TRITIUM MONITORING-SYSTEM FOR NEAR AMBIENT MEASUREMENTS

被引:4
|
作者
FALTER, KG
BAUER, ML
机构
[1] Instrumentation and Controls Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, 37831–6006
关键词
D O I
10.1109/23.159741
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes the current status of research on an improved tritium measurement system at the Oak Ridge National Laboratory (ORNL) for the U.S. Navy. Present tritium-in-air monitoring systems installed by the Navy can reliably measure to less than 10 muCi/m3, but medical and safety issues are pushing measurement needs to below 1 muCi/m3, which is equivalent to 1-10 nCi/ml in liquid samples, using calcium metal converter. A significant effort has been expended over the past 10 years by the Navy RADIAC Development Program at ORNL on various schemes to improve the detection of tritium in both air and liquid at near ambient levels. One such scheme includes a liquid flow-through system based on an NE102 sponge scintillator with dual photomultiplier tubes for tube noise rejection.
引用
收藏
页码:962 / 965
页数:4
相关论文
共 50 条
  • [1] PRESSURE MONITORING-SYSTEM FOR TRITIUM GAS TARGETS
    SEAGONDOLLAR, LW
    THAMBIDURAI, PM
    NUCLEAR INSTRUMENTS & METHODS, 1980, 173 (03): : 603 - 604
  • [2] A TRITIUM MONITORING-SYSTEM USING THE COHERENT DEMODULATION TECHNIQUE
    HORIUCHI, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 217 (03): : 479 - 482
  • [3] SYSTEM FOR PREPARATION OF STANDARD TRITIUM GAS SAMPLE FOR CALIBRATION OF MONITORING-SYSTEM
    HORIUTI, N
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1983, 25 (03): : 201 - 206
  • [4] DEVELOPMENT OF AN INTEGRATED MONITORING-SYSTEM FOR A NEW TRITIUM FACILITY AT MOUND
    RHINEHAMMER, TB
    BURGESS, TE
    SPYROU, EL
    FUSION TECHNOLOGY, 1985, 8 (02): : 2095 - 2102
  • [5] DEVELOPMENT OF AN INTEGRATED MONITORING-SYSTEM FOR A NEW TRITIUM FACILITY AT MOUND
    RHINEHAMMER, TB
    BURGESS, TE
    SPYROU, EL
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1985, 36 (07): : 577 - 577
  • [6] A TRITIUM MONITORING-SYSTEM USING A MODIFIED KANNE CHAMBER FOR USE IN TRITIUM CONTAMINATING ENVIRONMENTS
    ANDERSON, DF
    HIEBERT, RD
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1980, 31 (08): : 484 - 484
  • [7] CORROSION MONITORING-SYSTEM PROVIDES FAST MEASUREMENTS
    不详
    I&CS-INDUSTRIAL AND PROCESS CONTROL MAGAZINE, 1983, 56 (08): : 53 - 53
  • [8] TRITIUM MONITORING-SYSTEM FOR GB-10 GCFR FUEL IRRADIATION EXPERIMENT
    PRUITT, ME
    LONGEST, AW
    COSTANZO, DA
    CONLIN, JA
    GAT, U
    EPSTEIN, BD
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1976, 23 (JUN18): : 116 - 117
  • [9] ECM MONITORING-SYSTEM
    IMADA, AM
    OTTOBONI, EG
    MICROWAVE JOURNAL, 1984, 27 (11) : 139 - &
  • [10] THE INTELLIGENT MONITORING-SYSTEM
    BACHE, TC
    BRATT, SR
    WANG, J
    FUNG, RM
    KOBRYN, C
    GIVEN, JW
    BULLETIN OF THE SEISMOLOGICAL SOCIETY OF AMERICA, 1990, 80 (06) : 1833 - 1851