We have examined the potential usefulness in plasma lipid profiling of capillary columns coated with a high-temperature-polarizable phenylmethyl silicone liquid phase, previously employed for gas-liquid chromatography (GLC) of natural triacylglycerols. The column yielded an excellent resolution for plasma triacylglycerols. cholesteryl esters and the trimethylsilyl (TMS) and tert.-butyldimethylsilyl (t-BDMS) ethers of free cholesterol, as well as of the TMS and t-BDMS ethers of the diacylglycerols and ceramides released from plasma phospholipids by phospholipase C digestion. The various lipid classes were resolved into molecular species according to chain length and number of double bonds. The different molecular species were recovered in variable proportions as indicated by comparisons of peak area percentages obtained on the polar columns with those recorded on non-polar columns, which have been previously shown to give correct quantitative proportions. The cholesteryl esters are thermally degraded at high temperatures and must be eluted at as low a temperature as possible. Under the selected experimental conditions, the cholesteryl esters were found to partly interdigitate with the triacylglycerol species of carbon numbers 46-48. The TMS and t-BDMS ethers of diacylglycerols and ceramides emerged clearly ahead of the leading triacylglycerol of the 42 acyl carbon series. However, the diacylglycerol and ceramide species overlapped and interdigitated extensively with each other. Due to low polarity below 280°C, the polarizable-liquid phase was not suitable for the resolution of the molecular species of monoacylglycerols and free fatty acids, which were separated on the basis of carbon number only. Nevertheless, capillary GLC on the polarizable liquid phases provides a novel and informative profiling of plasma lipids, the application of which to the assay of plasma lipid abnormalities deserves further examination. © 1990.
引用
收藏
页码:427 / 441
页数:15
相关论文
共 50 条
  • [1] QUANTITATION OF PLASMA-LIPIDS BY GAS-LIQUID-CHROMATOGRAPHY ON HIGH-TEMPERATURE POLARIZABLE CAPILLARY COLUMNS
    KUKSIS, A
    MYHER, JJ
    GEHER, K
    JOURNAL OF LIPID RESEARCH, 1993, 34 (06) : 1029 - 1038
  • [2] NUTRITION IN RELATION TO GAS-LIQUID-CHROMATOGRAPHIC PROFILES OF PLASMA TOTAL LIPIDS
    KUKSIS, A
    MYHER, JJ
    GEHER, K
    BRECKENRIDGE, WC
    FEATHER, T
    MCGUIRE, V
    LITTLE, JA
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1984, 61 (04) : 677 - 678
  • [3] NANOGRAM TECHNIQUES .1. INJECTION WITHOUT LOSSES ON CAPILLARY GAS-LIQUID-CHROMATOGRAPHIC COLUMNS
    KLIMES, I
    STUNZI, W
    LAMPARSKY, D
    JOURNAL OF CHROMATOGRAPHY, 1977, 136 (01): : 13 - 21
  • [4] RELATIVE GAS-LIQUID-CHROMATOGRAPHIC RETENTION FACTORS OF TRIMETHYLSILYL ETHERS OF DIRADYLGLYCEROLS ON POLAR CAPILLARY COLUMNS
    MYHER, JJ
    KUKSIS, A
    JOURNAL OF CHROMATOGRAPHY, 1989, 471 : 187 - 204
  • [5] GAS-LIQUID-CHROMATOGRAPHIC ANALYSIS OF 2,4-DINITROPHENYLHYDRAZONES OF MONOCARBONYL COMPOUNDS IN CARROTS USING GLASS CAPILLARY COLUMNS
    LINKO, RR
    KALLIO, H
    RAINIO, K
    JOURNAL OF CHROMATOGRAPHY, 1978, 155 (01): : 191 - 194
  • [7] EVALUATION OF A GAS-LIQUID-CHROMATOGRAPHIC METHOD FOR DETERMINATION OF URINARY STEROIDS USING HIGH-RESOLUTION OPEN-TUBULAR GLASS CAPILLARY COLUMNS
    BAILEY, E
    FENOUGHTY, M
    JOURNAL OF CHROMATOGRAPHY, 1974, 96 (01): : 33 - 46
  • [8] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC AND GAS-LIQUID-CHROMATOGRAPHIC DETERMINATION OF DIAZEPAM AND NORDIAZEPAM IN PLASMA
    RAISYS, VA
    FRIEL, PN
    GRAAFF, PR
    OPHEIM, KE
    WILENSKY, AJ
    JOURNAL OF CHROMATOGRAPHY, 1980, 183 (04): : 441 - 448
  • [9] GAS-LIQUID-CHROMATOGRAPHIC ANALYSIS OF DIMEDONE DERIVATIVES OF FORMALDEHYDE AND OTHER ALIPHATIC-ALDEHYDES ON CAPILLARY COLUMNS
    JANOS, E
    BALLA, J
    TYIHAK, E
    GABORJANYI, R
    JOURNAL OF CHROMATOGRAPHY, 1980, 191 (APR): : 239 - 244
  • [10] A COMPARISON OF METHODS FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC AND CAPILLARY GAS-LIQUID-CHROMATOGRAPHIC ANALYSIS OF FATTY-ACID ESTERS
    BATY, JD
    WILLIS, RG
    TAVENDALE, R
    JOURNAL OF CHROMATOGRAPHY, 1986, 353 : 319 - 328