We compared the conspicuity of acute pulmonary emboli with contrast-enhanced spiral computed tomography (CT) and two- and three-dimensional time-of-flight magnetic resonance (MR) techniques. Seven dogs who received experimental pulmonary emboli and one control were imaged with spiral CT and with 2-D (FMPVAS and FASTCARD) and 3-D time-of-flight MR. Blinded, independent, prospective evaluations of the CT and MR images by two MR radiologists and two chest radiologists were then compared to the location of the emboli as determined by subsequent pathologic evaluation of the excised lungs. Embolus/blood contrast-to-noise ratios (CNRs) were calculated on both MR and CT images for pulmonary emboli that could be identified. Fifty emboli ranging from 1.0 to 5.5 mm (mean, 2.7, +/- 0.14 SEM) in diameter and from 3.0 to 60 min (mean, 28.1, +/- 1.9 SEM) in length were found in the seven embolized dogs on pathologic examination. Three of the four radiologists identified more thrombi on CT images than they did on their best MR pulse sequence (FASTCARD) and with greater confidence. The fourth radiologist identified an equal percentage of clot on CT and FASTCARD images with confidence slightly greater on FASTCARD MR than on spiral CT. Mean CNR for the best MR technique was 43.4 (+/-3.9 SEM) and for CT was 20.7 (+/-1.3 SEM). In general, pulmonary emboli were detected more accurately on contrast-enhanced spiral CT than on MR. This occurred although the embolus/blood CNR was higher on MR than on CT. Better pulmonary embolus conspicuity on CT images was attributed to better spatial resolution and fewer artifacts on CT than on MR. One MR radiologist performed equally wen with both spiral CT and FASTCARD techniques, suggesting that experience may be a factor in performance.
引用
收藏
页码:59 / 72
页数:14
相关论文
共 50 条
  • [1] Pulmonary embolism: Comparison of gadolinium-enhanced MR angiography with contrast-enhanced spiral CT in a porcine model
    Reittner, P
    Coxson, HO
    Nakano, Y
    Heyneman, L
    Ward, S
    King, GG
    Baile, EM
    Mayo, JR
    [J]. ACADEMIC RADIOLOGY, 2001, 8 (04) : 343 - 350
  • [2] 3.0-tesla MR angiography of intracranial aneurysms: Comparison of time-of-flight and contrast-enhanced techniques
    Gibbs, GF
    Huston, J
    Bernstein, MA
    Riederer, SJ
    Brown, RD
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (02) : 97 - 102
  • [3] Identification of Intraplaque Hemorrhage on MR Angiography Images: A Comparison of Contrast-Enhanced Mask and Time-of-Flight Techniques
    Qiao, Y.
    Etesami, M.
    Malhotra, S.
    Astor, B. C.
    Virmani, R.
    Kolodgie, F. D.
    Trout, H. H., III
    Wasserman, B. A.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (03) : 454 - 459
  • [4] Comparison of Carotid Plaque Ulcer Detection Using Contrast-Enhanced and Time-of-Flight MRA Techniques
    Etesami, M.
    Hoi, Y.
    Steinman, D. A.
    Gujar, S. K.
    Nidecker, A. E.
    Astor, B. C.
    Portanova, A.
    Qiao, Y.
    Abdalla, W. M. A.
    Wasserman, B. A.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (01) : 177 - 184
  • [5] Contrast-enhanced spiral CT is comparable to pulmonary angiography for the diagnosis of pulmonary embolism
    Baile, EM
    Mayo, JR
    King, GG
    Muller, NL
    Coche, EC
    Pare, PD
    [J]. RADIOLOGY, 1999, 213P : 127 - 127
  • [6] COMPARISON OF TIME-OF-FLIGHT AND PHASE-CONTRAST MR NEUROANGIOGRAPHIC TECHNIQUES
    HUSTON, J
    EHMAN, RL
    [J]. RADIOGRAPHICS, 1993, 13 (01) : 5 - 19
  • [7] Pulmonary embolism: Comparision between perfusion angiography MRI and contrast-enhanced spiral CT
    Fernandez, GC
    Tardaguila, FM
    Trinidad, C
    Rodriguez-Castilla, M
    Martinez, CM
    Hortas, M
    [J]. RADIOLOGY, 2002, 225 : 151 - 151
  • [8] DETECTION OF BRAIN METASTASES - COMPARISON OF CONTRAST-ENHANCED MR WITH UNENHANCED MR AND ENHANCED CT
    SZE, G
    MILANO, E
    JOHNSON, C
    HEIER, L
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1990, 11 (04) : 785 - 791
  • [9] Contrast-enhanced MR angiography at 3T in the evaluation of intracranial aneurysms: A comparison with time-of-flight MR angiography
    Nael, K.
    Villablanca, J. P.
    Saleh, R.
    Pope, W.
    Nael, A.
    Laub, G.
    Finn, J. P.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (10) : 2118 - 2121
  • [10] A comparison of time-of-flight mr angiography, contrast-enhanced mr angiography and ct angiography to evaluate vessel area in a rabbit peripheral arterial disease model
    Yi Xu
    Y Fu
    D Kedziorek
    N Azene
    T Ehtiati
    A Flamang
    SM Shea
    DL Kraitchman
    [J]. Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)