamin
    JOURNAL OF BUILDING ENGINEERING, 2021, 41
  • [6] Characterizing indoor air quality, thermal environment and window opening in natural-ventilated Norwegian bedrooms: An extensive field study
    Heide, Vegard
    Georges, Laurent
    Breesch, Hilde
    BUILDING AND ENVIRONMENT, 2023, 246
  • [7] Assessment of Floor-Level Impact on Natural Ventilation and Indoor Thermal Environment in Hot–Humid Climates: A Case Study of a Mid-Rise Educational Building
    Mba, Emeka J.
    Oforji, Peter I.
    Okeke, Francis O.
    Ozigbo, Ikechukwu W.
    Onyia, Chinyelu D. F.
    Ozigbo, Chinelo A.
    Ezema, Emmanuel C.
    Awe, Foluso C.
    Nnaemeka-Okeke, Rosemary C.
    Onyia, Stephanie C.
    Buildings, 2025, 15 (05)
  • [8] THE EFFECTS OF OPENING RATIO ON THE INDOOR THERMAL ENVIRONMENT AND VALIDITY VERIFICATION OF METHOD OF THE OPENING RATIO CALCULATION Study on the performance evaluation of natural ventilation control in office buildings (Part 4)
    Shimonosono K.
    Kohri K.
    Ishino H.
    Journal of Environmental Engineering (Japan), 2022, 87 (801): : 731 - 741