DETERMINATION OF THE POLAR DRUG DIMIRACETAM IN HUMAN PLASMA AND SERUM BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:7
|
作者
TORCHIO, L [1 ]
LOMBARDI, F [1 ]
VISCONTI, M [1 ]
DOYLE, E [1 ]
机构
[1] SMITHKLINE BEECHAM,DEPT METAB & PHARMACOKINET,WELWYN GARDEN CIT AL6 9AR,HERTS,ENGLAND
来源
关键词
D O I
10.1016/0378-4347(94)00564-L
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive and fully automated column-switching HPLC method was developed for the determination of a novel cognition enhancer, dimiracetam, in human plasma and serum. A sample of plasma was ultrafiltered and then directly injected onto a first mu Bondapak C-18 column. The sample was eluted with water. The portion of the eluate (heart-cut) from this column containing the drug was selected and loaded on a second mu Bondapak C-18 column and eluted with water. During the elution of the second column, the first column was automatically rinsed with water-acetonitrile (50:50, v/v) and then equilibrated for a new injection. The total analysis time for each sample was 35 min. This corresponded to a 30% decrease in analysis time compared with the time that would have been needed with a simple run with two mu Bondapak C-18 columns assembled in series. Ultraviolet detection at 200 nm was used to monitor the eluate. The method was fully validated over the quantitation range 27 ng/ml-15 mu g/ml. The applicability of the method was demonstrated by analysis of serum samples from a study performed in human healthy volunteers.
引用
收藏
页码:169 / 177
页数:9
相关论文
共 50 条
  • [1] DETERMINATION OF CEFODIZIME IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING
    BOMPADRE, S
    FERRANTE, L
    LEONE, L
    DEMARTINIS, M
    GINALDI, L
    QUAGLINO, D
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (14): : 2895 - 2909
  • [2] DETERMINATION OF ALFUZOSIN IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING
    CARLUCCI, G
    DIGIUSEPPE, E
    MAZZEO, P
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (18): : 3989 - 3997
  • [3] DETERMINATION OF BROMPERIDOL IN SERUM BY AUTOMATED COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HIKIDA, K
    INOUE, Y
    MIYAZAKI, T
    KOJIMA, N
    OHKURA, Y
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 495 : 227 - 234
  • [4] DETERMINATION OF OXYTETRACYCLINE IN FISH PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND COLUMN-SWITCHING
    EIVINDVIK, K
    RASMUSSEN, KE
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1989, 12 (15): : 3061 - 3071
  • [5] DETERMINATION OF RETINOIDS IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND AUTOMATED COLUMN-SWITCHING
    WYSS, R
    METHODS IN ENZYMOLOGY, 1990, 189 : 146 - 155
  • [6] DETERMINATION OF OXIRACETAM IN PLASMA AND URINE BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LECAILLON, JB
    SOUPPART, C
    LEDUIGOU, F
    DUBOIS, JP
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 497 : 223 - 230
  • [7] DETERMINATION OF NIFEDIPINE IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING COLUMN-SWITCHING TECHNIQUE
    HORVAI, G
    HRABECZYPALL, A
    HORVATH, V
    KLEBOVICH, I
    MIKROCHIMICA ACTA, 1994, 113 (3-6) : 171 - 178
  • [8] DETERMINATION OF PLASMA ADENOSINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING AND FLUOROMETRIC DETECTION
    NITHIPATIKOM, K
    MIZUMURA, T
    GROSS, GJ
    ANALYTICAL BIOCHEMISTRY, 1994, 223 (02) : 280 - 284
  • [9] AUTOMATED-DETERMINATION OF FLUVOXAMINE IN PLASMA BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HARTTER, S
    WETZEL, H
    HIEMKE, C
    CLINICAL CHEMISTRY, 1992, 38 (10) : 2082 - 2086
  • [10] AUTOMATED-DETERMINATION OF MIDAZOLAM IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING COLUMN-SWITCHING
    LAUBER, R
    MOSIMANN, M
    BUHRER, M
    ZBINDEN, AM
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 654 (01): : 69 - 75