HIGH-FREQUENCY IMPEDANCE ANALYSIS OF QUARTZ-CRYSTAL MICROBALANCES COATED WITH CONDUCTING POLYMERS

被引:12
|
作者
TOPART, PA
NOEL, MAM
LIESS, HD
机构
[1] Fakultät für Elektrotechnik für Physik, Universität der Bundeswehr München, W-8012 Neubiberg
关键词
D O I
10.1016/0040-6090(94)90851-6
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, high frequency impedance analysis of an electrochemical quartz crystal microbalance is employed to monitor changes in the viscoelastic properties of conducting polymers. The frequency and motional inductance sensitivity measured during the electrodeposition of Cu, Ag and polypyrrole(tosylate) is compared with the theory for various quartz crystals of different cuts and fundamental resonant frequencies. It is found that changes in resonant resistance do not significantly depend on the quartzes used. It is shown that this technique is particularly appropriate for probe disparities in the morphology of conducting polymer films depending on the solvent, the size of the counteranion or the substrate. Changes in the viscoelastic properties of polypyrrole(tosylate) films up to 200-degrees-C were also investigated.
引用
收藏
页码:196 / 204
页数:9
相关论文
共 50 条
  • [1] HIGH-FREQUENCY IMPEDANCE ANALYSIS OF QUARTZ-CRYSTAL MICROBALANCES .2. ELECTROCHEMICAL DEPOSITION AND REDOX SWITCHING OF CONDUCTING POLYMERS
    TOPART, PA
    NOEL, MAM
    ANALYTICAL CHEMISTRY, 1994, 66 (18) : 2926 - 2934
  • [2] HIGH-FREQUENCY IMPEDANCE ANALYSIS OF QUARTZ-CRYSTAL MICROBALANCES .1. GENERAL-CONSIDERATIONS
    NOEL, MAM
    TOPART, PA
    ANALYTICAL CHEMISTRY, 1994, 66 (04) : 484 - 491
  • [3] HIGH-FREQUENCY PLATED QUARTZ-CRYSTAL UNITS FOR CONTROL OF COMMUNICATIONS EQUIPMENT
    SYKES, RA
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1946, 34 (02): : W92 - W92
  • [4] A new approach for an European development of high-performance quartz-crystal microbalances (QCM)
    Sekler, J
    Zwaal, A
    Boving, H
    7TH INTERNATIONAL SYMPOSIUM ON MATERIALS IN SPACE ENVIRONMENT, 1997, 399 : 179 - 181
  • [5] QUARTZ-CRYSTAL FREQUENCY STANDARDS
    GEORGE, WD
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1951, 39 (02): : 208 - 208
  • [6] Frequency interference between two quartz crystal microbalances
    Shen, F
    Lee, KH
    O'Shea, SJ
    Lu, P
    Ng, TY
    IEEE SENSORS JOURNAL, 2003, 3 (03) : 274 - 281
  • [7] Comparison of high frequency quartz crystal microbalances' (QCMs') mass sensitivities to theory
    Wallace, DA
    Wallace, SA
    OPTICAL SYSTEMS CONTAMINATION AND DEGRADATION, 1998, 3427 : 88 - 103
  • [8] Quartz Crystal Microbalances for Microscale Thermogravimetric Analysis
    Mansfield, Elisabeth
    Kar, Aparna
    Quinn, Timothy P.
    Hooker, Stephanie A.
    ANALYTICAL CHEMISTRY, 2010, 82 (24) : 9977 - 9982
  • [9] Using high-frequency quartz crystal microbalance
    Kurosawa, S
    Han, DS
    Park, JW
    Aizawa, H
    Yoshimoto, M
    Nakamura, C
    Miyake, J
    Chang, SM
    PROCEEDINGS OF THE 2001 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & PDA EXHIBITION, 2001, : 462 - 464
  • [10] HIGH-FREQUENCY PLATED QUARTZ CRYSTAL UNITS
    SYKES, RA
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1948, 36 (01): : 4 - 7