A NEW TECHNIQUE FOR LOCATION OF TRANSMISSION-LINE FAULTS USING SINGLE-TERMINAL VOLTAGE AND CURRENT DATA

被引:0
|
作者
YOUSSEF, OAS
机构
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new technique for location of transmission line faults using voltage and current measurements from one end of the faulted line. The method differs from past techniques in many respects. The main feature of the new technique is that it considers the influence of the remote-end infeed of the transmission line, the effect of the transmission line capacitance, fault resistance, prefault loading conditions, and the effect of mutual coupling between different phases of the line, and then computes with a microprocessor the distance to the fault point without any approximations. It uses recorded phase voltages and currents at the near end, then the fundamental components of the measured signals are extracted using microprocessor filters. The modal values of the extracted signals are computed then processed to indicate the precise location of the fault.
引用
收藏
页码:123 / 128
页数:6
相关论文
共 50 条
  • [2] Single-terminal line protection for UHVDC power transmission based on voltage backward traveling wave
    Dai Z.
    Liu N.
    Liu Y.
    Lu H.
    Cao H.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (09): : 80 - 87
  • [3] Single-Terminal Travelling Wave Based Fault Location Method in T-Type Transmission Line
    Liu, Sentao
    Liu, Harming
    Li, Xin
    Fang, Tingting
    Sun, Yongjian
    Liu, Yuling
    2022 IEEE/IAS INDUSTRIAL AND COMMERCIAL POWER SYSTEM ASIA (I&CPS ASIA 2022), 2022, : 427 - 432
  • [4] Calculation of voltage sag amplitude for single-terminal trip of faulty line
    Lan, Jian
    Wang, Dongxu
    Ye, Xi
    Liu, Kaipei
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2014, 34 (08): : 78 - 82
  • [5] New method of single-terminal fault location for HV transmission line based on fuzzy theory (part I. Theoretical analysis)
    Quan, Yusheng
    Wang, Xiaorong
    Yang, Minzhong
    Yan, Zhang
    Hou, Chenglin
    Si, Ludong
    Tong, Ke
    Liu, Xiaofeng
    Li, Xiaobing
    Yu, Zheng
    Kang, Linxian
    Gaodianya Jishu/High Voltage Engineering, 1999, 25 (04): : 11 - 14
  • [6] Unsynchronised two-terminal transmission-line fault-location without using line parameters
    Liao, Y.
    Elangovan, S.
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2006, 153 (06) : 639 - 643
  • [7] A new fault-location method for HVDC transmission-line based on DC components of voltage and current under line parameter uncertainty
    Mohammad Daisy
    Rahman Dashti
    Hamid Reza Shaker
    Electrical Engineering, 2017, 99 : 573 - 582
  • [8] A new fault-location method for HVDC transmission-line based on DC components of voltage and current under line parameter uncertainty
    Daisy, Mohammad
    Dashti, Rahman
    Shaker, Hamid Reza
    ELECTRICAL ENGINEERING, 2017, 99 (02) : 573 - 582
  • [9] NEW TECHNIQUE TO MEASURE TRANSMISSION-LINE ATTENUATION
    CARROLL, J
    LI, M
    CHANG, K
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1995, 43 (01) : 219 - 222
  • [10] CURRENT LOAD IN A HIGH-VOLTAGE POWER TRANSMISSION-LINE
    LIN, SH