SIMULTANEOUS DOUBLE BALLOON CORONARY ANGIOPLASTY THROUGH A SINGLE GUIDING CATHETER FOR BIFURCATION LESIONS

被引:17
|
作者
THOMAS, ES
WILLIAMS, DO
机构
[1] RHODE ISL HOSP,DIV CARDIOL,DEPT MED,PROVIDENCE,RI 02902
[2] BROWN UNIV,PROGRAM MED,PROVIDENCE,RI 02912
来源
关键词
D O I
10.1002/ccd.1810150410
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:260 / 264
页数:5
相关论文
共 50 条
  • [1] CORONARY ANGIOPLASTY USING AN AUTOPERFUSION BALLOON CATHETER THROUGH A 6 FRENCH GUIDING CATHETER
    WOLFF, MR
    PREWITT, KC
    BRINKER, JA
    RESAR, JR
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 29 (03): : 247 - 250
  • [2] BALLOON ANGIOPLASTY OF CORONARY BIFURCATION LESIONS - THE KISSING BALLOON TECHNIQUE
    GEORGE, BS
    MYLER, RK
    STERTZER, SH
    CLARK, DA
    COTE, G
    SHAW, RE
    FISHMANROSEN, J
    MURPHY, M
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1986, 12 (02): : 124 - 138
  • [3] RETRIEVAL OF DIRECTIONAL CORONARY ATHERECTOMY GUIDING CATHETER WITH ANGIOPLASTY BALLOON CATHETER
    SABE, AAEG
    ETTINGER, SM
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1995, 35 (03): : 237 - 239
  • [4] CORONARY BIFURCATION STENOSES - THE KISSING BALLOON PROBE TECHNIQUE VIA A SINGLE GUIDING CATHETER
    MYLER, RK
    MCCONAHAY, DR
    STERTZER, SH
    JOHNSON, W
    CUMBERLAND, DC
    BOUCHER, RA
    HIDALGO, B
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1989, 16 (04): : 267 - 278
  • [5] CORONARY ANGIOPLASTY USING AN OVER-THE-WIRE BALLOON CATHETER THROUGH A NEW 6-FRENCH GUIDING CATHETER
    UENO, K
    KOTOO, Y
    ARAI, M
    MATSUBARA, T
    WATANABE, S
    ITO, H
    HIRAKAWA, S
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 26 (01): : 61 - 68
  • [6] BALLOON INFLATION CAUSED BY CONTRAST INJECTION THROUGH THE GUIDING CATHETER - AN UNUSUAL OBSERVATION DURING CORONARY ANGIOPLASTY
    VANGELDER, LM
    VANDERKRIEKEN, AM
    ELGAMAL, MIH
    BONNIER, JJRM
    MICHELS, HR
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1984, 10 (03): : 253 - 258
  • [7] CORONARY ANGIOPLASTY THROUGH A NEW 6 FRENCH GUIDING CATHETER
    RESAR, JR
    PREWITT, KC
    WOLFF, MR
    BRINKER, JA
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 32 (03): : 268 - 273
  • [8] KISSING BALLOON ANGIOPLASTY OF A CIRCUMFLEX ARTERY BIFURCATION LESION - A NEW APPROACH UTILIZING 2 BALLOON-ON-WIRE PROBES AND A SINGLE GUIDING CATHETER
    VANLEEUWEN, K
    BLANS, W
    PIJLS, NHJ
    VANDERWERF, T
    CHEST, 1989, 95 (05) : 1144 - 1145
  • [9] DOUBLE LOOP GUIDING CATHETER - A PRIMARY CATHETER FOR ANGIOPLASTY OF THE RIGHT CORONARY-ARTERY
    ARANI, DT
    BUNNELL, IL
    VISCO, JP
    CONLEY, JG
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1988, 15 (02): : 125 - 131
  • [10] BALLOON CATHETER CORONARY ANGIOPLASTY - BALLOON RUPTURE
    ANGELINI, P
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1990, 20 (02): : 150 - 151