HIGH-STRENGTH BOLTS FOR BRIDGES

被引:0
|
作者
VERMA, KK [1 ]
BECKMANN, FR [1 ]
机构
[1] AMER INST STEEL CONSTRUCT, CHICAGO, IL USA
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The use of substandard and mismatched bolts continues to be a major concern to bridge owners in the United States. Based on FHWA-sponsored research at the University of Texas, supplemental specifications were developed and issued modifying fastener manufacturing, testing, and installation procedures. Nearly all bridge bolts are designed for dynamic loading. They are designed to resist either tension forces and/or shear forces. Fatigue concerns govern bolts designed for cyclic tension forces. Cyclic shear forces require slip critical connections. Both loading conditions require bolts to be installed to a minimum preload. The FHWA recommendations were developed in order to assure the ability of bolts to achieve this preload. Minimum nut strength is increased, maximum bolt strength is reduced, thread fit tolerance is reduced, additional rotational-capacity testing is required, and additional testing, documentation, handling and shipping requirements are imposed. The rationale for these new FHWA provisions are discussed. Finally, slip critical joints depend upon friction between faying surfaces to develop strength. Values of slip resistance or coefficient of friction for various paints and coatings must be determined by testing. Bolt design parameters depend upon minimum values of tested coatings.
引用
收藏
页码:4 / 11
页数:8
相关论文
共 50 条
  • [1] High-strength bolts for bridges
    Verma, Krishna K., 1600, (29):
  • [2] Failure analysis of high-strength bolts in steel truss bridges
    Zhou, Man
    Yang, Dingyi
    Hassanein, Mostafa Fahmi
    Zhang, Jiandong
    An, Lin
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-CIVIL ENGINEERING, 2017, 170 (04) : 175 - 179
  • [3] High-strength bolts
    Kulak, Geoffrey L.
    Modern Steel Construction, 1995, 35 (03): : 42 - 47
  • [4] FAILURE IN HIGH-STRENGTH BOLTS
    不详
    MACHINE DESIGN, 1978, 50 (10) : 115 - 115
  • [5] 1600037 Failure analysis of high-strength bolts in steel truss bridges Discussion
    Zhou, Man
    Yang, Dingyi
    Hassanein, Mostafa Fahmi
    Zhang, Jiandong
    An, Lin
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-CIVIL ENGINEERING, 2018, 171 (01) : 19 - 19
  • [6] Axial-force inference system of high-strength bolts of steel bridges
    Mikami, I
    Tanaka, S
    Hiwatashi, T
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON COMPUTING IN CIVIL AND BUILDING ENGINEERING, VOLS 1-4, 1997, : 325 - 330
  • [7] Tightening of high-strength bolts on structures
    Piraprez, Eugene
    Construction Metallique, 1988, 25 (04): : 35 - 47
  • [8] Flange connections with high-strength bolts with technological heredity of bolts
    Vatin, N.
    Gubaydulin, R. G.
    Tingaev, A.
    MAGAZINE OF CIVIL ENGINEERING, 2020, 99 (07):
  • [9] Shear strength of high-strength bolts at elevated temperature
    Yang, Kuo-Chen
    Hsu, Re-Jia
    Chen, Yan-Jun
    CONSTRUCTION AND BUILDING MATERIALS, 2011, 25 (08) : 3656 - 3660
  • [10] A study of high-strength bolts after dephosphoring
    Hsia, Shao-Yi
    Chou, Yu-Tuan
    Chao, Jung-Chi
    ADVANCES IN MECHANICAL ENGINEERING, 2016, 8 (03) : 1 - 10