This paper discusses the performance of dynamic voltage control devices at the inverters of very weak ac systems. The types of compensation considered are: a) Static var compensator (SVC), b) Synchronous compensator (SC), c) A mix of the two and d) Fixed Capacitors. Although the primary purpose of these compensators is to control voltage at the ac bus, their dynamic performance during system disturbances is a very important factor. The investigation includes the behavior of the various voltage control options under ac and dc disturbances. The paper shows that the SVC has the fastest response for load rejection type of overvoltages, but can cause serious problems with recovery during undervoltages caused by single phase faults. The CIGRE benchmark model for HVdc control studies has been modified and used in this study. In particular the effect of local load has been included.
引用
收藏
页码:1350 / 1358
页数:9
相关论文
共 50 条
  • [1] Dynamic performance of a STATCON at an HVDC inverter feeding a very weak ac system
    Zhuang, Y
    Menzies, RW
    Nayak, OB
    Turanli, HM
    IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (02) : 958 - 964
  • [2] Dynamic performance of HVDC system according to exciter characteristics of synchronous compensator in a weak AC system
    Kim, CK
    Jang, G
    Yang, BM
    ELECTRIC POWER SYSTEMS RESEARCH, 2002, 63 (03) : 203 - 211
  • [3] ANALYTICAL STUDY OF HVDC LINK WITH STATIC VAR COMPENSATORS IN WEAK AC-SYSTEMS
    OOI, BT
    HELLAL, A
    ELECTRIC MACHINES AND POWER SYSTEMS, 1988, 14 (01): : 1 - 16
  • [4] PERFORMANCE EVALUATION OF AN HVDC LINK WITH A CAPACITOR COMMUTATED INVERTER CONNECTED TO A VERY WEAK RECEIVING AC NETWORK
    Khatir, Mohamed
    Zidi, Sid-Ahmed
    Fellah, Mohammed-Karim
    Hadjeri, Samir
    Amiri, Rabie
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2009, 60 (04): : 209 - 214
  • [5] IMPLEMENTATION OF THE HYBRID INVERTER FOR HVDC WEAK AC SYSTEM INTERCONNECTION
    TAM, KS
    LASSETER, R
    IEEE TRANSACTIONS ON POWER DELIVERY, 1986, 1 (04) : 259 - 268
  • [6] INTERCONNECTING A WEAK AC SYSTEM TO AN HVDC LINK WITH A HYBRID INVERTER
    TAM, KS
    LONG, WF
    LASSETER, RH
    ELECTRIC POWER SYSTEMS RESEARCH, 1988, 14 (02) : 121 - 128
  • [7] DYNAMIC PERFORMANCE OF A RADIAL WEAK POWER-SYSTEM WITH MULTIPLE STATIC VAR COMPENSATORS
    RAMOS, AJP
    TYLL, H
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1989, 4 (04) : 1316 - 1325
  • [8] Transient Performance Analysis of Reactive Power Compensators at LCC-HVDC Station Feeding Weak AC System
    Rehman, Atiq Ur
    Gul, Mehr
    Mir, Talha
    Hussain, Syed Mudassir
    Rauf, Zahid
    MEHRAN UNIVERSITY RESEARCH JOURNAL OF ENGINEERING AND TECHNOLOGY, 2021, 40 (04) : 835 - 841
  • [9] THE IMPACT STUDY OF A STATCOM ON COMMUTATION FAILURES IN AN HVDC INVERTER FEEDING A WEAK AC SYSTEM
    Khatir, Mohamed
    Zidi, Sid-Ahmed
    Fellah, Mohammed-Karim
    Hadjeri, Samir
    Flitti, Mohamed
    JOURNAL OF ELECTRICAL ENGINEERING-ELEKTROTECHNICKY CASOPIS, 2012, 63 (02): : 95 - 102
  • [10] Dynamic performance of series multiterminal HVDC during AC faults at inverter stations
    Yang, Xiaobo
    Yuan, Chunming
    Yao, Dawei
    Yang, Chao
    Yue, Chengyan
    2014 16TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'14-ECCE EUROPE), 2014,