摘要
Continuous measurement of arterial blood density after bolus injection of fluids of different density into the right atrium has been used to measure cardiac output and mean transit time through the central circulation. The transit time distribution for density, however, differs from that for plasma-phase tracers such as indocyanine green. This difference may yield important information about red cell transit times through the microcirculation. We analyzed the potential of the density technique to resolve small changes in transit time distributions. Rayleigh's Method was used to calculate the relationship between density distribution within the U-tube and frequency of oscillation. Fourier integral transformation of a functional representation of indocyanine green dye curves provided an estimate of amplitude versus frequency for likely input density signals. We found that the ability of the densitometer to accurately follow blood density changes depends upon physiologic parameters associated with the experimental animal and upon the physical characteristics of the densitometer itself. Even for small animals, such as a rabbit, the densitometer theoretically has the ability to accurately follow rapid density changes over time.
引用
收藏
页码:361 / 365
页数:5
相关论文
共 50 条
  • [1] DENSITY-MEASUREMENT ACCURACY AND ITS INFLUENCE ON DETERMINATION OF NONISOTHERMAL DENSIFICATION KINETICS
    HARE, TM
    AMERICAN CERAMIC SOCIETY BULLETIN, 1977, 56 (03): : 290 - 290
  • [2] CONTINUOUS VOLUME AND DENSITY-MEASUREMENT OF STARCH SUSPENSIONS
    KEMPF, W
    FRIEDRICH, I
    HOEPKE, CH
    VELDKAMP, J
    VIERHUF, J
    BRADTMOLLER, W
    STARKE, 1976, 28 (02): : 54 - 68
  • [3] COMPARISON BETWEEN HEMATOCRIT AND BLOOD DENSITY-MEASUREMENT
    HINGHOFERSZALKAY, H
    KENNER, T
    LEOPOLD, H
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1978, 377 : R22 - R22
  • [4] CONTINUOUS DENSITY-MEASUREMENT OF ATOMIC-HYDROGEN BY MEANS OF A BOLOMETER
    MERTIG, M
    LUPPOV, VG
    ROSER, T
    VUARIDEL, B
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (01): : 251 - 252
  • [5] DETERMINATION OF THE PARTIAL SPECIFIC VOLUME OF DISSOLVED POLYMERS BY CONTINUOUS DENSITY-MEASUREMENT
    LINOW, KJ
    OKATOVA, O
    PHILIPP, B
    ACTA POLYMERICA, 1983, 34 (06) : 376 - 377
  • [6] ACCURACY OF MEASURED AND PREDICTED RESIDUAL LUNG-VOLUME ON BODY DENSITY-MEASUREMENT
    MORROW, JR
    JACKSON, AS
    BRADLEY, PW
    HARTUNG, GH
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1986, 18 (06): : 647 - 652
  • [7] SCATTER AND DENSITY-MEASUREMENT IN ONLINE X-RAY ANALYSIS
    SMITH, HW
    CIM BULLETIN, 1977, 70 (788): : 101 - 102
  • [8] ANALYSIS OF SURFACE FINISH IN MILLING BY POWER SPECTRAL DENSITY-MEASUREMENT
    BOHOSIEVICI, C
    PRECISION ENGINEERING-JOURNAL OF THE AMERICAN SOCIETY FOR PRECISION ENGINEERING, 1986, 8 (01): : 24 - 26
  • [9] Accuracy of cardiac output monitoring by continuous pulse contour analysis in hemodynamic instable patients
    Godje, O
    Friedl, R
    Hannekum, A
    CRITICAL CARE MEDICINE, 2001, 29 (12) : A118 - A118
  • [10] Continuous and less invasive central hemodynamic monitoring by blood pressure waveform analysis
    Mukkamala, Ramakrishna
    Xu, Da
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2010, 299 (03): : H584 - H599