INFLUENCE OF THE ELECTRIC-FIELD ON COMPENSATION IN A URANIUM TETRAMETHYLPENTANE HADRONIC CALORIMETER

被引:9
|
作者
BACCI, C
BEZAGUET, A
BLOESS, D
CANER, A
CAVANNA, F
DIEZHEDO, FJ
DRIJARD, D
DUMPS, L
DICIACCIO, A
EVANS, H
FERRANDO, A
GIVERNAUD, A
GONIDEC, A
JOSA, MI
KRAMMER, M
LACAVA, F
LINDGREN, M
MARKOU, C
MAURIN, G
MORGAN, K
MUNOZ, RC
NAUMANN, L
PETROLO, E
PLACCI, A
PONTECORVO, L
RADERMACHER, E
ROBINSON, D
RODRIGO, T
RUBBIA, C
SALICIO, JM
SCHINZEL, D
SEEZ, C
STUBENRAUCH, C
TORRENTELUJAN, E
TUSI, A
ULLALAND, O
VENEZIANO, S
VIRDEE, TS
VUILLEMIN, V
机构
[1] CERN,CH-1211 GENEVA 23,SWITZERLAND
[2] RHEIN WESTFAL TH AACHEN,W-5100 AACHEN,GERMANY
[3] NATL INST NUCL & HIGH ENERGY PHYS,AMSTERDAM,NETHERLANDS
[4] LAB ANNECY LE VIEUX PHYS PARTICULES,ANNECY,FRANCE
[5] CIEMAT,MADRID,SPAIN
[6] UNIV ALABAMA,BIRMINGHAM,AL 35294
[7] BOSTON UNIV,BOSTON,MA 02215
[8] UNIV HELSINKI,SF-00100 HELSINKI 10,FINLAND
[9] UNIV KIEL,W-2300 KIEL 1,GERMANY
[10] UNIV LONDON IMPERIAL COLL SCI & TECHNOL,LONDON SW7 2AZ,ENGLAND
[11] UNIV LONDON QUEEN MARY COLL,LONDON E1 4NS,ENGLAND
[12] MIT,CAMBRIDGE,MA 02139
[13] UNIV PADUA,I-35100 PADUA,ITALY
[14] COLL FRANCE,F-75231 PARIS 05,FRANCE
[15] UNIV CALIF RIVERSIDE,RIVERSIDE,CA 92521
[16] RUTHERFORD APPLETON LAB,DIDCOT OX11 0QX,OXON,ENGLAND
[17] CENS,F-91190 GIF SUR YVETTE,FRANCE
[18] UNIV CALIF LOS ANGELES,LOS ANGELES,CA 90024
[19] UNIV VIENNA,A-1010 VIENNA,AUSTRIA
关键词
D O I
10.1016/0168-9002(90)91738-W
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A uranium tetramethylpentane hadronic calorimeter has been tested using electrons and pions of 7 GeV/c momentum with electric fields varying from 0.8 to 16.0 kV/cm; the e/π charge collection ratio has been measured as a function of the electric field within this range. It is observed that the e/π ratio can be tuned acting on the electric field without spoiling the energy resolution for electrons. At the same time the energy resolution for pions is improved. The effect was cross-checked using a second module and 40 GeV/c electron and pion beams. © 1990.
