IDENTIFICATION OF 3-ELEMENT WINDKESSEL MODEL - COMPARISON OF TIME AND FREQUENCY-DOMAIN TECHNIQUES

被引:5
|
作者
POCHET, T
GERARD, P
MARNETTE, JM
DORIO, V
MARCELLE, R
FATEMI, M
FOSSION, A
JUCHMES, J
机构
[1] STATE UNIV LIEGE,INST MATH,B-4000 LIEGE,BELGIUM
[2] STATE UNIV LIEGE,INST CHIRURG CARDIOVASC,B-4000 LIEGE,BELGIUM
[3] STATE UNIV LIEGE,INST MED INTERNE,B-4000 LIEGE,BELGIUM
[4] STATE UNIV LIEGE,INST PHYSIOL HUMAINE,B-4000 LIEGE,BELGIUM
关键词
WINDKESSEL MODEL; 3-ELEMENT MODEL; DOG;
D O I
10.3109/13813459208998118
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The problem of the parameter identification of the three-element windkessel model is studied. Minimization by least-square technique - LSQ - in time domain and frequential techniques - FFT - are compared. Continuous pressure and flow curves were recorded in the proximal aorta of an open chest dog. Comparison shows very high correlations between the parameter estimations obtained by LSQ and FFT methods. However, systematic differences appear between the calculated values, but do not seem to endanger physiological interpretation of the results.
引用
收藏
页码:295 / 301
页数:7
相关论文
共 50 条
  • [1] IDENTIFICATION OF THE 3-ELEMENT WINDKESSEL MODEL INCORPORATING A PRESSURE-DEPENDENT COMPLIANCE
    CAPPELLO, A
    GNUDI, G
    LAMBERTI, C
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1995, 23 (02) : 164 - 177
  • [2] COMPARISON OF TIME-DOMAIN AND FREQUENCY-DOMAIN MEASUREMENT TECHNIQUES IN ANTENNA THEORY
    YOUNG, JD
    SVOBODA, DE
    BURNSIDE, WD
    [J]. IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1973, AP21 (04) : 581 - 583
  • [3] A comparison of time- and frequency-domain wireless channel sounding techniques
    Flikkema, PG
    Johnson, SG
    [J]. PROCEEDINGS OF THE IEEE SOUTHEASTCON '96: BRINGING TOGETHER EDUCATION, SCIENCE AND TECHNOLOGY, 1996, : 488 - 491
  • [4] MODEL IDENTIFICATION AND REDUCTION IN THE FREQUENCY-DOMAIN
    KARPE, PA
    MADHAVAN, KP
    CHIDAMBARAM, M
    [J]. INTERNATIONAL JOURNAL OF CONTROL, 1987, 45 (02) : 421 - 438
  • [5] The reservoir pressure concept: the 3-element windkessel model revisited? Application to the Asklepios population study
    Vermeersch, S. J.
    Rietzschel, E. R.
    De Buyzere, M. L.
    Van Bortel, L. M.
    Gillebert, T. C.
    Verdonck, P. R.
    Segers, P.
    [J]. JOURNAL OF ENGINEERING MATHEMATICS, 2009, 64 (04) : 417 - 428
  • [6] A unified approach for time-domain and frequency-domain finite element model updating
    Li, Dan
    Zhou, Jiajun
    He, Xinhao
    [J]. Mechanical Systems and Signal Processing, 227
  • [7] PULMONARY ARTERIAL DYNAMICS AT REST AND EXERCISE IN NORMAL MAN - APPLICATION OF THE 3-ELEMENT WINDKESSEL MODEL
    SLIFE, DM
    LATHAM, RD
    [J]. CLINICAL RESEARCH, 1989, 37 (02): : A297 - A297
  • [8] The reservoir pressure concept: the 3-element windkessel model revisited? Application to the Asklepios population study
    S. J. Vermeersch
    E. R. Rietzschel
    M. L. De Buyzere
    L. M. Van Bortel
    T. C. Gillebert
    P. R. Verdonck
    P. Segers
    [J]. Journal of Engineering Mathematics, 2009, 64 : 417 - 428
  • [9] Intermolecular spectral densities of liquids: A quantitative comparison of time-domain and frequency-domain techniques
    Cong, P
    Simon, JD
    She, CY
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1996, 104 (03): : 962 - 966
  • [10] Performance Comparison of Time-Domain and Frequency-Domain Beamforming Techniques for Sensor Array Processing
    Hamid, Umar
    Qamar, Rahim Ali
    Waqas, Kashif
    [J]. PROCEEDINGS OF 2014 11TH INTERNATIONAL BHURBAN CONFERENCE ON APPLIED SCIENCES & TECHNOLOGY (IBCAST), 2014, : 379 - 385