ON LINE DETERMINATION OF PERPHENAZINE USING FLOW-INJECTION ANALYSIS

被引:7
|
作者
SULTAN, SM
ABDENNABI, AM
机构
[1] King Fahd Univ, Dept Chem, Dhahran, 31261
关键词
D O I
10.1006/mchj.1993.1107
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An accurate specific flow injection spectrophotometric method for the determination of perphenazine in the range 50-250 ppm is introduced. In the method, 110 μl of the drug is injected through a stream of 0.2% (w/v) potassium dichromate in 0.25 M sulfuric acid flowing on line as a carrier stream. The drug is oxidized on the flow to the red monocation radical, the peak absorbance of which is monitored at 525 nm. A throughput of up to 300 samples per hour is attained. The mechanism of the reaction is suggested and the method is compared with the United States Pharmacopeia method. © 1993 Academic Press. All rights reserved.
引用
收藏
页码:343 / 348
页数:6
相关论文
共 50 条
  • [1] The determination of perphenazine by a new simple flow-injection chemiluminescence method
    Han, XN
    Tang, YH
    Yu, CL
    Zheng, XH
    Jin, QJ
    [J]. ANALYTICAL LETTERS, 2005, 38 (12) : 1933 - 1941
  • [2] Multicomponent determination of drugs using flow-injection analysis
    Hlabangana, Leah
    Hernandez-Cassou, Santiago
    Saurina, Javier
    [J]. CURRENT PHARMACEUTICAL ANALYSIS, 2006, 2 (02) : 127 - 140
  • [3] TURBIDIMETRIC DETERMINATION OF CHLORHEXIDINE USING FLOW-INJECTION ANALYSIS
    CALATAYUD, JM
    FALCO, PC
    SAMPEDRO, AS
    [J]. ANALYST, 1987, 112 (01) : 87 - 90
  • [4] DETERMINATION OF CHLORHEXIDINE BY FLOW-INJECTION ANALYSIS
    LAU, KK
    [J]. FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 332 (04): : 370 - 371
  • [5] DETERMINATION OF CLONAZEPAM BY FLOW-INJECTION ANALYSIS
    LATORRE, C
    BLANCO, MH
    ABAD, EL
    VICENTE, J
    HERNANDEZ, L
    [J]. ANALYST, 1988, 113 (02) : 317 - 319
  • [6] Determination of molybdenum by flow-injection analysis
    Barakat, SA
    Mahmoud, TY
    [J]. ACTA CHIMICA SLOVENICA, 2003, 50 (04) : 799 - 806
  • [7] DEVELOPMENT OF A SPECTROPHOTOMETRIC DETERMINATION OF SIDEROPHORES USING FLOW-INJECTION ANALYSIS
    TRSKOVA, R
    RYCHLOVSKY, P
    NEMCOVA, I
    JEGOROV, A
    [J]. TALANTA, 1995, 42 (06) : 837 - 843
  • [8] DETERMINATION OF MITOXANTRONE BY FLOW-INJECTION ANALYSIS USING AN AMPEROMETRIC DETECTOR
    VILLAR, JCC
    GARCIA, AC
    BLANCO, PT
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1992, 10 (04) : 263 - 267
  • [9] AUTOMATED FLUORIMETRIC DETERMINATION OF CREATINE USING FLOW-INJECTION ANALYSIS
    MASOOM, M
    [J]. JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 1989, 11 (01): : 32 - 36
  • [10] DETERMINATION OF ISOPRENALINE WITH LUCIGENIN CHEMILUMINESCENCE USING FLOW-INJECTION ANALYSIS
    ALWARTHAN, AA
    ALTAMRAH, SA
    ALAKEL, AA
    [J]. ANALYTICAL SCIENCES, 1994, 10 (03) : 449 - 452