INFLUENCE OF REACTOR GEOMETRY ON MIXING CHARACTERISTICS IN A DOWN FLOW JET LOOP BIOREACTOR - NEWTONIAN AND NON-NEWTONIAN FLUIDS

被引:0
|
作者
VELAN, M [1 ]
RAMANUJAM, TK [1 ]
机构
[1] ANNA UNIV,ALAGAPPA COLL TECHNOL,DEPT CHEM ENGN,MADRAS 600025,INDIA
来源
BIOPROCESS ENGINEERING | 1994年 / 11卷 / 03期
关键词
D O I
10.1007/BF00369605
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Mixing characteristics in the downcomer and the riser of a continuous down-flow jet loop bioreactor was studied with Newtonian and non-Newtonian fluids. The mixing parameters were determined through the curve fitting of the experimental impulse response data with the solution of one dimensional axial dispersion model. It was found that circulation number and axial dispersion coefficient increased with an increase in liquid flow rate and draft tube to column diameter ratio and the axial dispersion coefficient was comparatively higher in the riser. The circulation number increased with decrease in nozzle diameter. The model predicted the experimental data well within 8% deviation for both the systems (water and CMC). Correlations were obtained to predict axial dispersion coefficients in the riser and downcomer of the reactor.