Line identification of boron and nitrogen emissions in extreme-and vacuumultraviolet wavelength ranges in the impurity powder dropping experiments of the Large Helical Device and its application to spectroscopic diagnostics

被引:0
|
作者
大石鉄太郎 [1 ,2 ]
芦川直子 [1 ,2 ]
Federico NESPOLI [3 ]
増崎貴 [1 ,2 ]
庄司主 [1 ]
Eric P GILSON [3 ]
Robert LUNSFORD [3 ]
森田繁 [1 ,2 ]
後藤基志 [1 ,2 ]
川本靖子 [1 ]
鈴木千尋 [1 ,2 ]
孙震 [3 ]
Alex NAGY [3 ]
David A GATES [3 ]
森崎友宏 [1 ,2 ]
机构
[1] National Institute for Fusion Science, National Institutes of Natural Sciences
[2] Department of Fusion Science, The Graduate University for Advanced Studies
[3] Princeton Plasma Physics
关键词
D O I
暂无
中图分类号
TL612 [];
学科分类号
摘要
An impurity powder dropper was installed in the 21 st campaign of the Large Helical Device experiment(Oct. 2019–Feb. 2020) under a collaboration between the National Institute for Fusion Science and the Princeton Plasma Physics Laboratory for the purposes of real-time wall conditioning and edge plasma control. In order to assess the effective injection of the impurity powders,spectroscopic diagnostics were applied to observe line emission from the injected impurity. Thus,extreme-ultraviolet(EUV) and vacuum-ultraviolet(VUV) emission spectra were analyzed to summarize observable impurity lines with B and BN powder injection. Emission lines released from B and N ions were identified in the EUV wavelength range of 5–300 ? measured using two grazing incidence flat-field EUV spectrometers and in the VUV wavelength range of 300–2400 ? measured using three normal incidence 20 cm VUV spectrometers. BI–BV and NIII–NVII emission lines were identified in the discharges with the B and BN powder injection, respectively. Useful B and N emission lines which have large intensities and are isolated from other lines were successfully identified as follows: BI(1825.89, 1826.40) ?(blended), BII 1362.46 ?, BIII(677.00, 677.14,677.16) ?(blended), BIV 60.31 ?, BV 48.59 ?, NIII(989.79, 991.51, 991.58) ?(blended), NIV765.15 ?, NV(209.27, 209.31) ?(blended), NVI 1896.80 ?, and NVII 24.78 ?. Applications of the line identifications to the advanced spectroscopic diagnostics were demonstrated, such as the vertical profile measurements for the BV and NVII lines using a space-resolved EUV spectrometer and the ion temperature measurement for the BII line using a normal incidence 3 m VUV spectrometer.
引用
收藏
页码:10 / 21
页数:12
相关论文
共 2 条
  • [1] Line identification of boron and nitrogen emissions in extreme-and vacuumultraviolet wavelength ranges in the impurity powder dropping experiments of the Large Helical Device and its application to spectroscopic diagnostics
    大石鉄太郎
    芦川直子
    Federico NESPOLI
    増崎貴
    庄司主
    Eric P GILSON
    Robert LUNSFORD
    森田繁
    後藤基志
    川本靖子
    鈴木千尋
    孙震
    Alex NAGY
    David A GATES
    森崎友宏
    Plasma Science and Technology, 2021, 23 (08) : 10 - 21
  • [2] Line identification of boron and nitrogen emissions in extreme- and vacuum-ultraviolet wavelength ranges in the impurity powder dropping experiments of the Large Helical Device and its application to spectroscopic diagnostics
    Oishi, Tetsutarou
    Ashikawa, Naoko
    Nespoli, Federico
    Masuzaki, Suguru
    Shoji, Mamoru
    Gilson, Eric P.
    Lunsford, Robert
    Morita, Shigeru
    Goto, Motoshi
    Kawamoto, Yasuko
    Suzuki, Chihiro
    Sun, Zhen
    Nagy, Alex
    Gates, David A.
    Morisaki, Tomohiro
    PLASMA SCIENCE & TECHNOLOGY, 2021, 23 (08)