Discrepancy of blood pressure between the brachial artery and radial artery

被引:0
|
作者
Wenyuan Li [1 ]
Xiaohai Wang [2 ]
Lichong Lu [3 ]
Hao Li [4 ]
机构
[1] Department of Anesthesiology,Second Affiliated Hospital of Nanjing Medical University
[2] Department of Anesthesiology,Affiliated Drum-Tower Hospital of Medical College of Nanjing University
[3] Department of Cardio-Thoracic Surgery,Affiliated Drum-Tower Hospital of Medical College of Nanjing University
[4] Department of Anesthesiology,First People's Hospital of
关键词
D O I
暂无
中图分类号
学科分类号
摘要
BACKGROUND:In this study,we attempted to find the relations between blood pressure(BP)measured on the brachial artery(bBP) and BP assessed on the radial artery(rBP) in the right arm.METHODS:Three hundred and fifteen patients were enrolled in this study.Those who had peripheral vascular disease,wounds of arm skin or subcutaneous tissue infection were excluded.After a 15-minute equilibration and stabilization period after inducation of anesthesia,three bBP and rBP records were obtained sequentially using an oscillometric device with an adult cuff and infant cuff,respectively.Order for each BP was randomized.RESULTS:The bBP was significantly lower than the rBP(P<0.05).The difference between the two values varied from 13 to 18 mmHg in systolic BP(SBP),diastolic BP(DBP) and mean blood pressure(MAP) respectively.And the rBP was positively correlated with the bBP(r=0.872,0.754,0.765;P<0.001,<0.001,<0.001;SBP,DBP,MAP,respectively).CONCLUSION:The bBP value can be evaluated by the noninvasive measurements of rBP using an appropriate cuff in clinical practice.
引用
收藏
页码:294 / 297
页数:4
相关论文
共 50 条
  • [1] Discrepancy of blood pressure between the brachial artery and radial artery
    Wen-yuan Li
    Xiao-hai Wang
    Li-chong Lu
    Hao Li
    [J]. World Journal of Emergency Medicine, 2013, (04) : 294 - 297
  • [2] Discrepancy of blood pressure between the brachial artery and radial artery
    Li, Wen-yuan
    Wang, Xiao-hai
    Lu, Li-chong
    Li, Hao
    [J]. WORLD JOURNAL OF EMERGENCY MEDICINE, 2013, 4 (04): : 294 - 297
  • [3] RELIABILITY OF PALPATION OF THE RADIAL ARTERY COMPARED TO AUSCULTATION OF THE BRACHIAL ARTERY IN MEASURING SYSTOLIC BLOOD PRESSURE
    Van der Hoeven, N. V.
    Van den Born, B. J. H.
    Van Montfrans, G. A.
    [J]. JOURNAL OF HYPERTENSION, 2009, 27 : S191 - S192
  • [4] Invasive monitoring of blood pressure: a radiant future for brachial artery as an alternative to radial artery catheterisation?
    Lakhal, Karim
    Robert-Edan, Vincent
    [J]. JOURNAL OF THORACIC DISEASE, 2017, 9 (12) : 4812 - 4816
  • [5] BRACHIAL AND RADIAL ARTERY CUTDOWN
    MOSS, GW
    [J]. SURGICAL CLINICS OF NORTH AMERICA, 1969, 49 (06) : 1325 - &
  • [6] Central hemodynamics and the discrepancy between central blood pressure and brachial blood pressure
    Park, Jin-Sun
    Shin, Joon-Han
    Park, Jeong-Bae
    Choi, Dong-Ju
    Youn, Ho-Joong
    Park, Chang-Gyu
    Kwan, Jun
    Ahn, Youngkeun
    Kim, Dong-Woon
    Rim, Se-Joong
    Park, Seung-Woo
    Sung, Jidong
    Bae, Jang-Ho
    [J]. MEDICINE, 2022, 101 (40) : E30484
  • [7] Discrepancy of blood pressure between arms: a case of left subclavian artery occlusion
    Yamamoto, Naoki
    Dejima, Akihiro
    Hasatani, Kenkou
    [J]. BMJ CASE REPORTS, 2021, 14 (04)
  • [8] Significance of pulsatility of brachial artery pressure for blood pressure control
    Yoshitomi, Yuji
    Ishii, Toshikazu
    Tsujibayashi, Takashi
    Kaneki, Masashi
    Sakurai, Shun-ichiro
    [J]. INTERNATIONAL HEART JOURNAL, 2008, 49 (03) : 295 - 302
  • [9] Blood Flow and Pressure in a Brachial Artery under Cuff Pressure
    Kim, Ho Jong
    Lee, Hyeon Chul
    Kim, Chul Han
    Kim, Yun Jin
    Jeon, Gye Rok
    [J]. IECON 2004: 30TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOL 3, 2004, : 2973 - 2977
  • [10] Comparison of a radial artery compression device with invasive radial artery blood pressure monitoring
    Fix, M. L.
    Listwa, T. M.
    Nelson, S. W.
    Goldstein, J. N.
    Thomas, S. H.
    [J]. ANNALS OF EMERGENCY MEDICINE, 2006, 48 (04) : S68 - S68