引用
收藏
页码:113 / 120
页数:8
相关论文
共 50 条
  • [1] PERFORMANCE OF A URANIUM TETRAMETHYLPENTANE ELECTROMAGNETIC CALORIMETER
    ALBROW, MG
    APSIMON, R
    AUBERT, B
    BACCI, C
    BEZAGUET, A
    BONINO, R
    CENNINI, P
    CENTRO, S
    CERADINI, F
    COCHET, C
    COLAS, J
    CONTE, R
    DEBRION, JP
    DEGIORGI, M
    DICIACCIO, A
    DIEZHEDO, F
    DOWELL, JD
    DUMPS, L
    GHEZ, P
    GIVERNAUD, A
    GONIDEC, A
    KIENZLE, W
    LACAVA, F
    LOOTEN, A
    MARKIEWICZ, T
    MARKOU, C
    MAURIN, G
    MENEGUZZO, A
    MULLER, T
    MUNOZ, R
    NAUMANN, L
    OCHSENBEIN, S
    PETROLO, E
    PIGOT, C
    PLACCI, A
    PRIPSTEIN, M
    RADERMACHER, E
    ROBINSON, D
    RUBBIA, C
    SASS, J
    SCHINZEL, D
    SCHMIDT, WF
    SEEZ, C
    SEIDL, W
    STREETS, J
    SUMOROK, K
    VENEZIANO, S
    VIRDEE, TS
    WARMUTH, E
    ZANELLO, L
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 265 (1-2): : 303 - 318
  • [2] PERFORMANCE OF A URANIUM TETRAMETHYLPENTANE CALORIMETER BACKED BY AN IRON SCINTILLATOR CALORIMETER
    APSIMON, R
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 305 (02): : 331 - 343
  • [3] PERFORMANCE OF A SEMI-OCTAGONAL-SHAPED URANIUM TETRAMETHYLPENTANE CALORIMETER
    BACCI, C
    BEZAGUET, A
    BLOESS, D
    CANER, A
    CAVANNA, F
    DIEZHEDO, FJ
    DRIJARD, D
    DUMPS, L
    EVANS, H
    FERRANDO, A
    GIVERNAUD, A
    GONIDEC, A
    JOSA, MI
    KRAMMER, M
    MARQUINA, MA
    MAURIN, G
    MORGAN, K
    MUNOZ, RC
    NAUMANN, L
    NEDELEC, P
    PETROLO, E
    PLACCI, A
    PONTECORVO, L
    RADERMACHER, E
    ROBINSON, D
    RODRIGO, T
    RUBBIA, C
    SALICIO, JM
    SCHINZEL, D
    SEEZ, C
    STUBENRAUCH, C
    TEYKAL, H
    TORRENTELUJAN, E
    TUSI, A
    ULLALAND, O
    VENEZIANO, S
    VIRDEE, TS
    VUILLEMIN, V
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 301 (03): : 445 - 450
  • [4] PERFORMANCE OF A COMBINED URANIUM TETRAMETHYLPENTANE CALORIMETER WITH DIFFERENT SAMPLING FRACTIONS
    KRAMMER, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 315 (1-3): : 294 - 298
  • [5] INFLUENCE OF ELECTRIC-FIELD ON CRYSTALLIZATION
    LYCHEV, AP
    RUDENKO, YS
    CHEREMISIN, AI
    [J]. IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII FIZIKA, 1977, (04): : 29 - 32
  • [6] COMPENSATION CONDITION IN SI/U HADRONIC CALORIMETER
    LEMEILLEUR, F
    BORCHI, E
    FRETWURST, E
    LINDSTROEM, G
    LAMARCHE, F
    LEROY, C
    FURETTA, C
    PENSOTTI, S
    RANCOITA, PG
    VISMARA, L
    SEIDMAN, A
    GIUBELLINO, P
    RAMELLO, L
    RICCATI, L
    BARBIELLINI, G
    PENZO, A
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 331 - 333
  • [7] THE INFLUENCE OF ELECTRIC-FIELD ON THE PHOTOGRAPHIC PROCESS
    KALASHNIKOVA, VI
    [J]. JOURNAL OF PHOTOGRAPHIC SCIENCE, 1987, 35 (02): : 55 - 60
  • [8] ELECTRIC-FIELD INFLUENCE ON DENDRITIC GROWTH
    MOTOC, C
    [J]. JOURNAL OF CRYSTAL GROWTH, 1972, 12 (04) : 309 - &
  • [9] INFLUENCE OF ELECTRIC-FIELD ON WEAK LOCALIZATION
    BERGMANN, G
    [J]. ZEITSCHRIFT FUR PHYSIK B-CONDENSED MATTER, 1982, 49 (02): : 133 - 138
  • [10] INFLUENCE OF ELECTRIC-FIELD ON THE CONTROL OF HEMOLYSIS
    RUDRAIAH, N
    VORTMEYER, D
    VEENA, BH
    [J]. PROCEEDINGS OF THE ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, PTS 1-4, 1988, : 531 - 532