Blood patch for the treatment of post-dural puncture tinnitus

被引:2
|
作者
Jia, Wei [1 ]
Fadhlillah, Fiqry [2 ]
机构
[1] London North West Healthcare NHS Trust, Ear Nose & Throat ENT Dept, London, England
[2] Chelsea & Westminster Hosp NHS Fdn Trust, Emergency Dept, London, England
来源
关键词
Otolaryngology; lumbar puncture; tinnitus;
D O I
10.1177/2050313X18759445
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Audiometric disturbances are recognised as potential complications after spinal or epidural anaesthesia; however, incidences of tinnitus occur less frequently. We report a case of a patient with severe bilateral tinnitus post-lumbar puncture who was treated with an epidural blood patch. A 40-year-old ASA I lady (a medically fit patient with no known medical problem) presented with ongoing bilateral severe tinnitus for 6 days after a lumbar puncture. Venous blood (18 mL) was injected into the epidural space using a 16G needle. The patient completed the Tinnitus Handicap Inventory Questionnaire before the blood patch, 3 h, 24 h and 1-month post-procedure. An audiogram was also conducted before and 1 month after the blood patch. The patient scored 84 (grade 5) on the Tinnitus Handicap Inventory before the blood patch. Three hours post-procedure, her score improved to 16 (grade 1), with complete resolution by 24 h. Audiogram revealed a low-frequency mild sensorineural hearing loss in the left ear prior to the procedure. By her 1-month follow-up, her hearing loss was back to normal. In our experience, an epidural blood patch is an effective treatment for post-dural puncture tinnitus. Its effects are instantaneous and complete resolution is achieved by 24 h.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Transforaminal cervical blood patch for the treatment of post-dural puncture headache
    Slipman, CW
    El Abd, OH
    Bhargava, A
    DePalma, MJ
    Chin, KR
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2005, 84 (01) : 76 - 80
  • [2] Epidural blood patch with allogeneic blood for post-dural puncture headache
    Cesur, M
    Alici, HA
    Erdem, AF
    Yüksek, MS
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2005, 14 (03) : 261 - 262
  • [3] Epidural blood patch with allogeneic blood for post-dural puncture headache
    Turner, Marc
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2006, 15 (03) : 261 - 261
  • [4] From Post-Dural Puncture Headache to Blood Patch - a case report
    Gomes, Leonor
    Valente, Elisabete
    Muendane, Paulo
    Goncalves, Lucia
    Laranjo, Marta
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 1703 - 1703
  • [5] Effectiveness of epidural blood patch in the management of post-dural puncture headache
    Safa-Tisseront, V
    Thormann, F
    Malassiné, P
    Henry, M
    Riou, B
    Coriat, P
    Seebacher, J
    ANESTHESIOLOGY, 2001, 95 (02) : 334 - 339
  • [6] Recurrence of Post-dural Puncture Headache After a Successful Blood Patch
    Barbosa, Joao
    Valentim, Maria
    Almeida, Mariana
    Carneiro, Sara
    Vasconcelos, Lucia
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (11)
  • [8] Successful treatment of a recurrent post-dural puncture headache with an epidural blood patch 18 months after the initial dural puncture
    Spring, A.
    McMorrow, R.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2019, 40 : 152 - 153
  • [9] Treatment of obstetric post-dural puncture headache. Part 2: epidural blood patch
    Russell, R.
    Laxton, C.
    Lucas, D. N.
    Niewiarowski, J.
    Scrutton, M.
    Stocks, G.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2019, 38 : 104 - 118
  • [10] Seven months' delay for epidural blood patch in post-dural puncture headache
    Ferre, JP
    Gentili, ME
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1999, 16 (04) : 257 - 258