A COMPARISON OF DUAL ENERGY RADIOGRAPHY MEASUREMENTS AT THE LUMBAR SPINE AND PROXIMAL FEMUR FOR THE DIAGNOSIS OF OSTEOPOROSIS

被引:39
|
作者
GRIFFIN, MG
RUPICH, RC
AVIOLI, LV
PACIFICI, R
机构
[1] Division of Endocrinology and Bone Metabolism, Jewish Hospital of St. Louis, Washington University Medical Center, St.Louis, MO
来源
关键词
D O I
10.1210/jcem-73-6-1164
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In this study we assessed the ability of proximal femur and spine DER measurements to discriminate between control (C) and osteoporotic (OP) subjects as well as the reproducibility of the femoral DER technique. DER measurements of the proximal femur and spine (L2-L4) were obtained in 58 control (unfractured) and 54 osteoporotic (vertebral fractured) women. Linear regression analyses for each site with age suggested that density values from the Ward's triangle region explained the majority of variance due to age in the decline of bone density in both control (r = -0.45; P < 0.0005) and osteoporotic subjects (r = 0.34; P < 0.05), with similar findings for the femoral neck in OP subjects (r = -0.30; P < 0.05). No other femoral site produced a significant correlation with age, and vertebral measurements were the lowest in OP subjects (r = -0.11; P = NS). Cross-sectional rates of bone loss in each region implied that for OP subjects the Ward's triangle and femoral neck regions detected the largest amount of bone loss (0.64% and 0.38%/yr, respectively), while vertebral measurements were again the smallest (0.19%/yr). Results indicated that proximal femur measurements can be obtained with relatively good precision (coefficients of variation ranged from 1.9% for femoral neck to 3.0% for Ward's triangle). Finally, receiver operating characteristic curves revealed that both Ward's triangle and femoral neck densities were able to more successfully discriminate control from osteoporotic subjects than vertebral measurements. These data support the contention that measurement of skeletal sites rich in trabecular bone, such as the femur, are more useful for diagnosing osteoporosis than DER measurements of the lumbar spine. The data also suggest that the femur may be a better site than the lumbar spine for the clinical evaluation of osteoporosis with the DER technique.
引用
下载
收藏
页码:1164 / 1169
页数:6
相关论文
共 50 条
  • [1] THE ROLE OF DUAL-ENERGY X-RAY ABSORPTIOMETRY OF LUMBAR SPINE AND PROXIMAL FEMUR IN THE DIAGNOSIS AND FOLLOW-UP OF OSTEOPOROSIS
    RIZZOLI, R
    SLOSMAN, D
    BONJOUR, JP
    AMERICAN JOURNAL OF MEDICINE, 1995, 98 : S33 - S36
  • [2] Diagnosis of osteoporosis in clinicxal practice: A comparison of spine and proximal femur T scores
    Debiram, I
    O'Gradaigh, D
    Love, S
    Compston, J
    JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 (06) : 1183 - 1183
  • [3] TITLE: LUMBAR SPINE AND PROXIMAL FEMUR OSTEOPOROSIS DIAGNOSIS: REMS TECHNOLOGY IN A MULTICENTER CLINICAL STUDY
    Adami, Giovanni
    Arioli, Giovanni
    Bianchi, Gerolamo
    Brandi, Maria Luisa
    Caffarelli, Carla
    Cavalli, Loredana
    Matucci-Cerinic, Marco
    Cianferotti, Luisella
    Conversano, Francesco
    Di Paola, Marco
    Gatti, Davide
    Girasole, Giuseppe
    Giusti, Andrea
    Gonnelli, Stefano
    Manfedini, Monica
    Muratore, Maurizio
    Nuti, Ranuccio
    Pisani, Paola
    Quarta, Laura
    Viapiana, Ombretta
    ANNALS OF THE RHEUMATIC DISEASES, 2019, 78 : 933 - 933
  • [4] A comparison of dual energy x-ray absorptiometry measurement at the lumbar spine and proximal femur for postmenopausal women
    Salamat, M. R.
    Farzaneh, S. R.
    Zeyaei, H. R.
    Bagheri, M. Mir
    Company, K.
    OSTEOPOROSIS INTERNATIONAL, 2006, 17 : 384 - 384
  • [5] A comparison of dual-energy X-ray absorptiometry measurement at the lumbar spine and proximal femur for postmenopausal women
    Salamt, M. R.
    Farzaneh, S. R.
    Zeyaei, H. R.
    Mir Bagheri, M.
    Kompany, K.
    Mojahedi, T.
    Bateni, N.
    OSTEOPOROSIS INTERNATIONAL, 2006, 17 : S304 - S304
  • [6] A comparison of lumbar spine quantitative computed tomography and dual energy x-ray absorbtiometry measurements of femur neck and spine.
    Calguneri, M
    Ariyurek, M
    Gunes, D
    Ertenli, I
    Kiraz, S
    Bilgen, SA
    Ozturk, MA
    JOURNAL OF BONE AND MINERAL RESEARCH, 2003, 18 : S316 - S316
  • [7] A comparison of DXA measurement at the lumbar spine and proximal femur for premenopausal women
    Salamat, M. R.
    Farzaneh, S. R.
    Salari, A. H.
    Ziaei, H. R.
    Mir Bagheri, M.
    Company, K.
    OSTEOPOROSIS INTERNATIONAL, 2007, 18 : S52 - S53
  • [8] Influence of osteoarthrosis, osteoporosis, and rheumatoid arthritis at precision of osteodensitometry of lumbar spine and proximal femur
    Martini, F
    Tröndle, S
    Sell, S
    Mayer, F
    Willms, R
    Teschner, M
    ZEITSCHRIFT FUR RHEUMATOLOGIE, 1999, 58 (05): : 283 - 288
  • [9] DXA Scanning of the Lumbar Spine and Proximal Femur
    Berry, Matthew E.
    RADIOLOGIC TECHNOLOGY, 2018, 89 (05) : 509 - 515
  • [10] DUAL-ENERGY X-RAY ABSORPTIOMETRY IN THE LUMBAR SPINE, PROXIMAL FEMUR AND DISTAL RADIUS IN CHILDREN
    TSUKAHARA, H
    SUDO, M
    UMEZAKI, M
    HIRAOKA, M
    YAMAMOTO, K
    ISHII, Y
    HARUKI, S
    PEDIATRIC RADIOLOGY, 1992, 22 (08) : 560 - 562