HOMOGENEOUS AMPEROMETRIC IMMUNOASSAY FOR THEOPHYLLINE IN WHOLE-BLOOD

被引:24
|
作者
ATHEY, D
MCNEIL, CJ
BAILEY, WR
HAGER, HJ
MULLEN, WH
RUSSELL, LJ
机构
[1] UNIV NEWCASTLE UPON TYNE, SCH MED, DEPT CLIN BIOCHEM, NEWCASTLE UPON TYNE NE2 4HH, ENGLAND
[2] CAMBRIDGE LIFE SCI PLC, ELY CB7 4DT, ENGLAND
来源
BIOSENSORS & BIOELECTRONICS | 1993年 / 8卷 / 9-10期
关键词
HOMOGENEOUS AMPEROMETRIC IMMUNOASSAY; THEOPHYLLINE; PLATINIZED ACTIVATED CARBON; NADH; EMIT;
D O I
10.1016/0956-5663(93)80026-L
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A homogeneous spectrophotometric EMIT immunoassay kit for the quantitation of theophylline in serum or plasma has been modified to produce a rapid, amperometric immunoassay requiring a 50 mu l whole blood sample. The basis of the detection system for the assay is the electrochemical oxidation of NADH produced by G6PDH-labelled theophylline at a potential of +150 mV vs Ag/AgCl using platinised activated carbon (PACE) electrodes. Comparison of the amperometric whole blood method with the conventional spectrophotometric plasma assay produced a reasonable correlation: y = 0.90x - 1.01, (r = 0.98, n = 12). The advantage of the new method is that simple and robust instrumentation can rapidly determine theophylline in whole blood with no sample pre-treatment or separation steps.
引用
收藏
页码:415 / 419
页数:5
相关论文
共 50 条
  • [1] HOMOGENEOUS IMMUNOASSAY OF WHOLE-BLOOD SAMPLES
    MERENBLOOM, BK
    OBERHARDT, BJ
    CLINICAL CHEMISTRY, 1995, 41 (09) : 1385 - 1390
  • [2] CHEMILUMINESCENCE IMMUNOASSAY OF CYCLOSPORINE IN WHOLE-BLOOD
    STABLER, TV
    SIEGEL, AL
    CLINICAL CHEMISTRY, 1990, 36 (06) : 906 - 908
  • [3] A RAPID WHOLE-BLOOD IMMUNOASSAY SYSTEM
    RYLATT, DB
    KEMP, BE
    BUNDESEN, PG
    JOHN, MA
    OREILLY, EJ
    COTTIS, LE
    MILES, SJ
    KHAN, JM
    DINH, DP
    STAPLETON, D
    HILLYARD, CJ
    MEDICAL JOURNAL OF AUSTRALIA, 1990, 152 (02) : 75 - 77
  • [4] A NOVEL PROCEDURE FOR THE ANALYSIS OF DRUGS IN WHOLE-BLOOD BY HOMOGENEOUS ENZYME-IMMUNOASSAY (EMIT)
    LEWELLEN, LJ
    MCCURDY, HH
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1988, 12 (05) : 260 - 264
  • [5] EVALUATION OF WHOLE-BLOOD THEOPHYLLINE ENZYME IMMUNOCHROMATOGRAPHY ASSAY
    HABIB, MP
    SCHIFMAN, RB
    SHON, BY
    FIASTRO, JF
    CAMPBELL, SC
    CHEST, 1987, 92 (01) : 129 - 131
  • [6] EVALUATION OF A WHOLE-BLOOD THEOPHYLLINE TEST REQUIRING NO INSTRUMENT
    CONBOY, C
    ELLIS, E
    JENNE, J
    SHAUGHNESSY, T
    SZEFLER, S
    WIENER, M
    MILAVETZ, G
    VAUGHAN, L
    WEINBERGER, M
    CARRICO, J
    TILLSON, S
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1985, 75 (01) : 128 - 128
  • [7] THEOPHYLLINE CONCENTRATIONS IN SERUM, PLASMA, AND WHOLE-BLOOD COMPARED
    FERRON, LA
    WEBER, JP
    HEBERT, J
    BEDARD, PM
    CLINICAL CHEMISTRY, 1985, 31 (08) : 1415 - 1416
  • [8] AMPEROMETRIC GLUCOSE BIOSENSOR FOR AN UNDILUTED WHOLE-BLOOD ANALYSIS
    MATUSZEWSKI, W
    TROJANOWICZ, M
    LEWENSTAM, A
    MOSZCZYNSKA, A
    LANGEMOROZ, E
    ANALYTICAL SCIENCES, 1994, 10 (03) : 423 - 428
  • [9] STABILITY OF THEOPHYLLINE IN HUMAN-SERUM AND WHOLE-BLOOD
    JOHNSON, CE
    COHEN, IA
    BICKLEY, SK
    HYDER, DM
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1984, 41 (10): : 2065 - 2068
  • [10] CYCLOSPORINE MONITORING BY FLUORESCENCE POLARIZATION IMMUNOASSAY OF WHOLE-BLOOD
    JOYCE, BG
    BACCHUS, R
    ANNALS OF SAUDI MEDICINE, 1989, 9 (01) : 52 - 54