INFLUENCE OF VENTILATION RATE ON INDOOR RADON CONCENTRATION - THEORETICAL EVALUATION AND EXPERIMENTAL-DATA IN A TEST CHAMBER

被引:5
|
作者
CAPRA, D
SILIBELLO, C
QUEIRAZZA, G
机构
[1] CISE SpA, Milan, Via Reggio Emilia, 39
[2] ENEL SpA, DSR-CRAM, 20134 Milan, Via Rubattino
关键词
D O I
10.1016/0265-931X(94)90040-X
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper describes research activities performed to evaluate the different contribution of various sources to indoor radon levels. Underlying soil, building materials and outdoor air are considered as sources of indoor radon. The relative contributions of the three sources are estimated by applying experimental and theoretical techniques to a test chamber in which several parameters are monitored. The effects produced by the increase in ventilation rate are evaluated in terms of influence on indoor radon levels.
引用
收藏
页码:205 / 215
页数:11
相关论文
共 31 条
  • [1] INFLUENCE OF VENTILATION RATE ON INDOOR RADON CONCENTRATION IN A TEST CHAMBER
    CAPRA, D
    SILIBELLO, C
    QUEIRAZZA, G
    RADIATION PROTECTION DOSIMETRY, 1994, 56 (1-4) : 15 - 18
  • [2] Measuring radon exhalation rate by tracing the radon concentration of ventilation-type accumulation chamber
    Tan, Yanliang
    Xiao, Detao
    Liu, Xiaosong
    Tang, Quan
    RADIATION MEASUREMENTS, 2013, 58 : 33 - 36
  • [3] An Environmental Evaluation of Ventilation Systems Aimed at Reducing Indoor Radon Concentration
    Felicioni, Licia
    Jiranek, Martin
    Vlasata, Barbora
    Lupisek, Antonin
    BUILDINGS, 2023, 13 (11)
  • [4] INDOOR RADON CONCENTRATION AND ITS POSSIBLE DEPENDENCE ON VENTILATION RATE AND FLOORING TYPE
    Ashok, G. V.
    Nagaiah, N.
    Prasad, N. G. Shiva
    RADIATION PROTECTION DOSIMETRY, 2012, 148 (01) : 92 - 100
  • [5] Successful reduction of indoor radon activity concentration via cross-ventilation: experimental data and CFD simulations
    Altendorf, Diana
    Wienkenjohann, Henning
    Berger, Florian
    Dehnert, Joerg
    Gruenewald, Hannes
    Naumov, Dmitri
    Trabitzsch, Ralf
    Weiss, Holger
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2024, 60 (01) : 74 - 89
  • [6] THEORETICAL AND EXPERIMENTAL EVALUATION OF AN INDOOR ROCKET TEST STAND
    KORTING, PAOG
    REITSMA, HJ
    JOURNAL OF SPACECRAFT AND ROCKETS, 1983, 20 (03) : 266 - 271
  • [7] Variation of indoor radon concentration in a walk-in type test chamber under controlled environmental conditions
    Joshi, Abhishek
    Panwar, Pooja
    Prasad, Mukesh
    Singh, Krishna Pal
    Ramola, R. C.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (06) : 3055 - 3064
  • [8] EVALUATION OF EXPERIMENTAL-DATA ON RATE OF SORPTION BY DIGITAL-COMPUTER
    VARGA, K
    FEJES, P
    MAGYAR KEMIKUSOK LAPJA, 1974, 29 (03): : 152 - 155
  • [9] Correlations between radon concentration and indoor gamma dose rate, soil permeability and dwelling substructure and ventilation
    Mäkeläinen, I
    Arvela, H
    Voutilainen, A
    SCIENCE OF THE TOTAL ENVIRONMENT, 2001, 272 (1-3) : 283 - 289
  • [10] COMPUTATIONAL METHOD FOR MATCHING AERODYNAMIC EXPERIMENTAL-DATA WITH THEORETICAL INFLUENCE MATRICES
    PONZI, C
    JOURNAL OF AIRCRAFT, 1993, 30 (01): : 133 - 135