DETECTION OF FIBRIN D-DIMER IN PLASMA AND URINE OF PREGNANT-WOMEN USING DIMERTEST LATEX ASSAY

被引:8
|
作者
TROFATTER, KF
TROFATTER, MO
CAUDLE, MR
OFFUTT, DQ
机构
[1] Department of Obstetrics and Gynecology, University of Tennessee Graduate Medical School, Knoxville, TN
关键词
D O I
10.1097/00007611-199309000-00009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Eighty-six women admitted for evaluation of preeclampsia had plasma and urine screened for the presence of fibrin D-dimer using the monoclonal antibody DD-3B6 in a latex fixation assay (Dimertest). In 53 of the women screened, results were negative for fibrin D-dimer in both plasma and urine; in 33, results were positive in urine (N = 11), plasma (N = 14), or both (N = 8). D-dimer positive women were at increased risk for earlier delivery (mean 34 versus 36 weeks), lower birth weight babies (mean 2,327 versus 2,669 g), higher mean arterial pressures (mean 104 versus 94mm Hg), liver function test abnormalities (mean lactate dehydrogenase value 256 versus 142 U/L, mean serum glutamic-oxaloacetic transaminase 67 versus 23 U/L), and significantly elevated levels (>40 mug/mL) of fibrin(ogen) degradation products (FDPs). Interestingly, 22 of 33 D-dimer positive women had insignificant levels of FDPs. Generally, D-dimer negative women had no significant abnormalities in results of coagulation tests and liver function tests. This study confirms previous observations on the value of D-dimer detection in screening for preeclampsia coagulopathy and extends this tool to its detection in urine.
引用
收藏
页码:1017 / 1021
页数:5
相关论文
共 50 条
  • [1] A FAST, QUANTITATIVE PLASMA D-DIMER LATEX BASED ASSAY
    BRANDJES, DPM
    MORRIEN, WM
    LEVELS, HHM
    VANDENENDE, A
    BULLER, HR
    VANBEEK, EJR
    TENCATE, JW
    THROMBOSIS AND HAEMOSTASIS, 1995, 73 (06) : 1140 - 1140
  • [2] Evaluation of the STA liatest D-Di and AGEN dimertest latex in the detection of d-dimer in disseminated intravascular coagulation
    Pham, Tina
    Collecut, Margaret
    Opat, Stephen
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2007, 29 : 75 - 75
  • [3] ASSAY OF ESTROGENS IN URINE FRACTIONS OF PREGNANT-WOMEN
    CHEVARY, S
    CHABA, I
    LABORATORNOE DELO, 1983, (05): : 17 - 20
  • [4] Comparison of three D-dimer latex assays and a turbiquant D-dimer assay with FDP levels
    AlOmar, H
    Storbeck, M
    Garvey, B
    Freedman, J
    THROMBOSIS AND HAEMOSTASIS, 1997, : P1786 - P1786
  • [5] Plasma D-dimer and urine D-dimer are associated with resectability of pancreatic cancer
    Bahrun, Mulkyawan
    Labeda, Ibrahim
    Mappincara, Mappincara
    Hendarto, Joko
    Lusikooy, Ronald E.
    Warsinggih, Warsinggih
    Sampetoding, Samuel
    Kusuma, Muhammad I.
    Uwuratuw, Julianus A.
    Syarifuddin, Erwin
    Faruk, Muhammad
    CHIRURGIA, 2023, 36 (06) : 324 - 328
  • [6] The reference ranges of D-dimer levels are different in pregnant women using various D-dimer assays
    Kessler, P.
    Petrik, R.
    Poul, H.
    Kusnierova, M.
    Horkay, G.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 592 - 592
  • [7] Plasma D-dimer and urine D-dimer are associated with resectability of pancreatic cancer
    Bahrun, Mulkyawan
    Labeda, Ibrahim
    Mappincara, Mappincara
    Hendarto, Joko
    Lusikooy, Ronald E.
    Warsinggih, Warsinggih
    Sampetoding, Samuel
    Kusuma, Muhammad I.
    Uwuratuw, Julianus A.
    Syarifuddin, Erwin
    Faruk, Muhammad
    CHIRURGIA-ITALY, 2023, 36 (06): : 324 - 328
  • [8] Latex Agglutination D-Dimer Assay Compared to an ELISA Based D-Dimer Assay in the Exclusion of Acute Pulmonary Embolism
    Cotter, O. T.
    O'Neill, S. B.
    Crinion, S. J.
    Kennedy, B.
    Curran, D. R.
    O'Connor, T. M.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2011, 180 : S472 - S472
  • [9] Reference interval of D-dimer in pregnant women
    Giavarina, D
    Mezzena, G
    Dorizzi, RM
    Soffiati, G
    CLINICAL BIOCHEMISTRY, 2001, 34 (04) : 331 - 333
  • [10] VALUE AND LIMITATIONS OF THE ASSAY OF A FIBRIN DEGRADATION PRODUCT - D-DIMER
    LEVY, G
    SEMAINE DES HOPITAUX, 1987, 63 (25): : 2061 - 2064