IN-VIVO ASSESSMENT OF CATHETER-TIP PO2 SENSOR - SAMPLING LUMEN FABRICATION

被引:0
|
作者
SPENCER, A
ROLFE, P
MURPHY, A
WRIGHT, T
MCKENNA, S
机构
[1] Department of Paediatrics, Biomedical Engineering and Medical Physics, Keele University, North Staffordshire Hospital Trust, Hartshill, Staffs, Thornburrow Drive
关键词
MONITORING; NEONATE; OXYGEN; OXYGEN SENSOR; PRETERM INFANT; UMBILICAL CATHETER;
D O I
10.1007/BF02523034
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Fabrication of the sampling lumen of an intra-arterial PO2 sensor is performed in standard-catheters mechanically or by laser. Clinical evaluation is performed with respect to catheter insertion, complications, accuracy of oxygen sensor data and fibrin deposition on the catheter surface. The success Fate for catheter insertion is 57% for 138 standard and 50% for 74 laser-cut catheters studied. The proportion of catheter failures (blocked or non-reading) is 14% in laser-cut compared with 30% in standard. These differences are not statistically significant at the 5% level. There is no clinically significant difference in sensor accuracy, with 37.5% of results within +/- 0.05 kPa and 80% within +/- 2.0 kPa of simultaneous blood gas values. Drift Is within 0.3 kPa h(-1) for 78% of monitoring time. Significant errors of recalibration occur in 6% of calibrations. Scanning electron micrographs demonstrate a much smaller sampling lumen in the laser-cut group, but no reduction in fibrin deposition at the site of the sampling hole. The low success rate for catheter insertion is a problem because of cost implications. The accuracy of the system is usually sufficient for clinical purposes, provided the calibration is checked every 4 h.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 15 条
  • [1] In vivo assessment of catheter-tip PO2 sensor: Sampling lumen fabrication
    Spencer, A.
    Rolfe, P.
    Murphy, A.
    Wright, T.
    McKenna, S.
    Medical and Biological Engineering and Computing, 1995, 33 (02): : 157 - 162
  • [2] Catheter-tip electrode for continuous measurement of pO2 and pCO2
    Parker, D.
    Delpy, D.
    Lewis, M.
    1600, (16):
  • [3] CATHETER-TIP ELECTRODE FOR CONTINUOUS MEASUREMENT OF PO2 AND PCO2
    PARKER, D
    DELPY, D
    LEWIS, M
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1978, 16 (05) : 599 - 600
  • [4] IN-VIVO COMPARISON OF CATHETER MANOMETER SYSTEMS WITH CATHETER-TIP MICROMANOMETER
    GOULD, KL
    TRENHOLME, S
    KENNEDY, JW
    JOURNAL OF APPLIED PHYSIOLOGY, 1973, 34 (02) : 263 - 267
  • [5] PO2 CATHETER MICROELECTRODE FOR IN-VIVO INTRAVASCULAR USE
    HELLER, ML
    WATSON, TR
    SHAFER, PR
    IMREDY, DS
    ANESTHESIA AND ANALGESIA CURRENT RESEARCHES, 1972, 51 (03): : 453 - &
  • [6] CATHETER-TIP TRANSDUCER FOR IN-VIVO OXYGEN TENSION MEASUREMENTS
    PARKER, D
    PHYSICS IN MEDICINE AND BIOLOGY, 1971, 16 (03): : 539 - &
  • [7] CATHETER-TIP TRANSDUCER FOR CONTINUOUS IN-VIVO MEASUREMENT OF OXYGEN TENSION
    PARKER, D
    KEY, A
    DAVIES, RS
    LANCET, 1971, 1 (7706): : 952 - &
  • [8] RADIO TELEMETRY OF BLOOD PO2 IN-VIVO
    CONWAY, MJ
    PARKER, D
    SOUTTER, LP
    BIOMEDICAL ENGINEERING, 1973, 8 (10) : 428 - 430
  • [9] RADIO TELEMETRY OF BLOOD PO2 IN-VIVO - COMMENT
    RYBAK, B
    BIOMEDICAL ENGINEERING, 1974, 9 (01) : 37 - 37
  • [10] CONTRIBUTION OF IN-VIVO MICROVASCULAR PO2 IN THE CAT CAROTID-BODY CHEMOTRANSDUCTION
    LAHIRI, S
    RUMSEY, WL
    WILSON, DF
    ITURRIAGA, R
    JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (03) : 1035 - 1043