摘要
Conventional tomography has been criticized for its low contrast caused by scattered radiation and tomographic blur. The authors developed a digital tomosynthesis system as a substitute for conventional tomography. With the image processor in the system, two types of postprocessing can be performed to improve the quality of synthesized tomograms. One-dimensional spatial frequency filtering effectively reduces linear tomographic blur and enhances image information when an appropriate filter is used. Correction of structure mottle helps enhance the image clarity. The system allows reconstruction of tomograms at any desired depth and performance of tomosynthetic angiography and dual-energy subtraction. The system solves some of the problems associated with plain tomography and dual-energy subtraction and provides diagnostic clinical images.
引用
收藏
页码:807 / 822
页数:16
相关论文
共 50 条
  • [1] CLINICAL-APPLICATION OF DIGITAL TOMOSYNTHESIS
    MARAVILLA, KR
    MURRY, RC
    HORNER, S
    DIEHL, JT
    BAZAN, C
    RADIOLOGY, 1982, 144 (04) : 961 - 961
  • [2] CLINICAL-APPLICATION OF HIGH-RESOLUTION CYTOGENETICS
    MONSALVE, MV
    REVISTA BRASILEIRA DE GENETICA, 1985, 8 (01): : 157 - 165
  • [3] CLINICAL-APPLICATION OF HIGH-RESOLUTION DIGITAL IMAGE STORAGE FOR GENERAL RADIOGRAPHY
    EDMONDS, EW
    HYNES, DM
    ROWLANDS, JA
    TOTH, BD
    PORTER, AJ
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 535 : 386 - 393
  • [4] CLINICAL-APPLICATION OF DIGITAL TOMOSYNTHESIS - A PRELIMINARY-REPORT
    MARAVILLA, KR
    MURRY, RC
    DECK, M
    HORNER, S
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1983, 4 (03) : 277 - 280
  • [5] HIGH-RESOLUTION AND INEXPENSIVE BODY-SURFACE POTENTIAL MAPPING SYSTEM FOR CLINICAL-APPLICATION
    JIN, J
    SCHOFFA, G
    BIOMEDIZINISCHE TECHNIK, 1988, 33 (1-2): : 10 - 17
  • [6] DENSITOMETRIC SCANNING OF HIGH-RESOLUTION ELECTROPHORESIS OF SERUM - METHODOLOGY AND CLINICAL-APPLICATION
    KEREN, DF
    DISANTE, AC
    BORDINE, SL
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1986, 85 (03) : 348 - 352
  • [7] CLINICAL-APPLICATION OF THE HIGH-RESOLUTION FREQUENCY ANALYZER - 1ST RESULTS
    REMACLE, M
    MILLET, B
    VANHEULE, P
    DUVIVIER, D
    FOLIA PHONIATRICA, 1989, 41 (06): : 259 - 269
  • [8] HIGH-RESOLUTION MNR OF THE INNER MEDIUM - FROM TECHNICAL EVALUATION TO CLINICAL-APPLICATION
    VIONDURY, J
    NICOLI, F
    KRIAT, M
    SCIAKY, M
    MOULYBANDINI, A
    BRUNET, P
    SILVESTRE, P
    VIOUT, P
    CONFORTGOUNY, S
    COZZONE, PJ
    JOURNAL DE MEDECINE NUCLEAIRE ET BIOPHYSIQUE, 1992, 16 (04): : 389 - 400
  • [9] INVESTIGATIONS INTO THE IMZ SYSTEM AND ITS CLINICAL-APPLICATION
    WEBER, H
    BRITISH DENTAL JOURNAL, 1989, 167 (11) : 408 - 408
  • [10] DEVELOPMENT AND CLINICAL-APPLICATION OF THE ESSEN AFTERLOADING SYSTEM
    BUSCH, M
    ALBERTI, W
    TUMORDIAGNOSTIK & THERAPIE, 1986, 7 : 50 - 54