Operation and performance of the CMS Electromagnetic Calorimeter during the 2010 run

被引:0
|
作者
Di Matteo, L. [1 ,2 ]
机构
[1] Univ Milano Bicocca, Milan, Italy
[2] INFN, Sezione Milano, Milan, Italy
关键词
D O I
10.1393/ncc/i2011-11071-0
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The CMS Electromagnetic Calorimeter (ECAL) is a high resolution, finely grained calorimeter devised to measure photons and electrons at LHC. Built of lead tungstate crystals, it plays a crucial role in the search for new physics as well as in precision measurements in the Standard Model. The status and general performance of the CMS ECAL in proton-proton collisions 2010 run at root s = 7TeV are described. The precision of the inter-channel calibration and absolute energy scale has been verified and improved exploiting in situ data. The quality of the offline data reconstruction, from low level quantities to high level objects, has been investigated and improved using known physics processes. Collision data and data/MC comparisons have been used to measure and tune the detector performance.
引用
收藏
页码:300 / 302
页数:3
相关论文
共 50 条
  • [1] Performance of the CMS electromagnetic calorimeter during the LHC Run II
    Zghiche, Amina
    18TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN PARTICLE PHYSICS (CALOR2018), 2019, 1162
  • [2] CMS Electromagnetic Calorimeter performance during the 2011 LHC run
    Montanino, D.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2013, 36 (01): : 269 - 270
  • [3] Performance and operation of the CMS electromagnetic calorimeter
    Chatrchyan, S.
    Khachatryan, V.
    Sirunyan, A. M.
    Adam, W.
    Arnold, B.
    Bergauer, H.
    Bergauer, T.
    Dragicevic, M.
    Eichberger, M.
    Eroe, J.
    Friedl, M.
    Fruehwirth, R.
    Ghete, V. M.
    Hammer, J.
    Haensel, S.
    Hoch, M.
    Hoermann, N.
    Hrubec, J.
    Jeitler, M.
    Kasieczka, G.
    Kastner, K.
    Krammer, M.
    Liko, D.
    de Abril, I. Magrans
    Mikulec, I.
    Mittermayr, F.
    Neuherz, B.
    Oberegger, M.
    Padrta, M.
    Pernicka, M.
    Rohringer, H.
    Schmid, S.
    Schoefbeck, R.
    Schreiner, T.
    Stark, R.
    Steininger, H.
    Strauss, J.
    Taurok, A.
    Teischinger, F.
    Themel, T.
    Uhl, D.
    Wagner, P.
    Waltenberger, W.
    Walzel, G.
    Widl, E.
    Wulz, C. -E.
    Chekhovsky, V.
    Dvornikov, O.
    Emeliantchik, I.
    Litomin, A.
    JOURNAL OF INSTRUMENTATION, 2010, 5
  • [4] Performance of the CMS electromagnetic calorimeter in the LHC Run II
    Bartosik, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 936 : 139 - 140
  • [5] Commissioning and Operation of the CMS Electromagnetic Calorimeter
    Petyt, David A.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2254 - 2259
  • [6] Calibration and Performance of the CMS Electromagnetic Calorimeter in LHC Run2
    Cavallari, Francesca
    Rovelli, Chiara
    24TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2019), 2020, 245
  • [7] Calibration and performance of the CMS Electromagnetic Calorimeter in LHC Run-II
    Kuo, C. M.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (06):
  • [8] PERFORMANCE OF THE CMS ELECTROMAGNETIC CALORIMETER
    Pastrone, N.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 354 - 358
  • [9] The CMS electromagnetic calorimeter calibration during Run I: progress achieved and expectations for Run II
    Ghezzi, Alessio
    16TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2014), 2015, 587
  • [10] Performance of the CMS Electromagnetic Calorimeter at the LHC
    Della Ricca, Giuseppe