DEVELOPMENT AND TESTING OF A HIGH-TEMPERATURE QUARTZ-CRYSTAL MICROBALANCE

被引:21
|
作者
MECEA, VM
CARLSSON, JO
HESZLER, P
BARTAN, M
机构
[1] Ångström Consortium, Department of Inorganic Chemistry, Uppsala University, S-751 21 Uppsala
关键词
D O I
10.1016/0042-207X(94)00147-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A high temperature quartz crystal microbalance (HTQCM) was developed in order to extend its application range up to the Curie point (573 degrees C) of the quartz resonators. It is shown that well matched quartz crystal resonators and even better, a dual resonator working in a differential measuring system, can minimize the temperature effect on the measuring signal, allowing mass measurements with an accuracy of 2 x 10(-12) g cm(-2) s(-1). The HTQCM was tested by measuring the sublimation rates of C-60 fullerene in a temperature range of 250 degrees C to 360 degrees C. In addition, the HTQCM was successfully tested during laser induced carbon deposition at a substrate temperature of up to 500 degrees C.
引用
收藏
页码:691 / 694
页数:4
相关论文
共 50 条
  • [1] THE ELECTROCHEMICAL QUARTZ-CRYSTAL MICROBALANCE
    PODHAJECKY, P
    BRODSKA, S
    PAPEZ, V
    CHEMICKE LISTY, 1995, 89 (04): : 251 - 255
  • [2] QUARTZ-CRYSTAL MICROBALANCE FOR IMMUNOSENSING
    KOSSLINGER, C
    DROST, S
    ABERL, F
    WOLF, H
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (05): : 349 - 354
  • [3] DUAL QUARTZ-CRYSTAL MICROBALANCE
    DUNHAM, GC
    BENSON, NH
    PETELENZ, D
    JANATA, J
    ANALYTICAL CHEMISTRY, 1995, 67 (02) : 267 - 272
  • [4] QUARTZ-CRYSTAL MICROBALANCE SENSOR IN LIQUIDS
    AUGE, J
    HAUPTMANN, P
    EICHELBAUM, F
    ROSLER, S
    SENSORS AND ACTUATORS B-CHEMICAL, 1994, 19 (1-3) : 518 - 522
  • [5] QUARTZ-CRYSTAL MICROBALANCE BIOAFFINITY SENSOR FOR BIOTIN
    MASSON, M
    YUN, KS
    HARUYAMA, T
    KOBATAKE, E
    AIZAWA, M
    ANALYTICAL CHEMISTRY, 1995, 67 (13) : 2212 - 2215
  • [6] ATS-6 - QUARTZ-CRYSTAL MICROBALANCE
    ROGERS, JF
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1975, 11 (06) : 1185 - 1186
  • [7] OSTEOBLAST ATTACHMENT MONITORED WITH A QUARTZ-CRYSTAL MICROBALANCE
    REDEPENNING, J
    SCHLESINGER, TK
    MECHALKE, EJ
    PULEO, DA
    BIZIOS, R
    ANALYTICAL CHEMISTRY, 1993, 65 (23) : 3378 - 3381
  • [8] QUARTZ-CRYSTAL MICROBALANCE STUDY OF PLATINUM AMALGAMATION
    CHEEK, GT
    OGRADY, WE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 331 - PHYS
  • [9] High-stability quartz-crystal microbalance for investigations in surface science
    Bouzidi, L
    Narine, SS
    Stefanov, KG
    Slavin, AJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (06): : 3039 - 3044
  • [10] BEHAVIOR OF QUARTZ-CRYSTAL MICROBALANCE IN NONADSORBED GASES AT HIGH-PRESSURES
    TSIONSKY, V
    DAIKHIN, L
    URBAKH, M
    GILEADI, E
    LANGMUIR, 1995, 11 (02) : 674 - 678