FLOW-INJECTION AMPEROMETRY OF CYSTEINE AND GLUTATHIONE AT AN ELECTRODE MODIFIED WITH A RUTHENIUM-CONTAINING INORGANIC FILM

被引:55
|
作者
COX, JA
GRAY, TJ
机构
[1] Department of Chemistry, Miami University, Oxford, Ohio
关键词
D O I
10.1002/elan.1140020205
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A film that contains ruthenium oxide of mixed valences and cyanide (mvRuCN) on a glassy carbon electrode promotes the diffusion‐controlled oxidation of cysteine and glutathione at 0.92 V vs. Ag/AgCl. These mediated oxidations allow the determination of these thiols by flow‐injection amperometry in pH 2 solutions of 0.2 or 0.02 M K2SO4. Calibration curves are linear over about three orders of magnitude, and detection limits are in the submicromolar range with 7.5 μL injections. The sensitivity for cysteine is about 50 nA/μM with a flow rate of 1.0 mL/min. The throughput calculated on the basis of peak widths was 140 samples/h. Experimentally, with a manual injector, 60 samples/h were routinely analyzed. The sensitivity for glutathione in 0.2 M K2SO4 at pH 2 is somewhat lower, 36 nA/μM. A single electrode was used for hundreds of injections over a 2‐week period with no change in sensitivity. The mvRuCN‐coated electrode is operated in a potentiostatic mode; reactivation of the surface between series of experiments was not necessary. The electrode was stored at open circuit in contact with an electrolyte solution when not in use. Copyright © 1990 VCH Publishers, Inc.
引用
收藏
页码:107 / 111
页数:5
相关论文
共 50 条
  • [1] AMPEROMETRY OF THIOLS IN A FLOW-INJECTION SYSTEM WITH A NICKEL-OXIDE ELECTRODE
    ARIKAWA, Y
    HUBER, CO
    ANALYTICA CHIMICA ACTA, 1990, 229 (02) : 191 - 195
  • [2] Selective Voltammetric and Flow-Injection Determination of Guanosine and Adenosine at a Glassy Carbon Electrode Modified with a Ruthenium Hexachlororuthenate Film
    L. G. Shaidarova
    A. V. Gedmina
    V. D. Demina
    I. A. Chelnokova
    H. C. Budnikov
    Journal of Analytical Chemistry, 2018, 73 : 390 - 398
  • [3] Selective Voltammetric and Flow-Injection Determination of Guanosine and Adenosine at a Glassy Carbon Electrode Modified with a Ruthenium Hexachlororuthenate Film
    Shaidarova, L. G.
    Gedmina, A. V.
    Demina, V. D.
    Chelnokova, I. A.
    Budnikov, H. C.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 73 (04) : 390 - 398
  • [5] Selective voltammetric and flow-injection determination of guanine and adenine on a glassy carbon electrode modified by a ruthenium hexachloroplatinate film
    Shaidarova, L. G.
    Gedmina, A. V.
    Zhaldak, E. R.
    Chelnokova, I. A.
    Budnikov, G. K.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 69 (08) : 741 - 749
  • [6] Selective voltammetric and flow-injection determination of guanine and adenine on a glassy carbon electrode modified by a ruthenium hexachloroplatinate film
    L. G. Shaidarova
    A. V. Gedmina
    E. R. Zhaldak
    I. A. Chelnokova
    G. K. Budnikov
    Journal of Analytical Chemistry, 2014, 69 : 741 - 749
  • [7] STABLE MODIFIED ELECTRODES FOR FLOW-INJECTION AMPEROMETRY - APPLICATION TO THE DETERMINATION OF THIOCYANATE
    COX, JA
    GRAY, T
    KULKARNI, KR
    ANALYTICAL CHEMISTRY, 1988, 60 (17) : 1710 - 1713
  • [8] Nickel-chromium electrode as a detector in flow-injection amperometry: Determination of glycerol
    de Mattos, IL
    Melo, D
    Zagatto, EAG
    ANALYTICAL SCIENCES, 1999, 15 (06) : 537 - 541
  • [9] Nickel-Chromium Electrode as a Detector in Flow-Injection Amperometry: Determination of Glycerol
    Ivanildo Luiz de Mattos
    Denise Melo
    Elias Ayres Guidetti Zagatto
    Analytical Sciences, 1999, 15 : 537 - 541
  • [10] Flow-injection and sequential injection determination of hydroxypurines on an electrode modified with mixed-valence ruthenium and iridium oxides
    L. G. Shaidarova
    I. A. Chelnokova
    G. F. Makhmutova
    M. A. Degteva
    A. V. Gedmina
    H. C. Budnikov
    Journal of Analytical Chemistry, 2014, 69 : 864 - 874