Impact of load impedance on the performance of a thermoacoustic system employing acoustic pressure amplifier附视频

被引:0
|
作者
Ke TANG Zhongjie HUANG Tao JIN Guobang CHEN Institute of Refrigeration and Cryogenics Zhejiang University Hangzhou China [310027 ]
机构
关键词
Thermoacoustic engine; Acoustic pressure amplifier (APA); Thermoacoustics;
D O I
暂无
中图分类号
TB51 [声学仪器];
学科分类号
0804 ;
摘要
An acoustic pressure amplifier (APA) is capable of improving the match between a thermoacoustic engine and a load by elevating pressure ratio and acoustic power output. A standing-wave thermoacoustic engine driving a resistance- and-compliance (RC) load through an APA was simulated with linear thermoacoustics to study the impact of load impedance on the performance of the thermoacoustic system. Based on the simulation results, analysis focuses on the distribution of pressure amplitude and velocity amplitude in APA with an RC load of diverse acoustic resistances and compliance impedances. Variation of operating parameters, including pressure ratio, acoustic power, hot end temperature of stack, etc., versus impedance of the RC load is presented and analyzed according to the abovementioned distribution. A verifying experiment has been performed, which indicates that the simulation can roughly predict the system operation in the fundamental-frequency mode.
引用
收藏
页码:79 / 87
页数:9
相关论文
共 7 条
  • [1] Thermoacoustically driven pulse tube cooler below 60<ce:hsp sp="0.25"/>K[J] . K. Tang,R. Bao,G.B. Chen,Y. Qiu,L. Shou,Z.J. Huang,T. Jin.Cryogenics . 2007 (9)
  • [2] An energy-focused thermoacoustic-Stirling heat engine reaching a high pressure ratio above 1.40[J] . G.Y. Yu,E.C. Luo,W. Dai,Z.H. Wu.Cryogenics . 2007 (2)
  • [3] A heat-driven thermoacoustic cryocooler capable of reaching below liquid hydrogen temperature[J] . JianYing Hu,ErCang Luo,Wei Dai,Yuan Zhou.Chinese Science Bulletin . 2007 (4)
  • [4] Effect of RC load on performance of thermoacoustic engine
    Bao, R.
    Chen, G. B.
    Tang, K.
    Jia, Z. Z.
    Cao, W. H.
    [J]. CRYOGENICS, 2006, 46 (09) : 666 - 671
  • [5] Performance comparison of thermoacoustic engines with constant-diameter resonant tube and tapered resonant tube
    Tang, K.
    Chen, G. B.
    Jin, T.
    Bao, R.
    Li, X. M.
    [J]. CRYOGENICS, 2006, 46 (10) : 699 - 704
  • [6] Influence of resonance tube length on performance of thermoacoustically driven pulse tube refrigerator[J] . K. Tang,G.B. Chen,T. Jin,R. Bao,B. Kong,L.M. Qiu.Cryogenics . 2004 (3)
  • [7] A 115 K thermo acoustically driven pulse tube refrigerator with low onset temperature
    Tang, K
    Chen, GB
    Kong, B
    [J]. CRYOGENICS, 2004, 44 (05) : 287 - 291