Safety Concerns About an Epidural Blood Patch in a Patient with Extensive Epidural Fluid Accumulation
被引:0
|作者:
Droog, Wouter
[1
]
Zuidgeest, Dick M. H.
[2
]
de Jonge, Leenoud C. W.
[3
]
van Oort, Cas J.
[4
]
机构:
[1] Erasmus MC, Dept Anesthesiol, Postbus 2040, NL-3000 CA Rotterdam, Netherlands
[2] Ikazia Hosp, Dept Neurol, Rotterdam, Netherlands
[3] Ikazia Hosp, Dept Radiol, Rotterdam, Netherlands
[4] Ikazia Hosp, Dept Anesthesiol, Rotterdam, Netherlands
关键词:
D O I:
10.1213/XAA.0000000000000192
中图分类号:
R614 [麻醉学];
学科分类号:
100217 ;
摘要:
We present a case of postdural puncture headache in a patient with extensive epidural fluid accumulation. An initial epidural blood patch was aborted because of concern about increased risk of complications. After magnetic resonance imaging, we proceeded with epidural blood patch with a good therapeutic result. We discuss the imaging results and safety concerns we considered when assessing the benefits and risks of epidural blood patch in this patient.