Automatic contouring of brachial plexus using a multi-atlas approach for lung cancer radiation therapy

被引:33
|
作者
Yang, Jinzhong [1 ]
Amini, Arya [2 ,3 ]
Williamson, Ryan [1 ]
Zhang, Lifei [1 ]
Zhang, Yongbin [1 ]
Komaki, Ritsuko [3 ]
Liao, Zhongxing [3 ]
Cox, James [3 ]
Welsh, James [3 ]
Court, Laurence [1 ]
Dong, Lei [1 ,4 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Calif Irvine, Sch Med, Irvine, CA 92717 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[4] Scripps Proton Therapy Ctr, San Diego, CA USA
关键词
D O I
10.1016/j.prro.2013.01.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To demonstrate a multi-atlas segmentation approach to facilitating accurate and consistent delineation of low-contrast brachial plexuses on computed tomographic images for lung cancer radiation therapy. Methods and Materials: We retrospectively identified 90 lung cancer patients with treatment volumes near the brachial plexus. Ten representative patients were selected to form an atlas group, and their brachial plexuses were delineated manually. We used deformable image registration to map each atlas brachial plexus to the remaining 80 patients. In each patient, a composite contour was created from 10 individual segmentations using the simultaneous truth and performance level estimation algorithm. This auto-delineated contour was reviewed and modified appropriately for each patient. We also performed 10 leave-one-out tests using the 10 atlases to validate the segmentation accuracy and demonstrate the contouring consistency using multi-atlas segmentation. Results: The multi-atlas segmentation took less than 2 minutes to complete. Contour modification took 5 minutes compared with 20 minutes for manual contouring from scratch. The multi-atlas segmentation from the 10 leave-one-out tests had a mean 3-dimensional (3D) volume overlap of 59.2% +/- 8.2% and a mean 3D surface distance of 2.4 mm +/- 0.5 mm. The distances between the individual and average contours in the 10 leave-one-out tests demonstrated much better contouring consistency for modified contours than for manual contours. The auto-segmented contours did not require substantial modification, demonstrated by the good agreement between the modified and auto-segmented contours in the 80 patients. Dose volume histograms of auto-segmented and modified contours were also in good agreement, showing that editing auto-segmented contours is clinically acceptable in view of the dosimetric impact. Conclusions: Multi-atlas segmentation greatly reduced contouring time and improved contouring consistency. Editing auto-segmented contours to delineate the brachial plexus proved to be a better clinical practice than manually contouring from scratch. (C) 2013 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:E139 / E147
页数:9
相关论文
共 50 条
  • [1] Atlas Development for Cardiac Automatic Contouring Using Multi-Atlas Segmentation
    Zhou, R.
    Yang, J.
    Pan, T.
    Milgrom, S.
    Pinnix, C.
    Shi, A.
    Yang, J.
    Liu, Y.
    Nguyen, Q.
    Gomez, D.
    Dabaja, B.
    Baiter, P.
    Court, L.
    Liao, Z.
    MEDICAL PHYSICS, 2015, 42 (06) : 3294 - 3294
  • [2] Atlas-Based Segmentation: Evaluation of a Multi-Atlas Approach for Lung Cancer
    Pirozzi, S.
    Horvat, M.
    Piper, J.
    Nelson, A.
    MEDICAL PHYSICS, 2012, 39 (06) : 3677 - 3677
  • [3] Brachial Plexus Contouring with CT and MR Imaging in Radiation Therapy Planning for Head and Neck Cancer
    Minh Tam Truong
    Nadgir, Rohini N.
    Hirsch, Ariel E.
    Subramaniam, Rathan M.
    Wang, Jimmy W.
    Wu, Rebecca
    Khandekar, Melin
    Nawaz, A. Omer
    Sakai, Osamu
    RADIOGRAPHICS, 2010, 30 (04) : 1095 - 1103
  • [4] AUTOMATIC MULTI-ATLAS SEGMENTATION USING DUAL REGISTRATIONS
    Suh, J. W.
    Schaap, M.
    Lee, A.
    Do, N.
    Ahiekpor-Dravi, A.
    Bai, Y.
    Choi, G.
    Moreau-Gobard, R.
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 1284 - 1287
  • [5] Optimal number of atlases and label fusion for automatic multi-atlas-based brachial plexus contouring in radiotherapy treatment planning
    Joris Van de Velde
    Johan Wouters
    Tom Vercauteren
    Werner De Gersem
    Eric Achten
    Wilfried De Neve
    Tom Van Hoof
    Radiation Oncology, 11
  • [6] Optimal number of atlases and label fusion for automatic multi-atlas-based brachial plexus contouring in radiotherapy treatment planning
    Van de Velde, Joris
    Wouters, Johan
    Vercauteren, Tom
    De Gersem, Werner
    Achten, Eric
    De Neve, Wilfried
    Van Hoof, Tom
    RADIATION ONCOLOGY, 2016, 11
  • [7] Multi-Atlas Based Automatic Organ Segmentation for Lung Radiotherapy Planning
    Kim, J.
    Han, J.
    Ailawadi, S.
    Baker, J.
    Hsia, A.
    Xu, Z.
    Ryu, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3433 - 3433
  • [8] The effect of morphometric atlas selection on multi-atlas-based automatic brachial plexus segmentation
    Van de Velde, Joris
    Wouters, Johan
    Vercauteren, Tom
    De Gersem, Werner
    Achten, Eric
    De Neve, Wilfried
    Van Hoof, Tom
    RADIATION ONCOLOGY, 2015, 10
  • [9] The effect of morphometric atlas selection on multi-atlas-based automatic brachial plexus segmentation
    Joris Van de Velde
    Johan Wouters
    Tom Vercauteren
    Werner De Gersem
    Eric Achten
    Wilfried De Neve
    Tom Van Hoof
    Radiation Oncology, 10
  • [10] OUT-OF-ATLAS LABELING: A MULTI-ATLAS APPROACH TO CANCER SEGMENTATION
    Asman, Andrew J.
    Landman, Bennett A.
    2012 9TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2012, : 1236 - 1239