A calorimeter suitable for measuring human energy expenditure has been assembled by the US Department of Agriculture in Beltsville, Maryland. The room-sized calorimeter is 3.05 x 2.74 x 2.44 m (20.39 m3). Direct and indirect calorimetry methods are used to simultaneously measure heat emission and energy expenditure. A water-cooled gradient layer chamber is used to measure human heat production directly. Indirect calorimetry is ascertained by measuring the changes in gas composition of the air entering and exiting the chamber. The inlet and outlet air are each sampled three times every 100 s with a multiple gas analyzer to determine carbon dioxide and methane production and oxygen consumption within the chamber. A total of 30 measurements, which include temperature, pressure, gas fractions, flow rates, direct heat transfer, electrical power, and motion within the chamber, are converted from electrical to digital signals and recorded on magnetic disk nine times each minute. Real-time calculations for directly and indirectly measured energy expenditure are continuously updated and displayed. The performance of the calorimeter is assessed by the combustion of alcohol within the chamber. Results of these tests indicate that the direct heat recovery is 99.7 +/- 2.6 (SD) % and the indirect heat recovery is 100.3 +/- 1.3 (SD) %.
引用
收藏
页码:E306 / E320
页数:15
相关论文
共 50 条
  • [1] A room-sized respirator
    Drinker, P
    Wilson, JL
    NEW ENGLAND JOURNAL OF MEDICINE, 1933, 209 : 227 - 230
  • [2] Relationship between overnight energy expenditure and BMR measured in a room-sized calorimeter
    JL Seale
    JM Conway
    European Journal of Clinical Nutrition, 1999, 53 : 107 - 111
  • [3] Relationship between overnight energy expenditure and BMR measured in a room-sized calorimeter
    Seale, JL
    Conway, JM
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1999, 53 (02) : 107 - 111
  • [4] Room-sized Informal Telepresence System
    Dou, Mingsong
    Shi, Ying
    Frahm, Jan-Michael
    Fuchs, Henry
    Mauchly, Bill
    Marathe, Mod
    IEEE VIRTUAL REALITY CONFERENCE 2012 PROCEEDINGS, 2012, : 15 - 18
  • [5] DIRECT-INDIRECT DISTINCTION IN MORALS
    DIIANNI, AR
    THOMIST, 1977, 41 (03): : 350 - 380
  • [6] Reforming the direct-indirect tax mix
    Smart, M
    INTERNATIONAL TAX AND PUBLIC FINANCE, 2002, 9 (02) : 143 - 155
  • [7] Vibration of a room-sized airspring-supported slab
    Amick, H
    Sennewald, B
    Pardue, NC
    Teague, C
    Scace, B
    NOISE CONTROL ENGINEERING JOURNAL, 1998, 46 (02) : 39 - 47
  • [8] INDIRECT AND COMBINED DIRECT-INDIRECT THERAPY IN A DYSFLUENT CHILD
    RAMIG, PR
    WALLACE, ML
    JOURNAL OF FLUENCY DISORDERS, 1987, 12 (01) : 41 - 49
  • [9] Protopiper: Physically Sketching Room-Sized Objects at Actual Scale
    Agrawal, Harshit
    Umapathi, Udayan
    Kovacs, Robert
    Johannes, Frohnhofen
    Chen, Hsiang-Ting
    Mueller, Stefanie
    Baudisch, Patrick
    UIST'15: PROCEEDINGS OF THE 28TH ANNUAL ACM SYMPOSIUM ON USER INTERFACE SOFTWARE AND TECHNOLOGY, 2015, : 427 - 436
  • [10] Mental representation of spatial structure in a virtual room-sized space
    Luo, Zhiqiang
    Duh, Henry Been-Lirn
    ADVANCES IN ARTIFICIAL REALITY AND TELE-EXISTENCE, PROCEEDINGS, 2006, 4282 : 1166 - +