The cooling energy requirements are a key issue for office buildings in warm climates, but they have become considerable also in temperate climates, 'cause the growing level of buildings thermal insulation. This aspect is more critical in office blocks than in residential buildings, due to the higher value of thermal energy supplied by internal loads. Office buildings are usually equipped with cooling systems in order to guarantee thermal comfort conditions for the office workers. The aim of this work is the evaluation of energy saving reachable in office blocks cooling requirements, using a water indirect free cooling operating procedure for the plant. It is assumed that the HVAC plant is equipped with dry-coolers that work as coolers of the refrigeration equipment condensers or just as coolers of the water to be supplied to fan coils. As the more solar radiation there is, the more cooling power is needed, dry-coolers, equipped with on-board photovoltaic panels, have been considered. The cooling loads of the office block have been evaluated through Energy Plus hourly time-step simulations for different climate conditions. Finally, electrical consumption of dry-c and energy produced by PV panels in different climates and with different tilts have been evaluated and compared.
引用
收藏
页码:S205 / S211
页数:7
相关论文
共 50 条
  • [1] Savings in Cooling Energy with a Thermal Management System for LED Lighting in Office Buildings
    Ahn, Byung-Lip
    Park, Ji-Woo
    Yoo, Seunghwan
    Kim, Jonghun
    Leigh, Seung-Bok
    Jang, Cheol-Yong
    ENERGIES, 2015, 8 (07): : 6658 - 6671
  • [2] A simplified method to estimate cooling energy savings from night ventilation for office buildings
    Liu, Xiang
    Krarti, Moncef
    PROCEEDINGS OF THE ENERGY SUSTAINABILITY CONFERENCE 2007, 2007, : 781 - 786
  • [3] ENERGY CHARACTERISTICS AND SAVINGS POTENTIAL IN OFFICE BUILDINGS
    SANTAMOURIS, M
    ARGIRIOU, A
    DASCALAKI, E
    BALARAS, C
    GAGLIA, A
    SOLAR ENERGY, 1994, 52 (01) : 59 - 66
  • [4] Air quality and energy savings in school and office buildings
    Nagy, Richard
    Kosicanova, Danica
    Lojkovics, Jan
    9TH INTERNATIONAL CONFERENCE ENVIRONMENTAL ENGINEERING (9TH ICEE) - SELECTED PAPERS, 2014,
  • [5] Impact of electricity rate structures on energy cost savings of pre-cooling controls for office buildings
    Morgan, Stephen
    Krarti, Moncef
    BUILDING AND ENVIRONMENT, 2007, 42 (08) : 2810 - 2818
  • [6] Energy consumption, energy savings, and emission analysis in Malaysian office buildings
    Saidur, R.
    ENERGY POLICY, 2009, 37 (10) : 4104 - 4113
  • [7] Energy Savings of Occupancy-Based Controls in Office Buildings
    Wang, Weimin
    Zhang, Jian
    Brambley, Michael
    Futrell, Benjamin
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 932 - 939
  • [8] Free-cooling potential in shopping mall buildings with plants equipped by dry-coolers boosted with evaporative pads
    De Angelis A.
    Chinese D.
    Saro O.
    1600, International Information and Engineering Technology Association (35): : 853 - 862
  • [9] ENERGY-SAVING SOLUTIONS FOR THE COOLING OF THE OFFICE BUILDINGS
    Ferdyn-Grygierek, Joanna
    Baranowski, Andrzej
    RYNEK ENERGII, 2009, (01): : 46 - 52
  • [10] The effect of geometry factors on fenestration energy performance and energy savings in office buildings
    Susorova, Irina
    Tabibzadeh, Meysam
    Rahman, Anisur
    Clack, Herek L.
    Elnimeiri, Mahjoub
    ENERGY AND BUILDINGS, 2013, 57 : 6 - 13