IMPROVEMENT OF SOS UMU TEST AS A SHORT-TERM DETECTION OF MUTAGENS

被引:0
|
作者
AOKI, T [1 ]
OMORI, M [1 ]
OGURO, H [1 ]
NAKAMURA, S [1 ]
机构
[1] OSAKA PREFECTURAL INST PUBL HLTH,HIGASHINARI KU,OSAKA 537,JAPAN
关键词
D O I
10.1246/nikkashi.1991.422
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A short-term system to detect environmental mutagens is presented by using a plasmid (pSK 1002) carring a fused gene umuC-lacZ introduced into Salmonella typhimurium TA 1535. The principle of this test is that when mutagens in sample attack the DNA in the tester strain, beta-galactosidase is produced in propotion to the amount of the mutagens and then reacts with omicron-nitrophenyl-beta-D-galactopyranoside (ONPG) to produce omicron-nitrophenol which can be detected at 420 nm. This method showed 12 times higher sensitivity than the previous method when AF-2 was used as test compound, and major improvements made by us are as follows ; (1) in order to determine the amount of produced enzyme, the volume of culture treated with the test compound was increased from 0.25 ml to 1.0 ml, (2) the poly(oxyethylene) (23)dodecyl ether and toluene were selected as loosening reagents of the cell membrane, and (3) one ml of ONPG (4 mg.l-1) and 45 min of reaction time were adopted. This method was applied to mutangenicity test of river waters to which clorine and chlorine-alternative disinfectants such as, chloramine, chlorine dioxide, and ozone were added.
引用
收藏
页码:422 / 426
页数:5
相关论文
共 50 条
  • [1] IMPROVEMENT OF THE SOS/UMU TEST FOR PRELIMINARY SCREENING OF MUTAGENS
    AOKI, T
    NAKAMURA, S
    ODA, Y
    ANALYTICAL LETTERS, 1989, 22 (11-12) : 2463 - 2469
  • [2] DETECTION OF MUTAGENS USING THE UMU TEST KIT
    SHIBAHARA, T
    KODAIRA, T
    YOSHIDA, S
    NAKAJIMA, K
    MUTATION RESEARCH, 1986, 164 (04): : 279 - 280
  • [3] A SIMPLE TEST SYSTEM (UMU TEST) FOR THE DETECTION OF ENVIRONMENTAL MUTAGENS .6. INDUCTION OF THE SOS RESPONSES BY NORHARMAN AND HARMAN
    ODA, Y
    NAKAMURA, S
    OKI, I
    MUTATION RESEARCH, 1987, 182 (06): : 372 - 373
  • [4] A SIMPLE TEST SYSTEM (UMU TEST) FOR THE DETECTION OF ENVIRONMENTAL MUTAGENS .7. INHIBITORY EFFECTS OF CURCUMIN ON THE SOS RESPONSES INDUCED BY UV AND CHEMICAL MUTAGENS
    ODA, Y
    NAKAMURA, S
    OKI, I
    MUTATION RESEARCH, 1988, 203 (05): : 384 - 384
  • [5] THE ADVANTAGES AND LIMITATIONS OF THE BACTERIAL SHORT-TERM TEST SOS CHROMOTEST FOR THE DETECTION OF GENOTOXIC AGENTS
    VASILIEVA, S
    MUTATION RESEARCH, 1989, 216 (05): : 289 - 289
  • [6] FLUOROMETRIC UMU-TEST AND ADA-TEST FOR DETECTION OF MUTAGENS IN FOOD
    TOMITA, I
    ANANTASINKUL, N
    SHIMOI, K
    OKADA, Y
    MATSUUCHI, K
    MARUYAMA, T
    HASHIZUME, T
    NAKAMURA, Y
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 1992, 33 (02): : 171 - 175
  • [7] DETECTION OF IONIZING-RADIATIONS WITH THE SOS CHROMOTEST, A BACTERIAL SHORT-TERM TEST FOR GENOTOXIC AGENTS
    QUILLARDET, P
    FRELAT, G
    NGUYEN, VD
    HOFNUNG, M
    MUTATION RESEARCH, 1989, 216 (05): : 251 - 257
  • [8] Mutagenicity test system based on a reporter gene assay for short-term detection of mutagens (MutaGen assay)
    Schmid, C
    Arndt, C
    Reifferscheid, G
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2003, 535 (01) : 55 - 72
  • [9] SHORT-TERM TESTS FOR CARCINOGENS AND MUTAGENS
    HOLLSTEIN, M
    MCCANN, J
    ANGELOSANTO, FA
    NICHOLS, WW
    MUTATION RESEARCH, 1979, 65 (03): : 133 - 226
  • [10] A SIMPLE TEST SYSTEM (UMU-TEST) FOR THE DETECTION OF ENVIRONMENTAL MUTAGEN .4. EVALUATION OF UMU-TEST FOR DETECTION OF POTENTIAL CHEMICAL MUTAGENS
    NAKAMURA, S
    ODA, Y
    NAKATA, A
    SHINAGAWA, H
    MUTATION RESEARCH, 1985, 147 (05): : 267 - 267